background image

1

PL7900-T42/PL7901-T42

Installation Guide

WARNINGS

• Do not push on the PL’s screen too strongly, with either your finger or with a hard object. Exces-

sive pressure can scratch, crack or damage the screen. Do not use a pointed object, such as a

mechanical pencil or screwdriver, to press any of the touch panel’s switches, since they can

damage the display.

• If the screen becomes dirty or smudged, moisten a soft cloth with diluted neutral detergent,

wring the cloth well, and wipe the display. Do not use thinner or organic solvents.

• Avoid storing and operating the PL in direct sunlight, high temperatures and humidity, and in

areas where excessive dust and vibration will occur.

• Avoid using the PL in areas where sudden, extreme changes in temperature can occur. This

may cause condensation to form inside the unit, possibly leading to an accident.

• To prevent the PL from overheating, be sure its air circulation vents are clear and clean, and

keep the unit’s operation area well-ventilated.

• Avoid operating or storing the PL near chemicals, or where chemicals can come into contact with the unit.

• The Digital Electronics Corporation cannot be held responsible or provide any compensation for

damage(s) caused by the loss of data stored in the PL™s hard disk drive (HDD). It is therefore

strongly suggested that all important data and software be backed up regularly to an external

data backup device.

• After turning OFF the PL's power, wait until the internal HDD stops spinning before turning on the

power again (approx. 5 seconds).

• To prevent an electric shock, be sure to connect the power cord to the PL before connecting it to

the main power supply.

• A fire or electrical shock may occur if voltages used with the PL are beyond the specified range.

Be sure to use only the specified voltage.

• Before opening the PL’s protective cover, be sure to turn the unit’s power OFF.  This is because

the PL’s internal parts carry high voltages.

• To avoid fires or electrical hazards, do not modify the PL in any way.

• Do not create touch panel switches that are used to either control or to ensure the safety of

equipment and personnel. Mechanical switches, such as an emergency stop switch, a deadman

(two-handed) start switch, etc., must be installed and operated via a separate control system.

• Do not create touch panel switches which could possibly endanger the safety of humans or

equipment. This is due to the possibility of a malfunction in the GP or its cable(s) causing the

output of a signal that could result in a major accident. All of a system's  major, safety-related

switches should be designed to be operated separately from the GP.

• After the PL’s backlight burns out, unlike the PL’s “Standby Mode”, the touch panel is still active.

If the operator fails to notice that the backlight is burned out and touches the panel, a potentially

dangerous machine miss-operation can occur.

If your PL's backlight suddenly turns OFF, use the following steps to determine if the backlight is

actually burned out.

1) If your PL is not set to "Standby Mode" and the screen has gone blank, your backlight is burned out.

2) Or, if your PL is set to Standby Mode, but touching the screen does not cause the display to

  reappear, your backlight is burned out.

• If metal particles, water or other types of liquids contact any of the PL’s internal parts, immedi-

ately turn the unit’s power OFF, unplug the power cord, and contact either your PL distributor or

the Digital Electronics Corporation.

• Before either plugging in or unplugging a board or interface connector, be sure to turn the PL’s power OFF.

• To prevent a possible explosion, do not install the PL in areas containing flammable gases.

• The PL is not appropriate for use with aircraft control devices, aerospace equipment, central

trunk data transmission (communication) devices, nuclear power control devices, or medical life

support equipment, due to these devices’ inherent requirements of extremely high levels of

safety and reliability.

• When using the PL with transportation vehicles (trains, cars and ships), disaster and crime

prevention devices, various types of safety equipment, non-life support related medical devices,

etc. redundant and/or fail-safe system designs should be used to ensure the proper degree of

reliability and safety.

To Prevent Accidents

Summary of Contents for PL7900-T42

Page 1: ...t are used to either control or to ensure the safety of equipment and personnel Mechanical switches such as an emergency stop switch a deadman two handed start switch etc must be installed and operated via a separate control system Do not create touch panel switches which could possibly endanger the safety of humans or equipment This is due to the possibility of a malfunction in the GP or its cabl...

Page 2: ... same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Be sure the unit the PL is built into uses a UL1950 compatible equipment structure The PL790 T4 units are CE marked EMC compliant products Complies with the following Standards Safety EN60950 EMI EN50081 2 EN55011 group1 Class A EMS EN50082 2 EN61000 4 2 EN61000 4 3 EN610...

Page 3: ...er software follow the steps given below 1 This software in the form of a self extracting file is located in this CD ROM in the folder titled reader Use the Explorer software to find the file reader ENG ar405eng exe and double click on the file icon to begin the Reader installation 2 After Installation begins follow the instructions given on the Installation screens Viewing the PDF manual To view ...

Page 4: ...ot D E F G H C A B M J K L P N H T U S Q R V W X PL 7900T 4Slot PL 7900T 4Slot I O A Display Area B Touch Panel C Power Lamp LED D Front Maintenance Cover E IrDA F Keyboard Connector G Hardware Reset Switch H FDD Slot only for PL 7900T I Brightness Adjustment Slide J RS 232C Connector COM1 K RS 232C Connector COM2 L RS 232C Connector COM3 M Printer Connector LPT1 N RAS Connector O Power Terminals ...

Page 5: ...eneral Dimensions Side View Top View Front View Side View Top View Front View 359 14 13 374 14 72 325 12 80 180 7 09 13 0 51 310 12 20 359 14 13 374 14 72 325 12 80 134 5 28 310 12 20 13 0 51 Unit mm in excluding projections Unit mm in excluding projections ...

Page 6: ...RH to 85 RH no condensation Noise Immunity 4kV IEC 61000 4 2 Storage Temperature Ambient Humidity Air Purity Level Atmosphere Vibration Resistance Noise Endurance via noise simulator Electrostatic Discharge Immunity 1kV IEC 61000 4 4 PL 7900T PL 7901T Input Voltage Rated Voltage Frequency Allowable Voltage Drop Power Consumption less than 150VA less than 100VA AC 100V to AC 240V AC 85V to AC 265V ...

Page 7: ...are removed from the panel the original level of the protection cannot be guaranteed To main tain the original protection level you need to replace the installation gasket regularly PL 7900T PL 7901T Grounding Rating 1 Cooling Method Weight Less than 10 5 kg 23 1 lb with HDD and FDD installed Less than 9 5 kg 20 9 lb with HDD and FDD installed External Dimensions W374 mm 14 72 in x H325 mm 12 80 i...

Page 8: ... SPP ECP Mode Signal Name EPP Mode Signal Name Direction Electrical Specif 1 STRB WRITE In Output O D 14 AUTOFD DSTRB In Output O D 2 DATA0 DATA0 In Output O D 15 ERROR ERROR Input TTL 3 DATA1 DATA1 In Output O D 16 INIT INIT In Output O D 4 DATA2 DATA2 In Output O D 17 SLCTIN ADSTRB In Output O D 5 DATA3 DATA3 In Output O D 18 GND GND 6 DATA4 DATA4 In Output O D 19 GND GND 7 DATA5 DATA5 In Output...

Page 9: ...V 16 NC 4 NC 17 NC 5 RESET INPUT 18 NC 6 DIN 0 19 NC 7 DOUT 20 NC 8 DOUT 21 LAMP OUT 9 ALARM OUT 22 LAMP OUT 10 ALARM OUT 23 NC 11 RESET INPUT 24 DIN1 12 DIN 0 25 NC 13 DIN 1 The GND terminal is the signal ground Be sure to connect the GND terminal to other unit s SG signal ground 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Mini DIN 6 pin Female 6 4 2 1 3 5 Mouse Interface Pi...

Page 10: ...sed Photo isolation Interface Circuit Connection Example 5V R Input Port PC357 3 3kΩ 1 4W D sub 25 pin Connector DC12V to DC24V External Power Reset Input pin 5 DIN0 pin 6 DIN1 pin 13 12 to 24V Reset Input pin 11 DIN0 pin 12 DIN1 pin 24 Cable DOUT pin 8 Alarm Output pin 10 Lamp Output pin 22 DOUT pin 7 Alarm Output pin 9 Lamp Output pin 21 Interface Circuit Connection Example 5V R Cable D sub 25 p...

Page 11: ...net or panel check that the moisture resistant gasket is attached to the unit Create a Panel Cut Create a panel cut for the PL unit using the dimensions given here Two additional items the moisture resistant gasket and the mounting brackets are also required when installing the PL To obtain the maximum degree of moisture resistance be sure to install the PL on a smooth flat surface The panel itsel...

Page 12: ...ole Mounting bracket Attachment hole Top and Bottom Faces Left and Right sides 123456789012345678901234567890 123456789012345678901234567890 123456789012345678901234567890 123456789012345678901234567890 123456789012345678901234567890 123456789012345678901234567890 123456789012345678901234567890 123456789012345678901234567890 123456789012345678901234567890 123456789012345678901234567890 12345678901...

Page 13: ...erminal s transparent plastic cover POWER Screws Transparent Cover I ON o OFF To prevent electric shocks be sure to turn the PL s power supply OFF before connecting the power cord To avoid the dangers of fire electric hazards and equipment damage be sure to use only the specified power supply voltage when operat ing the PL Use the following steps when connecting the power cord to the PL s power te...

Page 14: ...ned only for AC100 115V use Be sure to use a different cable when using other than AC100 115V power Black White Green Yellow Transparent Cover Attachment Screws 3 Reattach the terminal strip s transparent cover with the attatchment screws Crimp Terminal Types V1 25 3 by J S T or equivalent JIS standard part number RAV1 25 3 Crimp terminals must be the same as shown below L N FG L N FG φ φ φ φ φ 3 ...

Page 15: ...together To prevent damage from lightning connect a lightning surge absorber Constant voltage transformer Twisted pair cable PL FG Insulating transformer Twisted pair cable PL FG Main power source PL power source T1 T2 I O power source PL I O device Main circuit power source Power device AC 200V Ground the lightning surge ab sorber E1 and the PL E2 sepa rately Select a lightning surge absorber whi...

Page 16: ...ated ground is not pos sible use a shared ground as shown in figure b c Shared ground not allowed a Dedicated Ground b Shared Ground allowed I O signal lines must be wired separately from the power circuit cable If the power circuit cable needs to be wired together with the input output I O sig nal lines for any reason use shielded cables and ground one end of the shield to the PL s FG terminal To...

Reviews: