background image

Read the instructions published in this manual carefully before the first use of the sensor.

Keep the manual in a safe place. The manufacturer reserves the right to make changes without prior notice.

Capacitive level meters CLM – 36

Capacitive level meters CLM – 36

INSTRUCTIONS MANUAL

   

  

Summary of Contents for CLM-36 T

Page 1: ...manual carefully before the first use of the sensor Keep the manual in a safe place The manufacturer reserves the right to make changes without prior notice Capacitive level meters CLM 36 Capacitive...

Page 2: ......

Page 3: ...lectrical connection 12 9 Preparing of level meter for measuring 14 10 Settings 15 11 Order code 17 12 Correct specification examples 17 13 Accessories 17 14 Safety protections compatibility and explo...

Page 4: ...ssure vapours dust 2 Basic description To ensure maximum safety of control processes we have defined the following safety instructions and information Each instruction is labelled with the appropriate...

Page 5: ...uncoated rod electrode and reference tube for accurate level meas urement of clean non conductive liquids oils diesel petrol Electrode length from 0 2 m to 3 m CLM 36_ 22 With fully FEP coated rod el...

Page 6: ...6 4 Dimensional drawing CLM 36_ 30 CLM 36_ 10 11 12 CLM 36_ 20 22 type threads M36x2 G1 for materials with a low permittivity r 10 the minimum electrode length is E500 thread High temperature variant...

Page 7: ...6_ 31 Rope electrode Wall of container KV 31 PR 31 Spring Anchor with spherical joint thread Housing with Tri clamp coupling Anchor welding cylinder KV 31 or Dust tight bushing PR 31 see accessories t...

Page 8: ...during measuring of electrically non conductive material is non linear Linearity is done by reference tube CLM 36_ 20 22 Inthetankwithstraightwall forexamplevertical cylinder and with the sensor plac...

Page 9: ...s vessels by level meter without reference tube is necessary to connect grounding screw at housing with auxiliary electrode which is fixed by the appropriate method to the outer casing of vessels or a...

Page 10: ...to be dipped min 20 mm below the lowest measured level h The distance from the bottom min 100 mm a The distance from the wall at least E 20 as far as possible from the walls to the middle between the...

Page 11: ...f the press spring approx 200 mm c the distance from the centre line of the silo has to be as minimal as possible steel anchor welding cylinder mat 11375 or dust tight bushing to be welded into the co...

Page 12: ...screwdriver 2 Use a flat screwdriver to remove the inner part of the connector screwdriver into the gap marked by arrow 3 Unscrew the cable gland and put the cable inside 4 Connect the cable wires to...

Page 13: ...tic charge on the non conductive parts of the sensor it is necessary to ground all sensors intended for use in environments with an explosion hazard type CLM 36Xi XiT This can be performed by groundin...

Page 14: ...1 The trimmers are without backstops approx 15 turns ADJUSTMENT ELEMENTS OF LEVEL METER Fig 10 The top view on the internal electronic module with current output variant I DIP switches for range sele...

Page 15: ...tion 7 Then set the current of CLM by trimmer 20 mA onto 20 mA or to the calculated value of I out see above 8 To reach a maximum accuracy is useful to check the setting of 4 mA again compensation of...

Page 16: ...commended ranges depending on the medium and the type of level meter Medium Plastic granulates r approximately 2 Type electrode length 1 m 2 m 5 m 10 m 20 m 10 30 31 1 2 2 3 4 Medium Flour sand grains...

Page 17: ...m OUTPUT TYPE I current 4 20 mA U voltage 0 10 V LENGTH OF ELECTRODE E electrode length in mm CABLE K cable length in m CLM 36 N 10 G I E1000 K 5 Example of coding 1 Range No 1 70 pF is very sensitive...

Page 18: ...r a surcharge see catalogue sheet of accessories ConnectorwithprotectionclassIP67 GAN DADE 7A with 5 m cable current output ConnectorwithprotectionclassIP67 GAN DAAE 7A with 5 m cable voltage output S...

Page 19: ...European directives for safety and electromagnetic compatibility Special conditions for safe use of variants CLM 36Xi If the apparatus is used as device of Group II and with using of an approved powe...

Page 20: ...er has to be carried out in accordance with this instruction manual the provisions of regulations in force regarding the installation of electrical equipment have to be adhered to The level meter must...

Page 21: ...cate must be presented to exercise a claim In the case of a rightful complaint we will replace the product or its defective part In both cases the warranty period is extended by the period of repair P...

Page 22: ...Tescomy 249 760 01 Zl n Czech Republic www dinel cz Dinel s r o U Tescomy 249 760 01 Zl n Czech Republic www dinel cz t tek pro varianty CLM 36N_ _ _ _ I IP65 IP67 U 0 10 V out U 16 36 V U 3 2 Uout U...

Page 23: ..._ _ _ FTZ 02 ATEX 0235X U 30V I 132mA P 0 99W C 370nF L 0 9mH t 20 60 C zone 0 t 40 75 C a a i i i i i CLM 36Xi __ __ I E_____ No ______ IP65 IP67 1026 II 1G B T5 Ga Ex ia II FTZ 02 ATEX 0235X U 30V...

Page 24: ...standard Optional Connector GAN DADE 7A DAEE 7A IP67 Housing IP65 Connec tor IP67 Maximal load serial resistance for current output U 24 V Rmax 750 Minimal load resistance for voltage output Rmin 1 k...

Page 25: ...th a spark secure power supply unit electrode part zone 0 and 20 head zone 1 and 21 CLM 36XiT 11 12 22 32 Intrinsically safe high temperature explosion proof performance for use in hazardous areas exp...

Page 26: ...C 40 C 75 C 40 C 75 C CLM 36Xi 32 40 C 105 C 40 C 75 C 40 C 75 C CLM 36NT 10 20 40 C 300 C 40 C 200 C 40 C 85 C CLM 36NT 11 12 22 40 C 200 C 40 C 200 C 40 C 85 C CLM 36NT 30 40 C 250 C 40 C 130 C 40 C...

Page 27: ...6Xi 32 1 MPa 0 5 MPa CLM 36NT 10 20 7 MPa 5 MPa 3 MPa 2 MPa 1 MPa CLM 36NT 11 12 22 6 MPa 4 MPa 2 MPa 1 5 MPa 0 3 MPa CLM 36NT 30 7 MPa 5 MPa 3 MPa CLM 36NT 31 CLM 36NT 32 1 MPa 0 5 MPa 0 1 MPa CLM 36...

Page 28: ...roforme 4 8 Ice 3 1 Liquefied air 1 5 Material r Liquefied CO2 1 6 Liquefied chlorine 2 Liquefied propane 1 6 1 9 Marble 9 3 11 6 Methanol 33 Mica 5 8 Mikanite 4 5 6 Milk powder 3 5 4 Monochlorobenzen...

Page 29: ...f any damage has occurred to the packaging and device during transport Do not use a device clearly damaged during transport but rather contact the manufacturer in order to resolve the situation If the...

Page 30: ......

Page 31: ......

Page 32: ...Dinel s r o U Tescomy 249 760 01 Zl n Czech Republic Phone 420 577 002 002 Email sale dinel cz www dinel cz Find the updated version at www dinel cz version 08 2017 05 2020...