background image

distance of 30 cm (12 inches); or B) Use ionization or other 
charge mitigating techniques to neutralize the charge.” 
(ANSI/ESD S20.20-2007 section 8.3)

“The primary method of static charge control is direct 
connection to ground for conductors, static dissipative 
materials, and personnel.  A complete static control 
program must also deal with isolated conductors that cannot 
be grounded, insulating materials (e.g., most common 
plastics), and moving personnel who cannot use wrist or 
heel straps or ESD control flooring and footwear.

Air ionization is not a replacement for grounding methods.  
It is one component of a complete static control program.  
Ionizers are used when it is not possible to properly 
ground everything and as backup to other static control 
methods.  In clean rooms, air ionization may be one of the 
few methods of static control available.” (ESD Handbook 
ESD TR20.20 Ionization, section 5.3.6.1)

“All ionization devices will require periodic maintenance for 
proper operation.  Maintenance intervals for ionizers vary 
widely depending on the type of ionization equipment and 
use environment.  Critical clean room uses will generally 
require more frequent attention.  It is important to set-up 
a routine schedule for ionizer service.  Routine service is 
typically required to meet quality audit requirements.” (ESD 
Handbook ESD TR20.20 section 5.3.6.7 Maintenance / 
Cleaning)

Packaging

1  Chargebuster Overhead Ionizer
1  Hanging Kit
1  Power Cord
3  Emitter Point Cleaners
1  Certificate of Calibration

Installation

Input voltage is selected with the two internal jumpers on 
JH1.  For 110 volt jumper setting, a jumper must be in place 
shorting pin 1 to 2 and another shorting pin 3 to 4 (see 
Figure 3).  For 220 volt jumper setting, a single jumper must 
be in place shorting pin 2 to 3 only (see figure 4). Make 
sure setting is correct before applying power.

Note:

 Unit shipped set at 110V

Before installing the unit, verify that the AC outlet is properly 
connected to ground.  The unit must have a good ground 
to maintain proper offset voltage balance.  Install the unit in 
the desired location, making sure that the airflow will not be 
restricted.  Be sure the “OFF / ON” switch located on the 
rear of the unit is in the OFF position.  Plug the power cord 
into the unit and then into the appropriate AC power source.

TB-3031

 May 2010 Page 1 of 4

Figure 2.  Desco 

60640

 Chargebuster Overhead Ionizer

Description

The Chargebuster

®

 overhead ionizers are steady state DC 

ionizers designed to cover 2 foot by 5 foot (

60473

) or 2 

foot by 4 foot (

60640

for use in ESD sensitive work areas: 

calibration, test, final assembly, or repair procedures.  The 
specially designed 3-speed fan modules create better 
coverage, consistent offset voltage (±10 Volts), and superior 
discharge times(<3 seconds) tested per ANSI/ESD STM 
3.1.  The Chargebuster

®

 overhead ionizers are equipped 

with a Auto-Feedback system, that continually optimizes the 
performance and will automatically shut down the and alarm 
if/when supply voltage drops to the ionizer.  The ionizers 
can be used with 110V or 220V power sources.

“Necessary non-conductors in the environment cannot 
lose their electrostatic charge by attachment to ground. 
Ionization systems provide neutralization of charges on 
these necessary non-conductive items (circuit board 
materials and some device packages are examples of 
necessary non-conductors).  Assessment of the ESD 
hazard created by electrostatic charges on the necessary 
nonconductors in the work place is required to ensure 
that appropriate actions are implemented, commensurate 
with risk to ESDS [ESD sensitive] items”. (ANSI/ESD 
S20.20-2007 Foreword)

“In order to mitigate field-induced CDM [Charged Device 
Model] damage, the ESD program shall include a plan for 
the handling of process-required insulators.  If the field 
exceeds 2,000 volts/inch, steps shall be taken to either: A) 
Separate the insulator from the ESD-sensitive device by a 

TECHNICAL BULLETIN TB-3031

Made in America

© 2010 DESCO INDUSTRIES INC.

Employee Owned

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: 

Desco.com

Figure 1.  Desco 

60473

 Chargebuster Overhead Ionizer

Chargebuster

®

 Overhead Ionizer

Operation, Installation, and Maintenance

Summary of Contents for Chargebuster

Page 1: ...nce Install the unit in the desired location making sure that the airflow will not be restricted Be sure the OFF ON switch located on the rear of the unit is in the OFF position Plug the power cord into the unit and then into the appropriate AC power source TB 3031 May 2010 Page 1 of 4 Figure 2 Desco 60640 Chargebuster Overhead Ionizer Description The Chargebuster overhead ionizers are steady stat...

Page 2: ... alarm will sound continuously If the ionizer enters shutdown mode it must be turned OFF and then back ON to reset the unit NOTE The AC power cord MUST be disconnected before the unit is disassembled for maintenance The emitter electrodes should be cleaned using the included cleaners or a swab damp with isopropyl alcohol First turn the unit OFF and unplug the power cord Then remove each fan grill ...

Page 3: ...cation of ESD Protective Equipment and Materials The most accurate tool to use for this is a Charged Plate Monitor Alternatively a portable battery operated Ionization Test Kit can be used Per ESD TR 53 ANNEX A Test Frequency The objective of the periodic test procedures listed in this document is to identify if significant changes in ESD equipment and materials performance have occurred over time...

Page 4: ...dentify each ionizer and setup a compliance Verification Maintenance Calibration schedule If the ionizers all test good the data can justify lengthening the calibration period If ionizers require adjustment the calibration period should be shortened Although ESD TR53 does not advise a test frequency JESDD625 A Revision of EIA 625 recommends ionizers be tested semiannually noting to use S3 1 except...