background image

CN-1231 with Relay Base

9V DC CARBON MONOXIDE (CO) ALARM 

WITH ALARM RELAY OUPUT

OWNER’S MANUAL 

CAUTION : READ THESE INSTRUCTIONS CAREFULLY BEFORE OP-

ERATING OR SERVICING. PLEASE LEAVE A COPY TO THE END USER.

Te

s t & H us

h

Alarm Fault Power

CARBON

MONOXIDE

ALARM

IMPORTANT ! 

THIS IS NOT A SMOKE ALARM! This CO alarm is designed to detect car-

bon monoxide from ANY source of combustion. It is NOT designed to detect 

smoke, fire, or any other gas.

 

 WARNING ! This product is intended for use in ordinary indoor locations of 

family living units. Do not expose to rain or moisture. The detector will not 

protect against risk of carbon monoxide poisoning when the battery is flat. 

Do cover the alarm when decorating. REMEMBER to uncover the unit when 

decoration is finished (excessive fumes from paints, solvents, cleaning agents, 

etc. may damage or deteriorate sensor). The CO alarm shall not be seen as a 

substitute for proper servicing of fuel-burning appliances, or the sweeping of 

chimneys.

 WARNING ! THIS ALARM CONFORMES TO BSEN50291:2001 MAY 

NOT PROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CAR-

BON MONOXIDE EXPOSURE. IT WILL NOT FULLY SAFEGUARD INDI-

VIDUALS WITH SPECIFIC MEDICAL CONDITIONS. IF IN ANY DOUBT, 

CONSULT A MEDICAL PRACTITIONER.

         

         

© Copyright 2008 Deltronic Security AB

Summary of Contents for CN-1231

Page 1: ...its Do not expose to rain or moisture The detector will not protect against risk of carbon monoxide poisoning when the battery is flat Do cover the alarm when decorating REMEMBER to uncover the unit when decoration is finished excessive fumes from paints solvents cleaning agents etc may damage or deteriorate sensor The CO alarm shall not be seen as a substitute for proper servicing of fuel burning...

Page 2: ... as headaches tightness of chest dizziness fatigue confusion and breathing dif ficulties Because CO poisoning often causes a victim s blood pressure to rise the victim s skin may take on a pink or red cast Extreme exposure to CO can cause brain damage death WARNING EXPOSURE TO HIGH LEVELS OF CARBON MONOXIDE CAN BE FATAL OR CAUSE PERMANENT DAMAGE AND DISABILI TIES COMMON RISKS FOR CO POISONING Tech...

Page 3: ...ting bracket 1 by pushing it upwards and then fasten it onto the ceiling wall with the enclosed screws Connect the battery with ve 2 and ve in the correct position and close the battery cover Connect snap contact to relay 3 base and all connecting wires through the cable entry Fix CO alarm to the relay base 4 with the screws provided Hook the relay base on bracket 5 until it locks in place Now tes...

Page 4: ...ower CO alarm is an early warning device no more no less DO NOT PAINT the alarm WHERENOTTOINSTALLCOALARM Within 1 5m 5 feet of any gas appliance as furnace In any high level of dusty dirty or greasy area In damp or very humid areas outdoor room or next to bathroom at least installed the alarm 3 meters 10 feet away from the bathroom In very cold or very hot area where the temperature could not be l...

Page 5: ...attempt to repair it yourself warranty will be void Note The test push button is independent function with hush button During the normal testing mode the silence feature will not active ADDITIONAL FEATURES The CO alarm comes with the following friendly additional features for use Silence feature This feature can be used to silence nuisance alarms Press test silence button during alarm condition wi...

Page 6: ... function by pressing the test push button until an alarm sounds Self diagnostics Automatically check the sensor every 8s to ensure of correct operating of alarm Low battery warning When the battery power deteriorated the unit will emit one beep with Yellow LED flash every minute to remind user to replace battery Fault warning If a fault is detected the unit will emit 2 beeps with Yellow LED flash...

Page 7: ... 50 ppm 60 min 90 min 100 ppm 10 min 40 min 300 ppm 3 min The battery lasts for over one year About a month before the battery is com pletely flat the alarm emits a short signal with Red LED flashes every minute This is the signal that the battery needs replacement The alarm works as nor mal during this time Always test the alarm after changing the battery Replace battery with GP1604A Duracell MN1...

Page 8: ...detected Flash once every 8 seconds until alarm Memory function indicates the alarm has been activated before not from test button due to whatever reason 8s 8s 1 beep every 8 seconds last for 12 hours Press button once to reset to normal mode Low Battery Warning 1 beep flash every minute 1 min 1min Sensor Fault 2 beeps flash every 8 seconds 8s 8s 8s End of sensor lifetime warning 3 Beeps flash eve...

Page 9: ... applies if the alarms is used in the normal way and is serviced regularly The obligations of this warranty at our discretion shall be limited to the repair or replacement of any part of the alarm and is also conditional on the CO Alarm s not having been tampered with modified or subject to attempted repairs Your statutory rights as a customer are in no way compro mised by this Warranty Limitation...

Reviews: