background image

 

 

 

 

 

 

Manuale HL.ACFP - Ver. 19.09

 

 

 

      

                                                                    

 

 

 

 

 

 

 

 

          

 

                                                         

 

 

 

 

 

 

 

 

          

 

         

 

 

 

 

 

 

 

 

 

 

 

                        

Pag.

1

 

 

 

 

 
 

HL.ACFP 

Manuale d’istruzioni 

 

 

LETTORE BIOMETRICO E LETTORE DI CARTE ANTI-VANDALO 

MONO O BI-CANALE, STANDALONE O WIEGAND 

 

 

Summary of Contents for HL.ACFP

Page 1: ...Manuale HL ACFP Ver 19 09 Pag 1 HL ACFP Manuale d istruzioni LETTORE BIOMETRICO E LETTORE DI CARTE ANTI VANDALO MONO O BI CANALE STANDALONE O WIEGAND ...

Page 2: ...de al numero di telefono 030 9913901 Presentazione del prodotto Il lettore di impronte digitali DOMOTIME HL ACFP è un dispositivo di controllo accessi ha un design semplice operazioni facili e alta affidabilità Il circuito interno è resinato che gli conferisce una resistenza totale all acqua IP 66 Il dispositivo consente l apertura o la chiusura di un relè mediante l uso di un impronta digitale o ...

Page 3: ... KHz EM Utenti registrabili 1000 impronte digitali e 2000 carte tag Connessione cablaggio Uscita relè Standalone Uscita Wiegand pulsante d uscita allarme Relè Tempo chiusura relè Regolabile da 1 a 99 secondi Carico massimo 2 Amp Interfaccia Wiegand 26 bits Temperatura di esercizio 40 C 60 C Umidità di esercizio 20 RH 90 RH Materiale Lega di zinco Grado di protezione IP IP66 Dimensioni e peso 128 x...

Page 4: ...e funzioni ausiliarie di comando e o allarme direttamente dal dispositivo HL ACFP pagina 5 La modalità Wiegand permette al HL ACFP di commutare dei contatti NO NC per comandare QUALSIASI DISPOSITIVO da remoto tramite una scheda di controllo Il lettore quindi non gestirà i contatti direttamente ma lo farà attraverso una scheda di decodifica garantendo affidabilità e sicurezza all intero sistema gra...

Page 5: ...ta relè contatto normalmente chiuso 2 Amp max Cablaggio modalità Standalone Input e Output opzionali Giallo Input_1 Pulsante per l apertura chiusura del relè Grigio Output_Alarm Output Polo negativo per allarme Marrone Sensor Input Sensore di apertura normalmente chiuso ATTENZIONE Nella modalità Standalone nel caso in cui l alimentazione del nostro prodotto sia la medesima che va ad alimentare l a...

Page 6: ...modifcare il codice per una maggiore sicurezza Operazioni base Modificare Master Code Descrizione funzionamento Combinazione tasti Entrare nella modalità programmazione Digitare Master Code Modificare Master Code Master Code è qualsiasi numero composto da 6 cifre Digitare Nuovo Master Code Ripetere Nuovo Master Code Uscire dalla modalità programmazione Aggiungere utenti Aggiungere un impronta digi...

Page 7: ...a o più carte tag o una o più impronte digitali Avvicinare al device una o più carte tag al lettore o leggere sul lettore una o più impronte digitali Uscire dalla modalità programmazione Leggere la Master Add Card sul lettore Rimuovere utenti Rimuovere un impronta digitale attraverso l impronta stessa Descrizione funzionamento Combinazione tasti Entrare nella modalità programmazione Digitare Maste...

Page 8: ...vato un numero definito di carte tag o impronte digitali Programmazione opzione 1 Seleziona apertura chiusura del relè con rilevamento SOLO carte tag Descrizione funzionamento Combinazione tasti Entrare nella modalità programmazione Digitare Master Code Selezionare apertura chiusura del relè con rilevamento SOLO carte tag Uscire dalla modalità programmazione Utilizzo opzione 1 Aprire chiudere il r...

Page 9: ... nella modalità programmazione Digitare Master Code Modalità monostabile Predefinito 5 secondi Il tempo di apertura del relè può essere impostato da 1 a 99 secondi 1 50 mS Digitareun numero da 1 a 99 Uscire dalla modalità programmazione Impostare modalità apertura relè BISTABILE Descrizione funzionamento Combinazione tasti Entrare nella modalità programmazione Digitare Master Code Modalità bistabi...

Page 10: ...imenti continuerà a suonare per il tempo definito dall allarme Imposta rilevamento apertura porta Quando viene utilizzato con un contatto magnetico opzionale o un contatto magnetico incorporato della serratura se la porta viene aperta normalmente ma non chiusa dopo 1 minuto il cicalino interno emetterà un segnale acustico automatico per ricordare alle persone di chiudere la porta Il segnale acusti...

Page 11: ...uscirebbe a comandare i contatti NO NC e di conseguenza ad abilitare nessun dispositivo ad esso collegato Per poter utilizzare la modalità Wiegand del lettore biometrico HL ACFP è necessario collegarlo ad una scheda di decodifica remota Attenzione Prima di poter aggiungere un utente sulla scheda di decodifica è necessario memorizzarlo sul lettore biometrico Cablaggio modalità Wiegand Colore cavo N...

Page 12: ...asi numero da 1 a 1000 ATTENZIONE L impronta digitale deve essere pulita per evitare errori di lettura Digitare ID Utente Leggere impronta digitale sul lettore Ripetere la lettura dell impronta digitale sul lettore Uscire dalla modalità programmazione Aggiungere una carta tag assegnandone il primo ID Utente disponibile Descrizione funzionamento Combinazione tasti Entrare nella modalità programmazi...

Page 13: ...e un impronta digitale o una carta tag utilizzando l ID Utente Digitare ID Utente Uscire dalla modalità programmazione Rimuovere tutti gli utenti Descrizione funzionamento Combinazione tasti Entrare nella modalità programmazione Digitare Master Code Rimuovere tutti gli utenti Digitare Master Code Uscire dalla modalità programmazione Rimuovere una o più carte tag o una o più impronte digitali utili...

Page 14: ...rà 4 volte e tornerà alle normali funzioni Attenzione Il bottone d uscita potrà ugualmente attivare disattivare l uscita Ripristino delle funzioni di fabbrica e memorizzazione Master Cards Attenzione questa operazione riporterà le impostazioni a livello di fabbrica non eliminirà le utenze già abilitate per farlo è necessario eseguire la seguente operazione Rimuovere tutti gli utenti Descrizione fu...

Page 15: ...low Description Model Anti vandalism fingerprint and card reader HL ACFP Complies with the legislative regulations as in the following directives EN 55022 2010 AC 2011 EN 55024 2010 A1 2015 This statement is issued under the sole responsibility of the manufacturer and if applicable of his authorized representative ____________________________________________________________________________________...

Page 16: ...Manuale HL ACFP Ver 19 09 Pag 16 Domotime srl Via Monico 9 25017 Lonato d G BS Italy Tel 39 030 9913901 Fax 39 030 2070611 Skype domotime email info domotime com www domotime com ...

Page 17: ...Manuale HL ACFP Ver 19 09 Pag 17 HL ACFP Instruction manual ANTI VANDALISM FINGERPRINT READER AND CARD READER SINGLE OR DUAL CHANNEL STANDALONE OR WIEGAND ...

Page 18: ...ems Domotime Srl has a customer service that responds to the phone number 030 9913901 Product Overview The DOMOTIME HL ACFP fingerprint reader is an access control device has a simple design easy operation and high reliability The internal circuit is resin which gives a total resistance to water IP 66 The device allows the opening or closing of a relay by the use of a fingerprint or the detection ...

Page 19: ...gs 125 KHz EM Recordable users 1000 fingerprints and 2 000 cards tags Cable connection Relay output Standalone Wiegand output output button alarm Relay Relay closing time Adjustable from 1 to 99 seconds Maximum load 2 Amp Wiegand interface 26 bits Operating temperature 40 C 60 C Operating Humidity 20 RH 90 RH Material Zinc alloy Ingress protection IP66 Dimensions and weight 128 x 48 x 26 300 g ...

Page 20: ...d to use auxiliary functions of command and or alarm device directly from HL ACFP page 5 The Wiegand mode allows the HL ACFP of switching of the NO NC contacts for controlling ANY DEVICE remotely via a control board The reader then will not handle contacts directly but will do so through a decoder card guaranteeing reliability and security to the entire system thanks to the communication Wiegand e...

Page 21: ... output normally closed contact 2 Amp max Standalone mode Wiring Input and Output Options Yellow input_1 Button for the opening closing of the relay Grey Output_Alarm Output Negative pole for Alarm Brown Sensor Input opening sensor normally closed WARNING In the Standalone mode in the case where the power supply of our product is the same one that goes to feed the accessory on auxiliary contacts e...

Page 22: ...ler of the device must know Default Value Master Code 123456 We recommend arises to change the code for added security Basic Operations Change Master Code Working description Keystroke combination Digiting the programming mode Digit master code Change Master Code Master Code is any number consists of 6 digits Digit New Master Code Repeat New Master Code Exit programming mode Add users Add fingerpr...

Page 23: ...Card on the reader Add one or more cards tags or one or more fingerprints Bring the device one or more cards tags reader or read one or more fingerprints on the reader Exit programming mode Read the Add Master Card on the reader Remove users Remove a fingerprint through the same footprint Working description Keystroke combination Digiting the programming mode Digit master code Remove fingerprint u...

Page 24: ...n 4 only after detecting a defined number of cards tags or fingerprints Programming option 1 Select the opening closing of the relay ONLY detection card tag Working description Keystroke combination Digiting the programming mode Digit master code Select opening closing of the relay with detection ONLY cards tags Exit programming mode Use option 1 Open close the relay card tag Open close the relay ...

Page 25: ...tion Keystroke combination Digiting the programming mode Digit master code Monostable mode Default 5 2 The relay opening time can be set from 1 to 99 seconds 1 50 mS Digitareun number from 1 to 99 Exit programming mode Set relay opening modes LATCHING Working description Keystroke combination Digiting the programming mode Digit master code bistable mode Set the opening closing of the relay in the ...

Page 26: ...ensed users otherwise it will continue to play for the time defined by the alarm Set sensing door opening When used with an optional magnetic contact or a magnetic contact of the built in lock if the door is normally open but not closed after 1 minute the internal beeper will emit an automatic beep to remind people to close the door The acoustic signal can be stopped by closing the door or by auth...

Page 27: ...al fingerprint reader would not be able to control the NO NC contacts and consequently to enable any device connected to it In order to use the Wiegand mode of the fingerprint reader HL ACFP it is necessary to connect to a remote decoder card Warning Before you can add a user on the decoder card you must store the fingerprint reader Wiegand mode Wiring Cable color Contact name Function Red 12 Vdc ...

Page 28: ...D is any number from 1 to 1000 WARNING The fingerprint must be clean to prevent false readings Digit User ID Read the fingerprint reader Repeat reading your fingerprint on the reader Exit programming mode Add a card tag assigns the next available User ID Working description Keystroke combination Digiting the programming mode Digit master code Add card tag assigning the first available ID Read the ...

Page 29: ... Remove a fingerprint or a card tag using the User ID Digit User ID Exit programming mode Remove all users Working description Keystroke combination Digiting the programming mode Digit master code Remove all users Digit master code Exit programming mode Remove one or more cards tags or one or more fingerprints using the Delete Master Card provided Working description Keystroke combination Digiting...

Page 30: ...t the green LED will flash 4 times and will return to normal operation Warning The exit button can also activate deactivate the output Restoring the factory and storage functions Master Cards Warning This will return the settings to the factory level do not delete your utilities already enabled to do that you need to perform the following operation Remove all users Working description Keystroke co...

Page 31: ...escription Model Anti vandalism fingerprint and card reader HL ACFP Complies with the regulations as in the legislative Following directives EN 55022 2010 AC 2011 EN 55024 2010 A1 2015 This statement is issued only under the responsibility of the manufacturer and if applicable of His authorized representative _________________________________________________________________________________________...

Page 32: ...Manuale HL ACFP Ver 19 09 Pag 32 Via Monico 9 25017 Lonato d G BS Italy Tel 39 030 9913901 Fax 39 030 2070611 Skype domotime email info domotime com www domotime com ...

Reviews: