background image

I

 

SERVICE

United States

EXECUTIVE OFFICE

DOMETIC  SALES CORP.

2320 Industrial Parkway
P.O.  Box 490
Elkhart,  IN 46515
(219) 294-2257
TWX 810-294-2257

SALES OFFICES

DOMETIC  SALES CORP.
14441 Bonelli Street

City of Industry. CA 91746
(313) 968-9431
TWX 910-584-1323

DOMETIC  SALES CORP.

5755 So. Hoover Rd. Unit 2
Wichita, KS. 67215
(316) 522.1518
TWX 910-741-0000

DOMETIC  SALES CORP.
East Oak Ridge Drive
Rt. 9, Box 17A
Hagerstown, MD 21740

(301) 797-0826
TWX 710-853-6821

DOMETIC  SALES CORP.
7895 S.W. Hunziker Rd.
Portland, OR 97223

(503)  620-9510
TWX 910-458-8838

DOMETIC  SALES CORP.

902 Avenue R
Grand Prairie, TX 75050
(214) 641.4277
TWX 910-866-4626

Canada

EXECUTIVE OFFICE

DOMETIC  CANADA INC.

2316 South Service Road West
Oakville.  Ontario L6J  5A2
(416) 827-9811
TELEX 06-982234

SALES OFFICES

DOMETIC  CANADA INC.

6019 3rd Street SE.
Calgary, Alberta T2C  1 R4
(403) 279-2669
TELEX 038-21885

DOMETIC  CANADA INC.
1650 Rue Haggerty
Drummondville. Ouebec  J28 6W4

(819) 472.1182
TELEX 05.838532

September 1980

820 88 1503

OPERATING AND

INSTALLATION INSTRUCTIONS

MODEL

RM211

OPERATION BY L.P. GAS OR ELECTRICITY (DUAL VOLTAGE, 12/110V)

FOR USE IN A RECREATIONAL VEHICLE

Summary of Contents for RM211

Page 1: ...ALES CORP 7895 S W Hunziker Rd Portland OR 97223 503 620 9510 TWX 910 458 8838 DOMETIC SALES CORP 902 Avenue R Grand Prairie TX 75050 214 641 4277 TWX 910 866 4626 Canada EXECUTIVE OFFICE DOMETIC CANADA INC 2316 South Service Road West Oakville Ontario L6J 5A2 416 827 9811 TELEX 06 982234 SALES OFFICES DOMETIC CANADA INC 6019 3rd Street SE Calgary Alberta T2C 1 R4 403 279 2669 TELEX 038 21885 DOME...

Page 2: ...hes This is the minimum height which can be allowed over the condenser fins Wherever possible this height should be increased by up to 11 inches the more ventilation you provide the better the performance you can expect from the refrigerator The refrigerator should be installed in accordance with the illustra tions on page 3 Both the flue gases and the ventilation air must pass to the outside and ...

Page 3: ...nt VT24 II and 1 lower vent VT24 I Upper vent opening 17 1 2 x 7 A Upper Vent INSTALLATION ABOVE FLOOR LEVEL FIG 2 Recess in trailer to house refrigerator Height 22 1 2 FIG 3 ITE When necessary the underside of the top of the recess should be cut away locally at the front to give clearances for the travel catch support at one side and the upper hinge arm at This is the minimum height allowable Whe...

Page 4: ...nto a circulating flow of hydrogen gas If the evaporator is not level the liquid may accumulate forming pockets which can impair the gas circulation or block it completely in which case cooling will stop When the trailer is stationary for a period it must be level so that the refrigerator can operate properly When the trailer is being parked therefore the level should be checked preferably by mean...

Page 5: ... any thing else Frost will form gradually on the cooling fins and in and on the frozen food compartment It is a mistake to assume that an accumulation of frost gives a colder cabinet for the most efficient and economical operation the refrigerator should be defrosted regularly about every ten to fourteen days depending on the particular conditions of use Remember to level the trailer when stopping...

Page 6: ...e heater in its metal pocket Bend back the retaining wire clip at the top of the pocket and lift the heater from the pocket at the same time withdrawing its leads from the armoured sleeve Check that the new heater is of the correct type then fit it in the metal boiler pocket at the same time threading the three leads through the armoured sleeve This operation will be assisted if the ends of the le...