background image

DTK-120X12

User Guide 

DITEK CORPORATION

One DITEK Center 1720 Starkey Road Largo, Fl 33771

1-800-753-2345 www.diteksurgeprotection.com

DITEK

Surge Protection

MODULE

STATUS

DTK-DFXXXM

XXXVAC

R

ENERGIZED

GROUNDED

GOOD

REPLACE

MADE IN USA

DEFLECTOR

SERIES

Pat. www.diteksurgeprotection.com/patents

Model: DTK-DFXXXM     SPD TYPE 2CA

Electrical Ratings: XXXVAC, 20A, 50/60 Hz, Single Phase  

Nominal Discharge Current Rating: (In): 10kA, SCCR: 10kA

MCOV Rating: 150 L-N, 150 L-G

VPR: 600 L-N, 600 L-G

Suitable for use on a circuit capable of delivering not more than

10,000 rms symmetrical amperes, XXX Volts maximum when pro-

tected by a 20 ampere circuit breaker rated 120 volts minimum.

Convient a des circuits produisant au plus 10,000 A eff.

WARNING - SHOCK HAZARD - DO NOT OPEN

AVERTISSEMENT - RISQUE DE CHOC

NE PAS OUVRIR

C

UR

US

Summary of Contents for Deflector Series

Page 1: ...TK DFXXXM SPD TYPE 2CA Electrical Ratings XXXVAC 20A 50 60 Hz Single Phase Nominal Discharge Current Rating In 10kA SCCR 10kA MCOV Rating 150 L N 150 L G VPR 600 L N 600 L G Suitable for use on a circ...

Page 2: ...isant au plus 10 000 A eff WARNING SHOCK HAZARD DO NOT OPEN AVERTISSEMENT RISQUE DE CHOC NE PAS OUVRIR C U R US DITEK R DTK 2MHLP DTK 2MHTP 5 12 24 36 48 75 130 MODULAR SURGE PROTECTION VOICE DATA SIG...

Page 3: ...pply wire to the LINE IN lug at the LINE side 6 Connect the Ground Neutral and Phase wires from the LOAD side to the control panel or your equipment s AC inputs Note Tightening torque for the 120VAC p...

Page 4: ...this device in series between the field wiring and the control panel supply wiring These Low Voltage protection circuits are equipped with a removable plug and header assembly Simply remove the plug...

Page 5: ...ng These Low Voltage protection circuits are equipped with a removable plug and header assembly Simply remove the plug from the header terminate your wires then replace the plug making sure it seats a...

Page 6: ...odule is installed the audible alarm will be cancelled The red polarizing keys insure that the correct voltage module will mate with its correct base WARNING When the DTK 120M module has gone end of l...

Page 7: ...ow voltage surge module into the corresponding position according to your connection circuits When a DTK 2MHTP tele communications surge module has expired gone end of life there will be interference...

Page 8: ...Center 1720 Starkey Road Largo Fl 33771 1 800 753 2345 www diteksurgeprotection com Doc INT 100190 001 Part No 191635 Rev 2 DTK 120X12 THIS PAGE LEFT INTENTIONALLY BLANK Drawn By B Aycock 5 7 2020 Rev...