FIRE RATED BOLT
INSTALLATION INSTRUCTIONS
F1000V LBR
2017.04
A
IDENTIFICATION OF PARTS
5/32”
3/16”-24
METAL
B
TOOLS REQUIRED
STRIKE HOLE PLUG
(FOR STRIKE DOOR)
BOLT
PLASTIC CAP
3/16” x 1/2”
FLAT HEAD
MACHINE SCREWS
3/16” x 5/8”
FLAT HEAD,SELF TAPPING
MACHINE SCREWS
5/32” x 3/4”
FLAT HEAD
WOOD SCREWS
HEAD COVER PLUG
STEP 3:INSTALL FIRE RATED BOLT
1.Insert bolt and use the provided screws to secure bolt.
2.3/16” x 1/2” flat head machine screws and 3/16” x 5/8” flat head,
self-tapping machine screws for metal door use.
3.5/32” x 3/4” flat head wood screws for wood door use.
HEAD COVER
HEAD COVER PLUG
HEAD COVER PLUG
INSTALLED
STEP 4:INSTALL STRIKE HOLE PLUG
1.Insert hole plug into the 1” hole in strike door leaf.
2.Self adjusting tabs on the hole plug will lock in place to secure
the plug.
STEP 5:REVIEW INSTALLATION
1.Close both doors and verify
fire rated bolt
and strike hole are lined up.
2.Be sure the door gap directly in front of the
fire rated bolt
is not covered with a door edge guard or
any other similar type of device.
REMARKS:
1.Refer to F1000V
devices
Installation Instructions for
further
details.
2.Before installing head cover,insert head cover plug into bottom side of head cover first.
(Packed with LBR device)