background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AD Nano 

 

USER MANUAL 

 

V1 May 15 

 

Summary of Contents for 30105519-1313

Page 1: ...AD Nano USER MANUAL V1 May 15...

Page 2: ...npacking and unit placement 3 01 02 Connecting to power supply Optional interfacing 4 01 Turning extractor on 5 01 02 Important safety notes Safety labels 2 01 02 Cleaning the unit Filter replacement...

Page 3: ...Overview Mains Isolation Switch Control Panel Lockable Castors Door Latches Combined Filter Combined Filter Lever Pre Filter 01 1...

Page 4: ...Overview Mains Inlet Signal Cable Inlet Optional Exhaust Outlet Air Outlet Air Inlet 02 1...

Page 5: ...Overview Main Isolation Switch Company Branding Filter Blocked Filter 75 full System Running Clean 03 1...

Page 6: ...moving the pump motor access panel 2 Use only as described in this manual 3 Connect the system to a properly grounded outlet Dangers to eyes breathing and skin Once used the filters within the AD Nano...

Page 7: ...acture Relevant approval markings logos PLEASE NOTE If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment maybe compromised Fire Risk Warning...

Page 8: ...t should be used and with regard to appropriate safety precautions See Appendix for product weight details Ensure that 500 mm space is available around any vented panels on the extractor to ensure ade...

Page 9: ...nit should not be connected to the mains The supply cord should only be replaced by a BOFA engineer as an electrical safety test may be required after replacement The AD Nano MUST be connected to a pr...

Page 10: ...PCB Red cable V Black cable V When the extractor is provided with the correct DC voltage the motor will start and maintain the set flow rate Refer to section 5 for how to set the flow when the DC volt...

Page 11: ...images below to identify the switch your AD Nano unit uses Powder Coated Version Press the main isolation switch to the On position Refer to section 1 for switch location by depressing the I side of t...

Page 12: ...prevent build up of dust and overheating of the unit Filter Information A log of filter changes should be maintained by the user The filters require attention when the display shows the configuration...

Page 13: ...orn when changing filters To remove and replace the pre filter follow the procedure detailed below 1 Isolate the electrical supply to the unit 2 Open the door of the unit 3 Remove the lower pre filter...

Page 14: ...tured from non toxic materials Filters are not re usable cleaning used filters is not recommended The method of disposal of the used filters depends on the material deposited on them For your guidance...

Page 15: ...l Below 60dB A at typical operating speed Size Metric mm Imperial inches Height 797 31 4 Depth 435 17 2 Width 377 14 9 Filters Filter Type Surface area Weight Efficiency Pre Filter 6 0 m F8 Combined F...

Page 16: ...Creekmoor industrial Estate Poole Dorset BH17 7DU UK Phone 44 0 1202 699 444 BOFA Americas 303 S Madison Street Staunton Illnois 62088 USA Phone 1 618 205 5007 BOFA International GmbH Sudring 62 D 21...