background image

 

 

NDS3542D Multi-input Modulator 

User’s Manual 

 

 

 

 

 

Web-NMS Version: 1.08 Build 100 Nov 4 2015 

Software: 1.30 

Hardware:1.04 

 

 

 

Chengdu Dexin Digital Technology Co., Ltd.

 

 

WWW.KONTURM.RU

Summary of Contents for Fiber Labs NDS3542D

Page 1: ...NDS3542D Multi input Modulator User s Manual Web NMS Version 1 08 Build 100 Nov 4 2015 Software 1 30 Hardware 1 04 Chengdu Dexin Digital Technology Co Ltd W W W K O N T U R M R U...

Page 2: ...Chapter 2 Installation Guide 5 2 1 Acquisition Check 5 2 2 Installation Preparation 5 2 3 Wire s Connection 7 2 4 Signal Cable Connection 8 Chapter 3 Operation 9 3 1 LCD Menu Tree 10 3 2 General Setti...

Page 3: ...and save it in ts files in the USB Keys or Hard Disks and then the ts files can be playback through the USB port The four CAMs CIs accompanied and BISS modules can descramble the programs input from...

Page 4: ...ner Section DVB S2 Demodulation Mode QPSK 8PSK Maximum PID Remapping 128per input channel PID remapping automatically or manually Accurate PCR adjusting Multiplexing Function Generate PSI SI table aut...

Page 5: ...300mm 44 5mm W D H Weight 3 7kg Temperature 0 45 Operation 20 80 Storage Power AC 100V 1050 60Hz AC 220V 10 50 60HZ General Consumption 25W 1 5 Appearance and description Front Panel Illustration 1 L...

Page 6: ...d slots and 2 RF signal input and loop through 2 Module 2 with 2 CAMs Smart card slots and 2 RF signal input and loop through 3 2 separate ASI input Interface 4 2 separate groups of ASI output 5 RF ou...

Page 7: ...ation Preparation When users install device please follow the below steps The details of installation will be described at the rest part of this chapter Users can also refer rear panel chart during th...

Page 8: ...aling door gaps and dual level glasses for window Wall It can be covered with wallpaper or brightness less paint Fire Protection Fire alarm system and extinguisher Power Requiring device power air con...

Page 9: ...ce s grounding rod to frame s grounding pole with copper wire 2 3 Wire s Connection The grounding wire conductive screw is located at the right end of rear panel and the power switch fuse power supply...

Page 10: ...l connections include the connection of input signal cable and the connection of output signal cable The details are as follows NDS3542D Modulator Cable Illustration NMS Cable illustration CAT5 RF Inp...

Page 11: ...scription MENU Cancel current entered value resume previous setting Return to previous menu ENTER Activate the parameters which need modifications or confirm the change after modification LEFT RIGHT C...

Page 12: ...NDS3542D Multi input Modulator User s Manual 3 1 LCD Menu Tree 10 W W W K O N T U R M R U...

Page 13: ...ing Channel D Same submenus with Channel A Same submenus with Channel A Main Menu CI Card CI Card Card A CI Card Card D Card A Max Birate Input TS Mode Card Error Check Parse Program Descramble Progra...

Page 14: ...NDS3542D Multi input Modulator User s Manual 12 W W W K O N T U R M R U...

Page 15: ...e Main menu Status Input Sets CI Card BISS descrambling TS config Modulator IP Stream USB Device Network System User could do all the settings according to the 8 directions displayed on the LCD User c...

Page 16: ...e setting principle for the 4 tuner is the same as Tuner DVB S2 1 Tuner parameters Users can enter this menu to configure the each parameter according to your signal source to receive TS Make sure the...

Page 17: ...figure the 4 cards respectively TS Locked Bitrate 4 040 Mbps Searching Program Get 4 Programs For reading the number of programs from corresponding channel Mux Program 0 4 1 DTV X Mux Program 0 4 1 DT...

Page 18: ...Status Descramble Error Max Bit rate CI Max Bitrate options range from 48 108Mbps Move the triangle to select a value as principle Actual Input Bitrate Max Bitrate CI Max decrypting capacity Max Bitr...

Page 19: ...y to be descrambled will depend on the CAM CI performance you apply to 1 CETV 1 2 CCTV 4A X Rom Version Card Status Descramble Error Users can read the other info about the CI card in the following me...

Page 20: ...m Input TS Mode Skip BISS Tuner 1 Word Mode Burned Key Descrambler Key SK Users need to input keys to descramble programs as per the BISS scrambling side which usually is DVB S S2 modulator The descra...

Page 21: ...3 2 5 TS Config Enter TS Config to configure the TS output parameters TS Config Channel A Channel B Channel C Channel D User can enter Channel A Channel B Channel C Channel D to set the corresponding...

Page 22: ...ormation Table is a very important table for describing the network and TS Users can set NIT parameters under this menu TS ID 00001 ON ID 00001 Tuner 1 Tuner 2 Tuner 3 Tuner 4 ASI 1 ASI 2 USB To outpu...

Page 23: ...ssible options provided for selecting bandwidth 6M 7M and 8M When the display shows them user just need swift LEFT and RIGHT key to choose and repressing ENTER to confirm Standard J 83A J 83B J 83C Co...

Page 24: ...1db step After entering this setting submenu user can shift UP DOWN LEFT RIGHT key to set the output level and press ENTER to confirm RF On This interface is to decide whether to enable the RF carrier...

Page 25: ...choose to update CPU or FPGA at this menu USB port can be used to record encoded TS and playback TS files ts Choose to update CPU or FPGA USB Device 23 USB update Operation User can choose the operat...

Page 26: ...For example when the file size is set as 1000M and the ts is recorded up to 1000M it automatically stops recording TS Segment file For example when the file size is set as 1000M and the ts is recorde...

Page 27: ...Gateway MAC Address Web NMS Port Reset Password NMS IP The IP address for connecting the device to PC 3 2 9 System Users can set the system parameters in this menu Enter System submenus to separately...

Page 28: ...configuration No Reset All Sets Choose yes to restore the device into factory s default configuration Yes No LCD Time out Press DOWN UP key to select a time out for the LCD lighting duration 5 120 se...

Page 29: ...ith net cable and use ping command to confirm they are on the same network segment I G the PC IP address is 192 168 99 252 we then change the device IP to 192 168 99 xxx xxx can be 1 to 254 except 252...

Page 30: ...S is normal which otherwise turns to red User can click any item here to enter the corresponding interface to check information or set the parameters Figure 2 Parameters Input 1 4 From the menu on lef...

Page 31: ...as below where to add the program descriptor in NIT Table Figure 5 After setting all the data users need to click on Save to save the setting Parameters Mux From the menu on left side of the webpage c...

Page 32: ...ut program information Select one input program first and click this button to transfer the selected program to the right box to output Similarly user can cancel the multiplexed programs from the righ...

Page 33: ...rds to descramble programs from Tuner input Users can click and enter CI Card to configure the 4 cards respectively Figure 8 Card Selection Area Figure 8 CI Max Bit rate CI Max Bitrate options range f...

Page 34: ...nfiguring CI card parameters click button to apply the input data and then click button to parse programs from the channel selected in Input TS Mode The searched out programs will be listed in the Des...

Page 35: ...where users can configure 4 BISS and descramble the input channels Figure 10 BISS Selection Area Figure 10 Input TS Mode One BISS can be applied to descramble one corresponding Tuner input signal sou...

Page 36: ...utton to parse programs from the channel selected in Input TS Mode The searched out programs will be listed in the Descramble box below Figure 11 Program list from the channel selected in Input TS Mod...

Page 37: ...odule without changing anything This is the main purpose of this function Click this button to generate more rows to add PIDs Figure 13 Parameters Modulator From the menu on left side of the webpage c...

Page 38: ...t USB device and signal source and activate modulating to operate TS recording NOTE It is necessary to connect USB device when operate TS playing Operation Mode selection Area Null Play TS and Record...

Page 39: ...recorded A single file can be maximum 4000M in size There are 3 File record modes provided Single file For example when the file size is set as 1000M and the ts is recorded up to 1000M it automatical...

Page 40: ...device information and configurations User can t operate the keyboard LCD while only the device IP address can be noted in the LCD window IP Address 192 168 000 136 System Password From the menu on l...

Page 41: ...the webpage clicking Backup Load it will display the screen as Figure 21 where to backup or load your configurations Figure 21 System Firmware From the menu on left side of the webpage clicking Firmwa...

Page 42: ...NDS3542D Multi input Modulator User s Manual Figure 22 40 W W W K O N T U R M R U...

Page 43: ...king sure good ventilation for the heat sink on the rear panel and other heat sink bores if necessary Checking the input AC voltage within the power supply working range and the connection is correct...

Page 44: ...S3542D Multi input Modulator User s Manual 42 Chapter 6 Packing List NDS3542D Multi input Modulator 1pcs User s Manual 1pcs RF Loopout Cables 4pcs ASI Cable 1pcs Power Cord 1pcs W W W K O N T U R M R...