background image

Power Supply

Properly earthed 3 pin single-phase power is required.

Swing Gate Opener Installation Instructions

  SGO-1V4 Elite

®

Kit Contents

1. 1 x Gate Drive Unit SGO-1V4

2. 1 x Drive Arm Extension

3. 1 x Safety Slave Arm

4. 1 x Gate Mounting Bracket

5. 4 x Plastic Washer

6. 2 x Shoulder Screw 1615

7. 2 x Hex Head Screw M10 x 20

8. 2 x Spring Washer

9. 2 x Flat Washer

Tools Required

• Adjustable Wrench

• Socket set

• Drill

• Screwdrivers

• Marker Pen

WARNING!

 

A portable power generator is not 

recommended due to spikes, surges and fluctuations in 

the supply.

CAUTION:

 

do not use any cables which carry green/

yellow wires as this signifies earth, and do not comply 

with electrical authority regulations.

Initial Check

Before commencing installation, check the following:

a. The gate moves freely by hand for the full length of open and close

travel.

b. The pier or post for mounting must be of solid construction (Brick, solid

timber or steel). It must bear most of the force applied by the drive unit.

c. A weatherproof 240V 10A general purpose power point should be

available within one metre of the pier/post. If two Elite

®

 gate openers

are required, provision for underground cabling should be made from

one post to the other.

d. Ensure sideroom clearance is adequate. If there is not enough sideroom

available, the Minimum Sideroom Kit is required.

Doc #:   160043_01

Part #:   13408

Released: 15/12/14

2

7

8

9

6

5

4

3

1

Gate in open 

position

Mount 

distance

Sideroom 

clearance

Hinge 

distance

Wall/Pier

Mount 

Distance

Hinge Distance

0

50

100

125

150

180

200

220

mm

Sideroom clearance

90

470

470

470

470

470

470

465

460

mm

120

450

470

480

470

465

460

435

425

mm

140

470

465

470

465

460

440

420

390

mm

200

470

465

445

430

400

350

390

250

mm

a. The mount distance of the Drive Unit should be recorded. This value will

be used later.

b. The mount distance for the drive unit and the hinge distance for the

gate can be selected to optimise the sideroom clearance.

NOTE: 

If the gateway slopes away from pier/post, make sure an allowance 

is made for clearance of the drive arm extension and slave arm to not touch 

the ground.

c. Mount drive unit using four (4) 10mm loxins or dynabolts and the

mounting template within this document.

d. Make sure that the Drive Unit is mounted at an appropriate height from

the ground - allow minimum 35mm clearance for drive arm extension.

NOTE: 

If the gate is already installed, measure the hinge distance and use 

this table to optimise the mount distance.

Mounting the Drive Unit 

Reviews: