background image

snapchat: dospel.com

www.dospel.com

twitter.com/dospel_com

dospel@dospel.com

+48 (34) 370 30 00

facebook.com/Dospel.Wentylacja

Below documentation shall be kept by user!
In case of not following the conditions of this document, the warranty expires.

MAINTENANCE MANUAL

WARRANTY CARD

AIR HANDLING UNIT

luna 200

rew. 2.02.2018

EN

Summary of Contents for luna 200

Page 1: ...ospel dospel com 48 34 370 30 00 facebook com Dospel Wentylacja Below documentation shall be kept by user In case of not following the conditions of this document the warranty expires MAINTENANCE MANUAL WARRANTY CARD AIR HANDLING UNIT luna 200 rew 2 02 2018 EN ...

Page 2: ...xploitation conditions 2 2 Assembly of siphon out condensate 2 3 Connecting to power grid 3 STARTING THE UNIT 3 1 General remarks 3 2 Starting the unit 3 3 Summer mode 3 4 Exploitation recommendation 3 5 Controller maintenance manual 4 WARRANTY 3 3 3 5 5 6 7 9 9 9 10 11 12 12 luna 200 EN ...

Page 3: ...tched on without opening the casing 1 2 Technical data Chart 1 Technical specification 148 mm 1108 mm x 564 mm x 494 mm Dimension Connection diameter Air flow 100Pa Disposal compression Max power consumption Heat recovery efficiency Power supply voltage Power Motor supply voltage Motor rotational speed Type of motor s bearing Roller Acoustic pressure Insulation class International Protection Ratin...

Page 4: ...holding the connectors It may result in leakage and damage to the device Fig 1 Nominal dimensions LUNA 200 1108 564 459 8 171 4 Ø148 494 450 870 Fig 2 Flow efficiency characteristics LUNA 200 3 Airlfow m h Pressure Pa 50 0 100 150 250 200 300 350 400 0 100 200 300 400 500 luna 200 EN ...

Page 5: ...pness in the room or damage to the unit WARNING 1 Ventilation installation and other belonging elements must be in accordance with Polish Norms referring to ventilation in residential buildings 2 The unit is not destined for drying the unseasoned houses 3 In case of damage to elements arising from not following the above instructions they will be not repaired under warranty 4 Due to design reasons...

Page 6: ...e pipe siphoning out the condensate Exemplary way of conneting the pipe is shown below The pipe should have adequate diameter to the stub pipe 16 mm It shoud be bent into letter U and suffused with water until stabilizing its level Shipon should be palced around 120 mm from the unit and radius should not be less than R 30 mm Given measures should be taken as minimal Unit is sold with siphon and pi...

Page 7: ...properly led to connection box with in accordance with schemes Such installation should be secured with proper fuse overcurrent braker etc All electrical matter should be perfomed by authorized person WARNING Prior to maintenance work or repairs unit should be disconnected from the power outlet by pulling the plug out In case of damaging the wire replacement can only be performed by authorized per...

Page 8: ...AC 50Hz Luna 200 5x0 5 5x0 5 5x1 OFF HI LO MED DOSPEL L L LL LL LL LL N N N N PE PE PE PE C C LM LM LM LM LH LH LH LH N PE LO M H OFF M exhaust 230 max 70W M intake 230 max 70W 3 gear controller WARNING Supply voltage VAC 50Hz the current protection should be selected based on the device s power 3 gear controller connection box connection box luna 200 EN ...

Page 9: ... no damage 3 Place unit in wanted place 4 Connect 3 gear controller 5 Connect connection cord to connection box in accordance with schemes then to 3 gear controller 6 With 3x1 5 mm2 secured by fuse 230v 50Hz connect to 3 gear controller 7 Turn on the unit switching to wanted gear LO MED HI 8 Turn off the unit OFF Once all above is performed the unit can be used Usage and maintenance When proprely ...

Page 10: ...s It is only recommended for testing but no longer than 10 minutes 3 3 Summer mode Luna 200 is equipped with baypass which is activated by lever placed on the casing The moment when bypass is opened heat exchange does not take place To open bypass turn lever by 90 degree counterclockwise Bypass helps to cool ventilated rooms with use of i e GWC Fig 5 Manner of replacing filters Exchanger Filters C...

Page 11: ...impeller Do not clean with water do not put in water Solid dirt can be cleaned with denaturated alcohol Prior to placing back dry well Control of condensate s stub pipe Stub pipe can become dirty overtime by fixed particles brought by air It is recommended to periodically check by flushing with water stub pipe patency Clean if needed Cleaning intake and exhaust Unit is a part of a whole system the...

Page 12: ...accordance with maintenance conditions attached to this warranty This warranty is valid only in territory of Poland Warranty Dospel guarantees repairs witin 2 years from date of purchase Claims resulting from warranty are brought up with the day of purchase They expire with the end of warranty of a given product counted from the day of purchase Warranty obliges Dospel to remove failures caused by ...

Page 13: ...ctly to Dospel main office Replecement under warranty 1 Only when removing the fault is impossible or when removing the fauld is too expensive after Dospel evaluation 2 When product is repaired for the fourth time during warranty period due to the same production fault When specific unit is unavailable a new one with similar parameters can be dispensed in exchange After replecement the warranty pe...

Page 14: ... SEC warm climate SEC range average climate SEC range cold climate SEC range warm climate Device type Type of drive Heat recovery system Thermal efficiency of heat recovery Maximum flow rate Power consumption of fan drive Sound power level L wa Internal leakage rate Filter change warning signal Website Annual electricity consumption 2 per 100 m Control factor CTRL The annual heating saved cold cli...

Page 15: ...wa tel 48 34 365 98 43 fax 48 34 360 97 00 e mail dospel dospel com www dospel com Dospel reserves the right to introduce any changes regarding its products resulting from ongoing technical development Dospel shall not be liable for printing errors ...

Reviews: