background image

Figure 1. High Output Overhead Ionizer

Description

The Desco 40" High Output Overhead Ionizer is designed to 

neutralize electrostatic charges over a large work area.  The 

unique active feedback and balance circuit automatically 

ensures and maintains the unit’s ion offset voltage balance, 

despite variations in line voltage, air speed or emitter 

electrode condition.  The ionizer’s feedback circuit also 

gives an audible and visual alarm indication when a circuit 

malfunction has been detected.  The overhead mounting 

design of this ionizer allows it to provide maximum coverage 

without consuming valuable work bench space.  The need 

for maintenance is minimized, while maximum neutralization 

efficiency and overall performance is attained.
This overhead ionizer is unique - it comes equipped with 

two factory installed lights and three heaters.  The lights 

are on continuously whenever the ionizer is turned on and 

allow for better vision at the workstation.  The heaters 

are activated by a switch on the face of the ionizer.  The 

heaters will raise the temperature of the output air to about 

10° above ambient.  The heaters are only to offset the chill 

factor of the moving air.  They are not intended to warm the 

workstation.
Ionizers are useful in preventing electrostatic charge 

generation, ElectroStatic Discharge, ElectroStatic Attraction, 

as well as preventing equipment latch-up and safety related 

shock.  Per ANSI/ESDS20.20-2007 section 8.3 “In order 

to mitigate field-induced CDM [Charged Device Model] 

damage, the ESD program shall include a plan for the 

handling of process-required insulators. If the field exceeds 

2,000 volts/inch, steps shall be taken to either: A) Separate 

the insulator from the ESD-sensitive device by a distance 

of 30 cm (12 inches); or B) Use ionization or other charge 

mitigating techniques to neutralize the charge.”

Ionization is used to neutralize charges on process 

necessary insulators and isolated semiconductors.  Some 

examples of process necessary insulators are: the PC 

board itself, plastic test stands, plastic housing where 

a PCB may be mounted, as well as computer monitor 

TB-3006

 March 2013 Page 1 of 4

High Output Overhead Ionizer

Installation, Operation and Maintenance

screens and regular cleaning wipes.  Examples of floating 

or isolated conductors are: loaded PCB mounted in a 

stand where the pins are not contacting the dissipative 

workstation.  Ionization is not effective on items that have 

large capacitance, like people and carts; however, ionizers 

should be considered as a method for charge neutralization 

in cases where grounding cannot be achieved.
“Ionizers should be considered as a method for charge 

neutralization in cases where grounding cannot be 

achieved.” …“Air ionization can neutralize the static charge 

on insulated and isolated objects by producing separate 

charges in the molecules of the gases of the surrounding 

air. When a static charge is present on objects in the work 

environment, it will be neutralized by attracting opposite 

polarity charges from the ionized air.” (EN 61340-5-2 

paragraph 5.2.9)
This ionizer is NIST calibrated and comes equipped with 

universal IEC cord connectors.

© 2013 DESCO INDUSTRIES INC.

Employee Owned

TECHNICAL BULLETIN TB-3006

 

Model  Voltage / Hz 

Light & Heater 

IEC Cord

 

60600

 

120 / 50-60 

Yes 

7' 6"

IONIZER SELECTION

ANSI/ESD S20.20 paragraph 6.1.1.2. ESD Control Program 

Plan Guidance states: “The Plan should include a listing of 

the specific type of ESD protective materials and equipment 

used in the Program.”  When selecting an ionizer life cycle 

costs should be considered including: equipment cost, 

installation cost, and operation and maintenance cost.

24 IN.

24 IN.

48 IN.

OPTIMUM

PERFORMANCE 

ZONE

Figure 2. Area of optimum charge neutralization

The unit provides better coverage without using excessive 

bench space. The ionizer’s discharge times (neutralization 

efficiency) is optimal at approximately 12" to 24" above the 

work surface, and will drop off as the distance from the unit 

increases.

*Never use incandescent lamps in the 

60600

 ionizer. 

Contact Desco Customer Service at (909) 627-8178 for 

lamp replacement information.

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

Made in the

United States of America

Summary of Contents for 60600

Page 1: ...c housing where a PCB may be mounted as well as computer monitor TB 3006 March 2013 Page 1 of 4 High Output Overhead Ionizer Installation Operation and Maintenance screens and regular cleaning wipes Examples of floating or isolated conductors are loaded PCB mounted in a stand where the pins are not contacting the dissipative workstation Ionization is not effective on items that have large capacita...

Page 2: ...1 3 1 Compliance Verification Plan Requirement states Test equipment shall be selected to make measurements of appropriate properties of the technical requirements that are incorporated into the ESD program plan And paragraph 6 1 3 2 Compliance Verification Plan Guidance states In addition to internal audits external audits Organization and supplier of ESDS items should be performed to ensure comp...

Page 3: ...circuit will cause the blue LED to flash until the problem is corrected See the maintenance section for recommended maintenance procedures 2013 DESCO INDUSTRIES INC Employee Owned Figure 6 Cleaning the emitters and fan guards Emitter pin cleaning is very simple and should be done frequently TURN THE IONIZER OFF Blow off contaminants on the emitter assemblies and fan guards with clean dry air If th...

Page 4: ...8 Chino CA or 781 821 8370 Canton MA for Return Material Authorization RMA and proper shipping instructions and address You should include a copy of your original packing slip invoice or other proof of pur chase date Any unit under warranty should be shipped prepaid to the Desco factory Warranty repairs will take approximately two weeks If your unit is out of warranty Desco will quote repair charg...