background image

DL9206

AUTORANGING

MULTIMETER 

operating manual

EN

61010-1

CAT

 

III

600V

Summary of Contents for DL9206

Page 1: ...DL9206 AUTORANGING MULTIMETER operating manual EN 61010 1 CAT III 600V ...

Page 2: ...tential danger refer to the instruction manual to avoid personal injury or damage to the meter Caution Dangerous voltage Danger of electrical shock Continuous double or reinforced insulation complies with IEC536 class II Symbol of conformity confirms conformity with relevant EU directives The meter complies with EMC directives 89 336 EEC Specifically stand ards EN 50081 1 and EN 50082 1 as well as t...

Page 3: ...nd the connectors If the case is damaged do not use the meter Check the test leads for damaged insulation or exposed metal Check the leads for continuity Replace damaged leads with identical model or specification before using the meter Where applicable use GS38 approved leads not supplied these are available from Di Log When using test leads keep fingers behind the finger guards Do not apply more th...

Page 4: ...range step by step until a satisfactory reading is obtained Do not use or store the meter in an environment of high temperature humidity fumes vapour gaseous inflammable and strong magnetic field The perform ance and safety of the use may be compromised in such circumstances Disconnect circuit power and discharge all high voltage capacitors before testing resistance continuity diodes capacitance or ...

Page 5: ... meter may give false readings Turn the meter power off when not in use Remove the battery if the meter is in use for a long period Constantly check the battery as it may have leaked A leaking battery will damage the meter The meter may only be opened by a qualified service technician for calibration and repair ...

Page 6: ...urrent or Voltage DC Direct Current or Voltage Never apply voltage or current to the meter that exceeds the specified maximum Function Maximum V DC or V AC 1000V DC 750V AC A DC AC 10A DC AC 30 seconds max every 15 minutes Frequency Resistance 250V DC AC Capacitance Duty Cycle Diode test Continuity Temperature 250V DC AC ...

Page 7: ...unction rotary switch 3 10A positive input terminal for 10A DC or AC measurements 4 COM negative input terminal 5 Positive input terminal 6 HOLD pushbutton 7 Max Min pushbutton 8 Range Diode pushbutton 9 Hz Duty pushbutton Controls and Inputs 1 2 3 8 9 5 6 7 4 ...

Page 8: ... voltage drops below the operating level Measurement rate 2 times per second nominal Auto power off Meter automatically shuts down after approx 15 minutes of inactivity Operating environment 0 C to 50 C 32 F to 122 F at 70 relative humidity Storage temperature 20 C to 60 C 4 F to 140 F at 80 relative humidity For inside use max height 2000m Pollution degree 2 Power One 9V battery NEDA 1604 IEC 6F2...

Page 9: ... 1000V 1V 1 5 of rdg 2 dgts Input Impedance 7 8MΩ Maximum Input 1000V dc or 750V ac rms AC Current Auto ranging for uA and mA Range Resolution Accuracy 10A 1mA 3 0 of rdg 7 dgts Overload Protection 10A 250V Fuse Frequency Range 50 to 60 Hz Maximum Input 10A dc or ac rms on 10A AC range AC Voltage Range Resolution Accuracy 6 000V 1mV 1 2 of rdg 3 dgts 60 00V 10mV 1 5 of rdg 3 dgts 600 0V 100mV 750V...

Page 10: ...racy 40 00nF 10pF 5 0 of rdg 7 dgts 400 0nF 0 1nF 4 000uF 1nF 3 0 of rdg 5 dgts 40 00uF 10nF 400 0uF 0 1uF 5 0 of rdg 5 dgts 4000uF 1uF 5 0 of rdg 5 dgts Input Protection 250V dc or 250V ac rms Frequency Auto ranging Range Resolution Accuracy 6 999Hz 0 001Hz 69 99Hz 0 01Hz 1 5 of rdg 5 dgts 699 9Hz 0 1Hz 6 999kHz 1Hz 69 99kHz 10Hz 1 2 of rdg 3 dgts 699 9kHz 100Hz 2 999MHz 1kHz 1 5 of rdg 4 dgts Se...

Page 11: ...erature Range Resolution Accuracy 20 C 760 C 1 C 3 of rdg 4 F 1400 F 1 F 5 C 9 F Sensor Type K Thermocouple Overload protection 250V dc or ac rms Audible continuity Audible threshold Less than 30Ω Test current 0 3mA Overload protection 250V dc or ac rms Diode Test Range Resolution Accuracy 0 3mAtypical 1mV 10 ofrdg 5dgts Open circuit voltage 1 5V dc typical Overload protection 250V dc or ac rms ...

Page 12: ...lly shuts the meter OFF if 15 minutes elapse between uses 2 If OL appears in the display during a measurement the value exceeds the range you have selected Change to a higher range Note On some low AC and DC voltage ranges with the test leads not connected to a device the display may show a random changing reading This is normal and is caused by the high input sensitivity The reading will stabiliz...

Page 13: ...turn off 2 Press the RANGE button to step through the available ranges until you select the range you want 3 Press and hold the RANGE button for 2 seconds to exit the Manual Ranging mode and return to AutoRanging If backlight is turn on please press BACKLIGHT button it will turn off 4 To select Diode continuity Data Hold Button The Hold function allows the meter to freeze a measurement for later r...

Page 14: ...Operation Hz duty 1 Switch to Hz Duty range 2 Press the Hz Duty button to show the reading in the display and the Hz Duty indicator will appear on the display ...

Page 15: ... black test lead banana plug into the negative COM terminal and the red test lead banana plug into the positive V terminal 3 Connect the test probe tips to the circuit under test Be sure to observe the correct polarity red lead to positive black lead to negative 4 Read the voltage in the display The display will indicate the proper decimal point and value If the polarity is reversed the display wi...

Page 16: ...INSIDE THE OUTLET BEFORE ASSUMING THAT NO VOLTAGE IS PRESENT Caution DO NOT MEASURE AC VOLTAGES IF A MOTOR ON THE CIRCUIT IS BEING SWITCHED ON OR OFF LARGE VOLTAGE SURGES MAY OCCUR THAT CAN DAMAGE THE METER 1 Set the function switch to the V AC position 2 Insert the black test lead banana plug into the negative COM terminal and the red test lead banana plug into the positive V terminal 3 Connect t...

Page 17: ...the function switch to the DC 10A position and insert the red test lead banana plug into the 10A terminal 3 Remove power from the circuit under test then open up the circuit at the point where you wish to measure current 4 Connect the black test probe tip to the negative side of the circuit Connect the red test probe tip to the positive side of the circuit 5 Apply power to the circuit 6 Read the c...

Page 18: ...ve COM terminal 2 For AC current measurements set the function switch to the AC 10A position and insert the red test lead banana plug into the 10A terminal 3 Remove power from the circuit under test then open up the circuit at the point where you wish to measure current 4 Connect the black test probe tip to the negative side of the circuit And connect the red test probe tip to the positive side of...

Page 19: ...Ω position 2 Insert the black test lead banana plug into the negative COM terminal and the red test lead banana plug into the positive Ω terminal 3 Connect the test probe tips across the circuit or part under test It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 4 Read the resistance in the display The display will i...

Page 20: ... black lead banana plug into the negative terminal COM and the red test lead banana plug into the positive terminal Ω 3 Press the button until the symbol appears in the display 4 Connect the test probe tips to the circuit or wire you wish to check 5 If the resistance is less than approximately 30Ω the audible signal will sound The display will also show the actual resistance ...

Page 21: ...inal Ω 4 Connect the test probe tips to the diode or semiconductor junction you wish to test Note the meter reading 5 Reverse the probe polarity by switching probe position Note this reading 6 The diode or junction can be evaluated as follows A If one reading shows a value and the other reading shows OL the diode is good B If both readings show OL the device is open C If both readings are very sma...

Page 22: ...test lead banana plug into the negative terminal COM and the red test lead banana plug into the positive terminal F 3 Connect the test probe tips to the circuit under test 4 Read the frequency in the display The digital reading will indicate the proper decimal point symbols Hz kHz and value ...

Page 23: ...ERIES AND UNPLUG THE LINE CORDS 1 Set the function switch to the CAP position nF and a small value will appear in the display 2 Insert the black test lead banana plug into the negative terminal COM and the red test lead banana plug into the positive terminal CAP 3 Connect the test leads to the capacitor to be tested The display will indicate the proper decimal point value and symbol ...

Page 24: ...le probe black test lead banana plug into the negative COM terminal and the red test lead banana plug into the positive Temp terminal 3 Connect the Temperature Probe head to the part whose temperature you wish to measure Keep the probe connected to the part under test until the reading stabilizes about 30 seconds 4 Read the temperature in the display The digital reading will indicate the proper de...

Page 25: ...ttery cover by loosening the screw using a Phillips head screwdriver 4 Insert the battery into battery holder observing the correct polarity 5 Put the battery cover back in place Secure with the two screws 6 Follow instructions for installing battery See the Battery Installation section of this manual Warning TO AVOID ELECTRIC SHOCK DO NOT OPERATE THE METER UNTIL THE BATTERY COVER IS IN PLACE AND ...

Page 26: ... door using a Phillips head screwdriver 3 Remove the old fuse from its holder by gently pulling it out 4 Install the new fuse into the holder 5 Always use a fuse of the proper size and value 0 5A 250V fast blow for the 400mA range 10A 250V fast blow for the 10A range 6 Put the fuse cover back in place Insert the screw and tighten it securely Warning TO AVOID ELECTRIC SHOCK DO NOT OPERATE YOUR METE...

Page 27: ...Notes ...

Page 28: ...ed the instrument has not been tampered with and returned to us unopened Damage due to dropping abuse or misuse is not covered by the warranty Outside the warranty period we offer a full repair and re calibration service Maintenance WARNING Do not attempt to repair or service you meter unless you are qualified to do so and have the relevant calibration performance test and service information To av...

Reviews: