DMX-Universal-Demux 

 
 

 
 

 
 

User Manual 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for DMX-Universal-Demux

Page 1: ...DMX Universal Demux User Manual...

Page 2: ...from 12V up to 24V Different operation modes By jumper the operating mode of the DMX Universal Demux can be selected Available are the operation modes Threshold Bin r PWM Servo Strobo Controllable via...

Page 3: ...thout load Protocol DMX512 RDM DMX channels 1 or 8 channels depends on selected mode Output 8 open collector outputs max 500mA DMX FAIL HOLD 0 100 Operation mode Threshold switches at 50 Binary 8 Bit...

Page 4: ...DMX Universal Demux 4 Connection...

Page 5: ...ultifunctional display In the normal operation mode the LED lights non stop In this case the device is working If the LED is permanently dark there is no DMX512 input signal Furthermore the LED signal...

Page 6: ...s 127 128 no jumper placed In threshold mode hysteresis 127 128 8 successive DMX channels are received The belonging output will be set on OFF if the received value is between 0 and 127 and set on ON...

Page 7: ...ON 11011011B Output 5 OFF 01001101B Output 5 ON 11011011B Output 6 OFF 01001101B Output 6 OFF 11011011B Output 7 ON 01001101B Output 7 ON 11011011B Output 8 OFF 01001101B Output 8 ON 11011011B Strobe...

Page 8: ...he PWM Frequency is ca 175 Hz Servo Control only jumper J4 is placed The DMX Universal Demux receives 8 successive DMX Channels and outputted a signal for triggering customary servos Thereby each outp...

Page 9: ...second as soon as the DMX value is 170 or higher After that the DMX value must fall below 85 again to trigger a switching pulse again DMX channel DMX value Function 1 8 0 170 Output OFF 171 255 Output...

Page 10: ...be set to OFF A DMX start address set by the address switches is always prior This device supports the following RDM commands Parameter ID Discovery Command SET Command GET Command ANSI PID DISC_UNIQU...

Page 11: ...device serial number GET Send PDL 0 Receive PDL 21 21 Byte ASCII Text IDENTIFY_MODE PID 0xD402 Stellt den Mode ein der mit IDENTIFY_DEVICE ausgef hrt wird GET Send PDL 0 Receive PDL 1 1 Byte IDENTIFY_...

Page 12: ...ct power supply Set DIP switch 1 up to 10 to ON Turn on device connect power supply The LED lights up 20x during ca 3 seconds While the LED lights up set DIP switch 10 to OFF Now the Factory Reset is...

Page 13: ...DMX Universal Demux 13 Dimensions All details in mm...

Page 14: ...DMX Universal Demux 14 Equipment Top hat rail housing 700 Power supply 12V...

Page 15: ...the EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with ap...

Page 16: ...he board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it...

Page 17: ...ems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to poi...