For additional information on system commands, see the DS7080iP-32 User’s Guide P/N 39425

Reference Guide

for the

DS7080iP-32 Two Partition

 Control/Communicator

Turning Off (Disarming) your System

[PIN] + [Off]

Commands for other System Features

Chime Mode

[PIN] + [#] [7]

Zone Test

[PIN] + [#] [8] [1]

Event History Readback

[PIN] + [#] [8] [9]

Battery Test

[PIN] + [System Reset]

Communicator Test

[PIN] + [#] [8] [2]

Fire Reset

[PIN] + [System Reset]

Fire Trouble

[PIN] + [Off] to silence, [PIN] + [System Reset] to clear

Remote Program Dial-out

[PIN] + [#] [8] [3]

Remote Program Answer

[PIN] + [#] [8] [6]

Local Battery/Sounder Test

[PIN] + [#] [8] [5]

Error Display

[PIN] + [#] [8] [7]

Error Display Reset

[PIN] + [System Reset]

Clear Zone Bypass

[PIN] + [Bypass] [*] to clear

Access Control

[Access Control PIN] + [Off]

Keypad Quick Reference Guide

Turning On (Arming) your System

[PIN] + [On]
[PIN] + [No Entry] [Perimeter Only]
[PIN] + [Perimeter Only]
[PIN] + [No Entry] [On]
[PIN] + [#] [4]
[PIN] + [Arming Sequence] + [Bypass]

[PIN] + [Bypass] + [2-digit Zone number]

[PIN] + [#] [9] [9]
[PIN] + [OFF]

Normal Arming

Perimeter Arming, no entry delay
Perimeter Arming, with entry delay
Maximum Security Arming
Custom Arming
Force Arming

Zone Bypass

Set Delayed  Arming
Delay Auto Arm by 15 Minutes

Change Partitions

[PIN] + [#] [#]

Armed

Status

Power

Fire

1

2

3

4

5

6

7

8

9

0

*

#

On

No

Entry

System

Reset

Bypass

Only

Perimeter

Off

Armed

Status

Power

Fire

1

2

3

4

5

6

7

8

9

0

*

#

On

No

Entry

System

Reset

Bypass

Only

Perimeter

Off

Perimeter

Supervisory
Bell Silenced

Trouble

1 2 3 4 5 6 7 8

Ready To Arm

DS7447

DS7445

Downloaded from:

 http://www.guardianalarms.net

Summary of Contents for DS7080iP-32

Page 1: ...ne Bypass PIN Bypass to clear Access Control Access Control PIN Off Keypad Quick Reference Guide Turning On Arming your System PIN On PIN No Entry Perimeter Only PIN Perimeter Only PIN No Entry On PIN 4 PIN Arming Sequence Bypass PIN Bypass 2 digit Zone number PIN 9 9 PIN OFF Normal Arming Perimeter Arming no entry delay Perimeter Arming with entry delay Maximum Security Arming Custom Arming Force...

Page 2: ... DS7080iP 32 23 9 1 Address 001 EX8 Zone Expansion Module Control 24 9 2 Address 002 General Control 24 9 3 Address 003 User Controls 25 9 4 Address 004 Programmer and Master Codes 25 9 5 Address 005 Cross Zoning 25 9 6 Address 006 Trip window 25 9 7 Address 007 Keypad Assignment 26 9 8 Address 008 Language and Arming Controls 26 9 9 Address 009 Output Programming 26 9 10 Address 010 Time Delays 2...

Page 3: ...r Partitioned Systems 43 10 3 Programming the DS7080iP 32 43 10 3 1 Household Fire Alarm 43 10 3 2 Grade A Household Burglary Alarm 43 10 3 3 Local Burglary Alarm 43 10 3 4 Police Station Connection 44 10 3 5 Central Station Burglary Alarm 45 10 4 Using the Ademco AB 12 Bell Housing 46 11 0 Report Programming Suggested Values 47 11 1 Personal Dialing and Pager Format 47 11 2 Pager Format 47 11 3 S...

Page 4: ...ansion zones using EX8 Zone Expansion Module Each EX8 adds 8 additional zones Up to three EX8 modules can be added to the system On Board Zone Response Time 300 milliseconds 1 6 Keypads 1 6 1 DS7443 Keypad Total number of keypads 4 Keypads Maximum wire length each run 400 feet 122m Maximum wire length total 1600 feet 488m in system Wire type 4 conductor unshielded 22 AWG 0 8mm or 18 AWG 1 0mm Tele...

Page 5: ... 5 225 AH 6 025 AH 10 825 AH 11 625 AH 13 385 AH Max Standby for 4 hours 590 mA 1 0 A 1 0 A 1 0 A 1 0 A 1 0 A Max Standby for 8 hours 230 mA 530 mA 640 mA 1 0 A 1 0 A 1 0 A Max Standby for 24 hours X 100 mA 130 mA 330 mA 360 mA 440 mA Max Standby for 48 hours X X X X 120 mA 160 mA Max Standby for 60 hours X X X X X 100 mA Battery AH 20 Storage 0 375 AH s Alarm The following table is the derated ba...

Page 6: ...or 18 AWG 1 0mm Option Bus Quick Connect TYPICAL BURGLAR AND FIRE WIRING Typical 2 wire smoke detector wiring for a list of compatible 2 wire smoke detectors see Technical Service Note P N 41150 EOL Resistor Smoke Detector Zone 1 Only 14 15 Typical 4 wire smoke detector wiring For example Detection System s DS250 in an MB4W base EOL Resistor EOLRelay Smoke Detector EOL Resistor EOLRelay Smoke Dete...

Page 7: ...DS7080iP 32 Reference Guide Copyright 2001 Detection Systems Inc P N 39818D Page 7 4 0 System Worksheet ...

Page 8: ...Page 8 P N 39818D Copyright 2001 Detection Systems Inc DS7080iP 32 Reference Guide 4 0 System Worksheet continued ...

Page 9: ...9 Keyswitch On Off A Fire Zone with Verification B Fire Zone without verification C Perimeter Follower Homeguard F 4 Cross zoning across partitions is not supported 5 Cross zoning with different zone types is not supported 6 If the trip window is 000 the cross zone time will be the duration of the arm cycle of the crossed non 24 hour zones 24 hour zones will have a 24 hour duration Trouble Zone TR...

Page 10: ...lay time This zone is bypassed when arming only the perimeter Interior Home Away This zone becomes an active interior entry exit follower when the system is armed and an entry exit delay zone is violated during the exit delay time If the system is armed and an entry exit delay zone is not violated this zone will be bypassed This zone is bypassed when arming only the perimeter Interior Instant This...

Page 11: ...condition to activate It will remain activated until the system is disarmed or the bell cut off time expires This output is intended to activate alarm bells and sirens but provides a delay to allow the user to silence the system before it activates Fire Zone This is an output programmed to activate when a Fire Zone is in an alarm condition It will remain activated until the system is disarmed rese...

Page 12: ... be enabled before Module 3 can be used Be sure to set each module with a different address Failure to do so will result in improper communication between the EX8 and the panel 6 6 Emergency Key Programming Fire Key A Key The emergency key at the bottom left of the keypad entry area is the Fire Key If programmed the key will activate a fire alarm when pressed for 2 seconds It may be programmed for...

Page 13: ...o be force armed When force arming the user must enter the usual arming command followed by the Bypass key This automatically bypasses zones that are violated and programmed as bypassable Fire zones keyswitch zones and non bypassable zones can not be force armed Not available in UL Listed systems 6 14 Report Programming Reports For pulse formats reports are programmed by entering data in the repor...

Page 14: ...stem Trouble Restoral This report is sent when all system trouble conditions restore Exit Error This report is sent if an exit error occurs An exit error occurs when an entry exit zone is still violated at the end of the exit delay If this happens the entry delay will begin If the system is not disarmed before the entry delay expires an alarm report for the affected zone will be sent and the Exit ...

Page 15: ...must be made by manufacturer and not by the user To guard against accidental disconnection there is ample room to mount the Telco jack to the inside of the Control cabinet The operation of this Control may also be affected if events such as accidents or acts of God cause an interruption in telephone service 6 18 Canadian Dept of Communications General Installation Requirements Notice The Canadian ...

Page 16: ... accounted for Provide a barricade between family members and fire smoke and toxic gases e g close all bedroom doors before retiring Children should be instructed on opening their bedroom windows and exiting safely from the building If exiting is not possible they should be taught to stay at the open window and shout for help until it arrives In the event of a fire alarm after retiring wake the ch...

Page 17: ...rom the Master Code Programming Mode approximately 15 seconds after the last keystroke If the control panel loses power the date will need to be set again 7 3 Setting the Time It is recommended that this procedure be performed at a DS7447 Keypad No visual clues will be given from a DS7445 keypad Steps to Change the Time Command Sequence If Accepted the Display Reads 1 Enter the Master Code Program...

Page 18: ... perform system tests system reset and view history PIN 01 must be a master code and must have authority 0 Any or all PINs may be master codes 1 Unlimited Can enter all commands bypass arm disarm system reset and perform system tests Can not change PINs 2 General Can bypass arm and disarm Can not change PINs perform system reset or enter the 7 or 8 functions 7 4 Personal Identification Numbers 7 4...

Page 19: ...ur format You may move the cursor left or right by pressing the A Fire or C Panic keys When you have completed the time entry press The display will then advance to the next day You may exit the Set Auto Arm Time Mode at any time by pressing once The system will also exit the Auto Arm Time Mode after the time is programmed for Saturday Samples of times 12 midnight 2400 12 noon 1200 12 01am 0001 12...

Page 20: ...Residential Mode a PIN is not required for these commands Battery Trouble and Communicator Err displays must be cleared by the System Reset command sequence even after the problem has been remedied These displays will not self clear All the other error displays will self clear from the keypads once the problem has been remedied 8 DS7447 Pt Exp Mssng XXX DS7445 LED 8 turns on steady The EX8 Zone Ex...

Page 21: ...ne Test Mode enter your PIN followed by If in Residential Mode a PIN is not required for this command 7 10 Battery Sounder Test This chart explains the procedure for performing a battery test If a power failure occurs your control panel has a built in battery that will continue to power the control panel for many hours The control panel automatically recharges the battery when power is restored In...

Page 22: ...023 before it fails this test If in Residential Mode a PIN is not required for this command 7 12 Event History Readback This chart explains the procedure for performing an Event History Readback The History Buffer stores the last 100 events in memory The DS7447 can display all of these events The DS7445 will only display those zones 1 8 that have alarmed Type of Test Command Sequence What Will Hap...

Page 23: ...L 6 M N O 8 T U V 7 P R S 9 W X Y Move Cursor Left Move Cursor Right Don t Accept Hold for 2 seconds to exit Accept Value 0 Q Z 4 5 6 7 8 9 Entry Perimeter No Only 9 0 Programming the DS7080iP 32 Most control panel functions are controlled using a single program address Some functions are grouped into one address For example The keypad emergency keys are programmed in Address 028 The first data di...

Page 24: ...ral station Closing Ring Back If programmed the keypad sounders and Bell will activate for 2 seconds after the system is armed and the closing report is successfully sent This requires the Closing Ring Back and Closing Reports to be programmed Swinger Shunt If selected a zone can only alarm or trouble up to three times per armed period After the third alarm or trouble the zone will be bypassed and...

Page 25: ...le 123456 will become 1234 If two or more six digit PINs have the same first four digits a PIN conflict will exist if changed to four digits Changing from four to six digit PINs will add two zeros to the end of the existing PINs Example 1234 will become 123400 It is recommended that when changing the PIN length that all PINs be reprogrammed 9 4 Address 004 Programmer and Master Codes The display w...

Page 26: ...ystem messages are displayed in English or another language Selections for other languages will vary depending on the model ordered Arming Mode Determines if a PIN is required for arming the system Commercial Always requires a PIN for arming Quick Arm Allows the use of ON to arm the system Not available in Partitioned systems Residential Allows the use of the key in place of the PIN number for all...

Page 27: ... delays as well as the bell cutoff times If a bell cutoff time is programmed with the maximum value of 099 then the actual cutoff time will be 30 seconds 9 11 Address 011 Report Controls Address 011 is used to determine report routing Use options 0 3 for Non partitioned systems Do not select Options 4 through C if No Partitioning is selected in Address 002 Digit 6 ...

Page 28: ...econd Dialer Delay DIALER DELAY OF 15 SECONDS ON 24 HOUR BURGLAR AND FIRE ALARMS 0 No Dialer Delay 1 15 Second Dialer Delay 0 WDSRP BAUD RATE 0 110 Baud 1 300 Baud Required on PBX systems The letters used for the ring counts are A 10 rings B 11 rings C 12 rings D 13 rings E 14 rings F 15 rings 9 13 Address 013 Partition 1 Account Codes 1 Account codes are programmed from left to right If programmi...

Page 29: ...DS7080iP 32 Reference Guide Copyright 2001 Detection Systems Inc P N 39818D Page 29 9 15 Address 015 Phone 1 Format 9 16 Address 016 Phone 2 Format ...

Page 30: ... number from the display window enter 5 in all the digits 9 18 Address 023 Dial Attempts Dial Attempts determines the maximum number of times the control panel will attempt to contact the central station on each programmed phone number before a Comm Fail is alerted After all dial attempts are made the panel will log a communications failure It will then wait 30 minutes and attempt to dial again re...

Page 31: ...il report will be sent along with this report If the AC power restores during this delay period the AC Fail report will not be sent 9 22 Address 027 History Controls History Controls determines what events are stored in the panel s event history 9 23 Address 028 Special Keys This address is used to determine the alarm output when the emergency keys are pressed DEFAULT FIRE KEY A SPECIAL EMERGENCY ...

Page 32: ... with the panel and never have entry or exit delays Violation of this type of zone will cause an intrusion alarm 24 Hour This is a zone programmed to activate when its loop is faulted even if the system is disarmed An alarm on a 24 hour zone fire or intrusion will be silenced by entering a disarm code whether the control is armed or not If the 24 hour zone restores and alarms again the alarm will ...

Page 33: ...eyswitch toggle feature will be used Arming Disarming from a keypad by users with access to both partitions will cause the keyswitch partition to toggle between Armed and Disarmed If keyswitch operation is desired in a partitioned system avoiding the use of keypads is recommended If Force Arming for Keyswitch Zones is enabled Address 038 041 Keyswitch Toggle will force arm a Not Ready zone Keyswit...

Page 34: ...ng Alarm Output Invisible This is a zone programmed not to have an alarm output or an alarm display at any keypad when activated An alarm signal will be sent but the keypad display will not indicate an alarm while this zone is violated Invisible alarm zones are recommended for holdup alarms Silent This is a zone programmed to activate the visual display at the kaypad but not audible signals If thi...

Page 35: ... Arming Programming allows the 4 key sequence on the keypad to be used for custom arming The programming determines which zones will be bypassed not armed during custom arming Zones programmed as No Bypassing Allowed and Fire zones cannot be bypassed when custom arming 9 30 Address 050 051 052 053 Zone Partition Assignment Zone Partition Assignment is used to determine what Zones belong to which P...

Page 36: ...ill only send 15 Pulsed formats 3 1 3 1 with parity and 4 1 need a 0 for the second digit and cannot send user numbers If 4 1 is selected placing a digit other than 0 in the second digit will force the communicator to change to a 4 1E format A non zero in the second digit location indicates an extended 3 1E 3 1E w parity or 4 2 format Fixed Report Formats Contact ID SIA High Speed 4 9 have well de...

Page 37: ... 062 063 064 065 Zone Trouble Reports Two Digits 00 through FF 9 34 Addresses 066 067 068 069 Trouble Restoral Reports Two Digits 00 through FF 9 35 Addresses 070 071 072 073 Zone Bypass Reports Two Digits 00 through FF 9 36 Addresses 074 075 076 077 Bypass Restoral Reports Two Digits 00 through FF ...

Page 38: ...iP 32 Reference Guide 9 37 Address 078 Open Close Reports 9 38 Address 079 AC Battery Reports 9 39 Address 080 Remote Local Programming Reports 9 40 Address 081 Exit Error Recent Closing System Trouble System Trouble Restoral Reports 9 41 Address 082 Test Reports ...

Page 39: ...the Programmer s Mode 9 8 7 6 0 or 9 8 7 6 5 4 0 if six digit codes are selected Enter the Program Address 0 8 3 followed by Enter 2 for the letter A then press the right arrow key to continue with the next letter Enter 2 twice for the letter B the press the right arrow key for the next letter Enter 2 three times for the letter C then press the right arrow key for the next letter Enter 1 until you...

Page 40: ...de 9 45 Address 119 Point Expansion Module Tamper Report 9 46 Address 120 Point Expansion Module Tamper Restoral Report 9 47 Address 121 Point Expansion Module Fault Report 9 48 Address 122 Point Expansion Module Fault Restoral Report 9 49 Address 123 Octal Relay Control and Reports ...

Page 41: ... panel will result in the loss of all custom programming This includes Zone programming Report programming Keypad programming only the keypad set as Option Bus Address 1 will function Alpha programming Telephone numbers and Account codes If the digit 1 is entered into Address 124 all programming information will be lost and cannot be recovered ...

Page 42: ...isted 10 2 Installation Considerations In order to meet UL requirements the system must be configured as described in Section 10 The maximum standby battery capacity is 21 AH 12 VDC The total nominal current must not exceed 1 2 A in alarm and 200 mA in standby The control must be mounted indoors and within the protected area Enclosure tamper switches if used must be connected to a 24 hour zone Gro...

Page 43: ...med AC Failure Report Program Address 079 digits 5 6 must be programmed B Timer Programming Bell Cutoff Times Program Address 010 digits 10 15 must be programmed for not less than 4 minutes C Zone Programming Fire zones must be programmed for alarm on short trouble on open not be cross zoned or be part of custom arming D Alarm Output Programming Alarm Output Program Address 009 digit 1 must be pro...

Page 44: ...8 digits 1 2 must be programmed Close Report Program Addresses 011 digit 1 and 078 digits 3 4 must be programmed 24 Hour Check In Reports Program Addresses 082 digits 1 4 024 and 025 all digits must be programmed 2 Timer Programming Entry Exit Delay Times Program Address 010 digits 1 9 must be programmed for not longer than 60 seconds 3 General Control Programming Program Address 002 digit 2 must ...

Page 45: ...r actuated tamper switch installed The Ademco Model AB 12 bell housing see Section 10 4 1 Report Programming Burglar Zone Reports must be programmed for those zones used Low Battery Report Program Address 079 digits 1 2 must be programmed AC Failure Report Program Address 079 digits 5 6 must be programmed Open Report Program Addresses 011 digit 1 and 078 digits 1 2 must be programmed Close Report ...

Page 46: ...lsed or steady must be different from the Fire alarm signal 5 Alarm Output Programming Alarm Output Program Address 009 digit 1 must be programmed as 0 A 10 4 Using the Ademco AB 12 Bell Housing 1 Disconnect the wire jumper from Terminal 4 to the inner housing of the Bell Box 2 Connect wiring between the control and Bell Box as shown above 3 Program Zone 8 as a 24 hour zone Program Address 030 dig...

Page 47: ... over any voice announcement When the delay has ended the numeric message is sent This message includes the account number followed by up to 5 reports If a delay time greater than 10 seconds is required increments of 3 seconds can be added by programming the 3 character 3 second delay at the end of the phone number in Address 017 or 019 For example if you call pager number 123 4567 and it takes 20...

Page 48: ...Page 48 P N 39818D Copyright 2001 Detection Systems Inc DS7080iP 32 Reference Guide Personal Dialing and Pager Format suggested values 4 2 Format suggested values ...

Page 49: ...0iP 32 Reference Guide Copyright 2001 Detection Systems Inc P N 39818D Page 49 11 3 Suggested Values for BFSK and other Pulse Formats For Additional Information see Programming Addresses 054 082 and 117 123 ...

Page 50: ...rammed in the extended digit of the report Addresses 054 082 and 117 123 To activate a report when using the SIA format place a 1 in the first reporting digit To select the type of event for this report place one of the following values in the second digit Data Digit 2 value SIA Report Explanation 1 PA Panic Alarm 2 PR Panic Restore 3 QA Emergency Alarm 4 QR Emergency Restore 5 TA Tamper Alarm 6 T...

Page 51: ...DS7080iP 32 Reference Guide Copyright 2001 Detection Systems Inc P N 39818D Page 51 12 2 Contact ID Format Values Sent For Additional Information see Programming Addresses 054 082 and 117 123 ...

Page 52: ...Page 52 P N 39818D Copyright 2001 Detection Systems Inc DS7080iP 32 Reference Guide 12 3 High Speed 4 9 Format For Additional Information see Programming Addresses 054 082 and 117 123 ...

Page 53: ...DS7080iP 32 Reference Guide Copyright 2001 Detection Systems Inc P N 39818D Page 53 12 3 High Speed 4 9 Format continued ...

Page 54: ...eport 078 Partition 1 Account Codes 013 Partition 1 Alpha 083 Partition 2 Account Codes 014 Partition 2 Alpha 084 Partitioning 002 Phone Answer Rings Armed 012 Phone Answer Rings Disarmed 012 Phone Controls 012 Phone 1 017 Phone 1 Format 015 Phone 2 019 Phone 2 Format 016 Phone 3 021 PIN Length 003 Programmable Output 1 009 Programmable Output 2 009 Programmer s Code 004 Recent Closing Report 081 ...

Page 55: ...mercial mode 3 Keypad yellow wire missing or shorted 1 Correctly set address jumper s for that keypad 2 PIN required before 87 3 Check keypad wiring 87 display Keypad Fault 1 Keypad Yellow Green or Red wire missing from another keypad This will not display if this is the faulted keypad It is intended to show status on other keypads 1 Check keypad wiring Keypad displays DSI Version 2 00 Copyright 1...

Page 56: ...t format must be 0 6 Disconnect house phones at Terminals 28 29 If dial tone is not present at panel anymore the street and house lines may be reversed 7 Call receiver number with handset to see if receiver picks up Automatic Test report not sent 1 Time and Date not set 2 Report not programmed 3 Not programmed to send 1 Set time and date Can be lost due to power loss 2 Check Address 082 3 Check Ad...

Page 57: ... 2 Chime mode not on 1 Chime mode only works for perimeter zones Also if the zone has trouble enabled it will not activate on a trouble condition Check Address 034 037 2 Activate chime mode PIN 7 Keypad displays Ready To Arm and can not arm system Entry Error Please Try Again 1 Zone programmed as a Keyswitch On Off 2 Panel in Residential mode 3 Invalid PIN or does not have authority 4 A zone is pr...

Page 58: ...24 Enclosure 4 5 Entry Delay Timers 13 Entry Exit Delay 10 13 Error Display 1 Error Display Reset 1 Escape Plan 16 Event History Readback 1 22 Event History Readback Control 14 Exit Delay Timers 13 Exit Error Report 14 38 F Fire Key 12 Fire Reset 1 Fire Trouble 1 Fire Zone 10 11 Fire Zone with Verification 10 33 Fire Zone without Verification 33 First Open After Alarm Report 14 Force Arming 1 13 F...

Page 59: ...g 14 39 Point Expansion Module Missing Restoral 14 39 Point Expansion Module Tamper 14 40 Point Expansion Module Tamper Restoral 14 40 Recent Closing 14 38 Remote Program Successful 14 Remote Program Unsuccessful 14 Remote Programming Successful 38 Remote Programming Unsuccessful 38 System Test 14 38 System Test Restoral 14 38 System Trouble 14 38 System Trouble Restoral 14 38 Trouble Restoral 37 ...

Page 60: ...ection Systems Inc 130 Perinton Parkway Fairport New York USA 14450 9199 585 223 4060 888 289 0096 Fax 585 223 9180 Copyright 2001 Detection Systems Inc DS7080iP 32 Reference Guide P N 39818D 11 01 Page 60 ...

Reviews: