background image

READ AND SAVE THESE INSTRUCTIONS

FOR CEILING FAN PARTS AND SERVICE, 

CALL 1-877-902-5588 

FAN RATING AC 120V. 60Hz UL LISTED MODEL : AC-552MP3

MODEL: 52SH4L5-PW

CEILING FAN OWNER'S MANUAL

Distinctive      Lighting and Ceiling Fans

Summary of Contents for 52SH4L5-PW

Page 1: ... SAVE THESE INSTRUCTIONS FOR CEILING FAN PARTS AND SERVICE CALL 1 877 902 5588 FAN RATING AC 120V 60Hz UL LISTED MODEL AC 552MP3 MODEL 52SH4L5 PW CEILING FAN OWNER S MANUAL Distinctive Lighting and Ceiling Fans ...

Page 2: ...se function on this fan press the reverse button while the fan is running 8 Avoid placing objects in the path of the blades 9 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most cleaning 11 After mar...

Page 3: ...ire nuts k Transmitter holder 2 mounting screws l 9 Volt battery m Extra switch housing n Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 16 fiber washers 16 3 Balance Kit Philips screw driver Blade screw driver 11 mm wrench Step ladder Wire cutters 2 2 TOOLS AND MATERIALS REQUIRED b a c d e f g h i ...

Page 4: ...eight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet box...

Page 5: ...en through the ball downrod Fig 7 NOTE Do not install the coupling cover if you plan to use the 4 downrod Step 7 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 7 Carefully insert the hitch pin through the holes in the collar and downrod Be careful not to jam the pin against the wiring inside the downrod Insert the locking pin through the h...

Page 6: ...onnect the white wire from the fan to the white wire marked TO MOTOR N from the receiver Connect the blue wire from the fan to the blue wire marked For Light from the receiver Secure the wire connections with the plastic wire nuts provided Figure 10 Figure 9 Figure 11 Code switch Receiver Hanger bracket ON ON CHANGING THE DOWNROD OPTIONAL NOTE Your fan comes with a 6 downrod attached to the hanger...

Page 7: ...nsmitting unit for proper signal transmission between the transmitting unit and the fan s receiving unit 7 FINISHING THE INSTALLATION Step 1 Tuck connections neatly into ceiling outlet box Step 2 Slide the canopy up to ceiling and over the two screws on hanger bracket Rotate canopy clockwise next while holding the canopy with one hand slide the canopy cover over the screws and rotate clockwise unt...

Page 8: ...to motor using the screws supplied Fig 14 Figure 14 Figure 15 9 INSTALLING THE MOUNTING PLATE 1 Remove the 1 of 3 screws from the mounting ring and loosen the other 2 screws Do not remove 2 Place the key holes on the mounting plate over the 2 screws previously loosened from the mounting ring turn mounting plate until it locks in place at the narrow section of the key holes Secure by tightening the...

Page 9: ...housing then install the light kit assembly onto the mounting plate with 3 screws provided Be sure to tighten all screws Fig 16 11 INSTALLING THE LIGHT BULBS GLASS SHADES 1 Remove the lock ring from the socket by turning the lock ring counter clockwise Until it unlocks Insert the glass into the glass holder and turn the lock ring clockwise to tighten the glass Repeat for the remaining glass Fig 17...

Page 10: ...ixture for future use 2 Install the wire harness into the empty switch box by placing the reverse module and capacitor inside the empty switch box with self adhesive tape Fig 18 3 Tuck the wire harness into the switch box 4 Remove the screws from the mounting plate under the fan motor Raise the switch box to the mounting plate until the holes in switch box and mounting plate line up Reinsert the s...

Page 11: ...ess and release the button to turn the light ON or OFF Press and hold the button to set the desired brightness The light key has an auto resume it will stay at the same brightness as the last time it was turned off D The REV button is used to set the fan forward or reverse press the button forward for warm weather or reverse for cool weather LOW OFF HI MED REV 12 INSTALLING THE BATTERY Install 9 v...

Page 12: ...reverse button while the fan is running Warm weather Forward A downward airflow creates a cooling effect as shown in Fig 22 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off the ceiling area as shown in Fig 23 This allows you to set your heating unit on a cooler setting without affecting your com...

Page 13: ...6 Do not connect the fan with a wall mounted variable speed control s 7 Make sure the upper canopy is a short distance from the ceiling It should not touch the ceiling 1 Check that all blade and blade arm screws are secure 2 Most fan wobbling problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distan...

Reviews: