background image

DCT414-XE

10.8 V CORDLESS IR THERMOMETER

INSTRUCTION MANUAL

Summary of Contents for DCT414-XE

Page 1: ...DCT414 XE 10 8 V CORDLESS IR THERMOMETER INSTRUCTION MANUAL ...

Page 2: ......

Page 3: ... the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Do not overreach Keep proper footing and balance at all times This enables better control of the power tool in unexpected situations e Dress properly Do not wear loose clothi...

Page 4: ...alternating current As little as 10 lower voltage can cause loss of power and can result in overheating All DEWALT tools are factory tested if this tool does not operate check the power supply Your DEWALT tool is double insulated therefore no earth wire is required Young children and the infirm This appliance is not intended for use by young children or infirm persons without supervision Young chi...

Page 5: ...W WARNING ALWAYS wear approved protective safety equipment complying with the following standards Eye protection AS NZS1337 Eye Protectors for Industrial Applications Hearing protection AS NZS1270 Acoustics Hearing Protection Respiratory protection AS NZS1716 Respiratory Protective Devices WARNING We recommend the use of a residual current device with a residual current rating of 30mA or less CAUT...

Page 6: ...ottom of the housing WARNING Fire hazard Never attempt to open the battery pack for any reason If battery pack case is cracked or damaged do not insert into charger Do not crush drop or damage battery pack Do not use a battery pack or charger that has received a sharp blow been dropped run over or damaged in any way i e pierced with a nail hit with a hammer stepped on Damaged battery packs should ...

Page 7: ...dicated by the red light remaining ON continuously The pack is fully charged and may be used at this time or left in the charger Indicator Light Operation Charge Indicators Some chargers are designed to detect certain problems that can arise with battery packs Problems are indicated by the red light flashing at a fast rate If this occurs re insert battery pack into the charger If the problem persi...

Page 8: ...from charger cavities Always unplug the charger from the power supply when there is no battery pack in the cavity Unplug charger before attempting to clean 6 Do not freeze or immerse charger in water or any other liquid WARNING Shock hazard Don t allow any liquid to get inside charger Electric shock may result CAUTION Never attempt to open the battery pack for any reason If the plastic housing of ...

Page 9: ...it indicated by both the LED and the beeper I Min Max Avg Mode Button Displays either the lowest highest or average temperature J Adjustment Button Used with each mode button to set desired value K EMS Mode Button Set emissivity value L C F Mode Button Used to set temperature units of measure Celsius or Fahrenheit M LED Indicator Active in Alarm 1 and Alarm 3 modes Blue serves as alarm to show tha...

Page 10: ...ded users If the hook is not desired at all it can be removed from the tool To move belt hook remove the screw P that holds the belt hook in place then reassemble on the opposite side OPERATION WARNING To reduce the risk of serious personal injury turn tool off and disconnect battery pack before making any adjustments or removing installing attachments or accessories FIG 3 E F A M G H I J K L Hold...

Page 11: ... up or down arrow buttons to choose the emissivity Please refer to the chart in order to choose the correct emissivity Remember emissivity adjusts in 0 01 increments NOMINAL EMISSIVITY MANUAL MATERIAL VALUE MATERIAL VALUE Default 0 95 Lead 0 50 Aluminum 0 30 Oil 0 94 Asbestos 0 95 Paint 0 93 Asphalt 0 95 Plastic 0 95 Brass 0 50 Rubber 0 95 Ceramic 0 95 Sand 0 90 Concrete 0 95 Steel 0 80 Copper 0 6...

Page 12: ... the IR Thermometer trigger when not taking temperature readings MAINTENANCE WARNING To reduce the risk of serious personal injury turn tool off and disconnect battery pack before making any adjustments or removing installing attachments or accessories Lubrication Your power tool requires no additional lubrication Cleaning WARNING Blow dirt and dust out of all air vents with clean dry air at least...

Page 13: ...te Legislation Australia only In addition to the warranty DEWALT tools are covered by our FREE ONE YEAR SERVICE CONTRACT DEWALT will also maintain the tool for free at any time during the first year of purchase This includes labour parts and lubrication required to restore the product to sound mechanical and or electrical condition Normal wear parts are not covered in this service Carbon brushes w...

Page 14: ......

Page 15: ......

Page 16: ...180 18 2 0 X X X X X X X X X X X X X X X X 60 X X 60 DW9096 18 2 4 X X X X 60 X 60 20 X 60 X 60 60 X X X 60 X 60 60 DE9095 XJ 18 2 0 X X X X 60 X 60 20 X 60 X 60 60 X X X 60 X 60 60 DC9091 14 4 2 4 60 60 60 60 60 15 60 15 60 60 60 60 60 X X X 60 X 60 60 DC9144 14 4 2 0 X X X X X X X X X X X X X X X X 60 X X 60 DE9094 14 4 1 3 45 45 45 30 30 15 30 12 60 30 60 30 30 X X X 30 X 30 30 DE9091 XJ 14 4 2...