9V Battery
P/N: PP-5567 (or equivalent)
Battery retainer
P/N: 102606
Circuit board kit
P/N: 102656-1 (Standard)
Cam assembly kit
P/N: 102655
Magnet locator
P/N: 102607
Switch guard
P/N: 102613
03 Rim cylinder plate
P/N: 102638
#8-32 Truss HD screw
P/N: 102627-15
Cover lock,
nut, and 2 keys
P/N: PP-5572
Cylinder nut
P/N: 100783
Parts breakdown depiction
(Mortise cylinder required)
Locate this component for Step 6
DETEX 101321
INSTALLATION INSTRUCTIONS FOR THE EAX-500 EXIT ALARM
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045
(830)629-2900 / 1-800-729-3839 / Fax (830)620-6711
E-MAIL: detex@detex.com INTERNET: www.detex.com
101321 September 15, 2008
U.S. PATENT NUMBERS:
20050257389
20050231363
20050223764
Magnet Kit
P/N: 102665
Hardware Kit
P/N: 102633
Backplate
P/N: 102603
Mortise cylinder required (standard yale cam)
Detex P/N: 102281-X
CORRECT
"ON" position
(Key can be removed)
position
shown in "OFF"
Key and cams
"OFF" position
(Key cannot be removed)
.050" Hex Wrench
(NOT PROVIDED)
position
stop "ON"
shown in 90°
Key and cams
"ON"
position
(If Key
Stop
installed)
EAX-500 Operations
Key orientation
Figure 1
"OFF"
position
"ON"
position
NOTE: Key Stop will prevent key
removal in "OFF" position
(Key stop included in hardware kit)
Rotate key to this
position before reinstalling
cam assembly
Mortise cam orientation
as shown
Key stop
installed
Ins No: 101321
NOTE: Depending on models ordered, delay times may vary
WRONG
Back View
Front View
Cam orientation
for Key Stop option
KEY STOP POSITIONS
Figure 2:
KEY STOP INSTALLATION
Top surface of Key Stop should
NOT
protrude beyond highest
point on plastic cam
Install key stop
P/N: 102688
SPECIAL NOTES and DEFINITIONS:
1. The door needs to be closed to test the unit.
2. When operating the ON/OFF switch, there is a slight delay.
3. The key is inserted and removed only in the vertical position (home position).
4. Key function: counter clockwise (CCW) = Armed; clockwise (CW) = Disarmed
5. The battery needs to be disconnected to register changes in the slide switches.
a. Status Indicator (This will affect battery life)
b. Disable Auto Rearm
6. The bottom left switch is only used when the outside key control function is used.
7. If re-handing is necessary remove battery and place magnet on left or right side and reconnect the battery.
OPERATIONS:
To arm the system, close the door and turn the key counter clockwise (CCW) to the 8 o'clock position or until you
feel and/or hear a click. The switch on the bottom right side of the board should be engaged by the plastic
actuator and maintained. This is the 'ON' position. The red light should blink twice and the green light will come
on solid for the arming time sequence (default 15 seconds). After the arming time, the green light will turn off and
the unit will beep three times. At this time, the alarm is armed and if the door is opened the alarm will sound and
the red light will turn on.
DISARMING:
To turn off the alarm or disarm the system, turn the key clockwise (CW) to the 2 o'clock position.
The bottom right switch should be released.
TROUBLESHOOTING:
If the unit does not arm, the magnet may need to be re-aligned or shimmed closer to the EAX-500. If the unit fails
to operate, confirm the slide switches are in the default condition (see step 4) and disconnect and reconnect the
battery. If re-handing is necessary remove battery and place magnet on left or right side and reconnect the battery.
LOW BATTERY ALERT:
1. Siren will beep and red LED will blink at approximately 45 second intervals when battery is low
STATUS INDICATOR:
1. Slide the switch to ON and then, install battery.
2. If the unit is armed, the red LED will blink every 3 seconds.
3. If the unit is disarmed, the green LED will blink every 3 seconds.
Disable AUTO REARM:
1. Slide switch to OFF and then, install battery.
2. Unit arms as described above.
3. Once the unit is in full alarm and the door closes, the alarm will shut off after 2 minutes.