P:\INSTALLATION INST\DORMA\INST-AC217 (version 2).vsd REV A 08-09 Page 1
AC217 STAND-ALONE KEYPAD
INSTALLATION INSTRUCTIONS
Try the new code: Press 1493#
Basic Programming:
1. Enter Programming Mode
Power unit up with (LPJ) jumper in the ON position, remove, replace
jumper to OFF position (puts you in the program mode).
Enter “09876#”
New Master Code is 9876.
2. Program User Code
Enter 9876* followed by 1 user ID number (01-99) pin number #
Example: 9876 * 1 01 7412# (this is user 01 with pin number 7412).
User Number from 1 – 99. PIN code 4-8 digits.
3. Set Main Relay Time
Press 40 05 # *. Time (1-999 sec.)
Additional Programming Optional:
Delete User
Enter Master Code * 1 User Number # *. Deletes user.
Change Master Code
Enter Master Code * 0 New Master # *. Master code is changed.
Reset to factory default settings
Enter Master Code * Press 8901# *. Erases all programming except
Master Code.
AC217 EXAMPLE PROGRAMMING
Basic Programming:
The following steps will set the AC217 to:
User 02 PIN code 1493
Unlock for 5 seconds
Programming:
1. Enter 9876* 1 02 1493#
2. Enter 40 05# *
Action
Enters Programming Mode and assigns User 02 the PIN
Code of 1493, Master Code is 9876.
LPJ JUMPER
DORMA ARCHITECTURAL HARDWARE
DORMA Drive, Drawer AC Reamstown, PA. 17567
(800) 523-8483 * Fax: (800) 274-9724
www.dorma-usa.com