background image

Parts included with this kit:

Part No.

Description

Quantity

Blower with speed control and 6-foot cord.

1

Instruction Sheet

1

103650-01

Control Knob

1

103651-01

Lock Nut

1

M11084-38

#8 x 3/8" sheet metal screws

5

101629-01

Plastic Hole Bushings

2

101584-05

Wiring Diagram Decal

1

Tools Required

Pliers

Phillips Screwdriver

If any of these pieces are missing or damaged, or if the installation instructions for your fireplace or stove are not included in this manual,
contact the dealer where you purchased this kit or DESA at 1-866-672-6040 for referral information.

(Check your appliance owner’s manual for specific applications and additional instructions.)

 WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong

(grounding) plug for your protection against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle.

For Use With:

Fireboxes: (NL)FB32C, (NL)FB36C, FB42C, (NL)UV32C, CGFB32C, and CGFB36C Series

Vent-Free Fireplaces: VSGF28, VYGF33, VTGF33, VCGF30, VSGF33, FPV33, CGFP28, LFP33 Series,
and (CG)EFP33 Series

Direct-Vent Fireplaces: (E)BDV, BHDV, DVF(E)34, DVFH34, CDV, and CHDV Series

Stoves: CSDBN, SDVB, MSDVB MSTD, CDV, S39T, and S26T Series

INSTALLATION INSTRUCTIONS

GA3750A BLOWER ACCESSORY

For more information, visit www.desatech.com

For more information, visit www.desatech.com

Save this manual for future reference.

Save this manual for future reference.

Summary of Contents for Ga3750a

Page 1: ...r specific applications and additional instructions WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle For Use With Fireboxes NL FB32C NL FB36C FB42C NL UV32C CGFB32C and CGFB36C Series Vent Free Fireplaces VSGF28 VYGF33 VTGF33 ...

Page 2: ...ground wire is tight 6 Locate the plastic hole plug installed in the 3 8 diameter open ing in the lower right side of the firebox front panel see Fig ure 2 Remove the plastic plug and discard 7 Place speed control against inner wall of front panel pushing the plastic control shaft forward through the opening see Figure 3 Figure 1 Removing Screws from Firebox Bottom 8 While supporting speed control...

Page 3: ... concrete firebrick floor from the firebox see Figure 5 Some model fireboxes require that you remove the side and rear panels first Follow the directions below to remove the side and rear fire brick panels for those fireboxes a Using a Phillips screwdriver remove the screw and retainer bracket at the top of the brick liner panel on the left side Care fully remove the left panel from the firebox se...

Page 4: ...st front panel Place control knob provided on shaft see Figure 11 10 Turn on power to duplex outlet if previously turned off per the warning in column 2 page 3 11 Plug in blower power cord a If your firebox is installed as a freestanding unit with an accessory mantel determine whether the power cord will exit the left side or the right side of the firebox Install 1 plas tic bushing provided into t...

Page 5: ...ght your gas appliance with the blower off After about 15 minutes turn the blower on to deliver heated air at the top louvers Theblowerfeaturesavariablecontrolwhichallowsyoutoselectthe speed you desire Note Periodically check the louvers of the firebox and remove any dust dirt or other obstructions INSTALLING BLOWER ACCESSORY IN MODEL SVFBC FREESTANDING STOVE NOTICE Shutoffgasheaterduringthefollow...

Page 6: ...touch the blower wheel while in operation Figure 16 Attaching Blower to Mounting Bracket Blower Mounting Bracket Screws Exhaust Port Ground Wire OPERATING THE BLOWER Lightyourgasappliancewiththebloweroff Afterabout15minutes turn theblowerontodeliverheatedairatthetoplouvers Theblowerfeatures a variable control which allows you to select the speed you desire INSTALLING BLOWER ACCESSORY IN 32 FIREPLA...

Page 7: ... an outlet is not installed in your fireplace you must install the GA3555 Outlet kit with cover in your fireplace which will sup ply a convenient 3 prong grounded electrical outlet for your blower Refertotheinstallationmanualprovidedwiththemodel GA3555 accessory for instructions on wiring the duplex outlet Note Aqualifiedinstallermustmakeallelectricalconnections CAUTION Never touch the blower whee...

Page 8: ...gas appliance with the blower off After about 15 minutes turn the blower on to deliver heated air at the top louvers Theblowerfeaturesavariablecontrolwhichallowsyoutoselectthe speed you desire Note Periodically check the louvers of the fire box and remove any dust dirt or other obstructions NOTICE Shut off gas supply and disconnect heater from gas supply Contact a qualified service person to do th...

Page 9: ...lower Assembly Green Ground Wire CAUTION Never touch the blower wheel while in operation WARNING Failure to position the parts in accor dance with supplied diagrams or failure to use only partsspecificallyapprovedwiththisheatermayresult in damage or personal injury WARNING A qualified service person must con nect fireplace to gas supply Follow all local codes INSTALLING BLOWER ACCESSORY IN FREESTA...

Page 10: ...t against the plate Place control knob provided onto shaft see Figure 25 9 Replace plate containing switches and tighten screws securely 10 Plug in blower power cord a If your fireplace system is installed as a freestanding unit with an accessory mantel determine whether the power cord will exit the left side or the right side of the firebox Install one plastic bushing provided into the 1 1 2 hole...

Page 11: ...ure to position the parts in accor dance with supplied diagrams or failure to use only partsspecificallyapprovedwiththisheatermayresult in damage or personal injury 13 Connect or reconnect gas supply following instructions given in the owner s manual supplied with your fireplace WARNING A qualified service person must con nect fireplace to gas supply Follow all local codes Figure 26 Installing Pla...

Page 12: ...n visit www desatech com For more information visit www desatech com 108319 01 REV B 09 03 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Technical Service Department 1 866 672 6040 www desatech com 108319 01 NOT A UPC ...

Reviews: