SRI3/I2

Codice Ordinazione  -  Code Commande  -  Order code:

9SRI3/I2 – 9SRI3/I2RS485 – 9SRI3/I2CC -9SRI/I2CCRS485

Dim: 6 DIN

 FIG1

 FIG2

 FIG3

 FIG4

MU1235 REV 7

ATTENZIONE- WARNING- ATTENTION- Gli IMD non devono essere collegati in parallelo– IMDs shall not be connected in parallel- Les CPI ne 
doivent pas être connectés en parallèle

Summary of Contents for SRI3/I2

Page 1: ...I3 I2 9SRI3 I2RS485 9SRI3 I2CC 9SRI I2CCRS485 Dim 6 DIN FIG1 FIG2 FIG3 FIG4 MU1235 REV 7 ATTENZIONE WARNING ATTENTION Gli IMD non devono essere collegati in parallelo IMDs shall not be connected in parallel Les CPI ne doivent pas être connectés en parallèle ...

Page 2: ...VA Sistema di distribuzione Tipo di IMD IT AC DC IMD Categoria sovratensione Grado inquinamento CAT II 2 Norme di Riferimento IEC 61557 8 IEC 61326 2 4 Grado protezione IP40 frontale IP20 morsetti Temperatura di funzionamento 10 50 C Temperatura di stoccaggio 20 80 C Massima altitudine 2000m Sezione massima terminali 2 5mm Misura dell Isolamento Ran Valore di Risposta 5KΩ 2MΩ Rf resistenze misurab...

Page 3: ...t 50kΩ AUTOTEST Tempo entro cui effettuare un autotest 0 72H default 0 R3 Funzione del terzo relè A F scatta se o A o F scattano D scatta quando interviene un allarme diagnostico generico temperatura tensione o discconnessione trasformatore T scatta solo per allarme temperatura U scatta solo per allarme tensione DIS scatta solo per allarme di disconnessione trasformatore default A F DELAY ritardo ...

Page 4: ...0Vdc for SRI3 I2CC 10VA Distribution System Type of IMD IT AC DC IMD Overvoltage category Pollution degree CAT II 2 Reference Standard IEC 61557 8 IEC 61326 2 4 Protection degree IP40 Frontal IP20 Terminal Working temperature 10 50 C Storage temperature 20 80 C Maximum altitude 2000m Max terminal section 2 5mm Insulation Measure Ran Response value 5KΩ 2MΩ Rf measurable resistance 1KΩ 10MΩ Tan in a...

Page 5: ...sistance 5kΩ 2MΩ default 50kΩ AUTOTEST Time to carry out a self test 0 72H default 0 R3 Function of 3rd relay A F if A or F will be on trip D it will be on trip if there is a diagnostic alarms temperature voltage or transformer disconnection T it will be on trip only for temperature alarm U it will be on trip only for voltage alarm DIS it will be on trip only for alarm of transformer disconnection...

Page 6: ...lance sont constamment affiché sur l écran verte les suivants paramètres Résistance isolement RAN Tension ligne seulement si les seuil d alarme sont différents de zéro Symbole du typer de tension Température interne en C seulement si le seuil d alarme thermique est différent de zéro Représentation graphique en histogramme de la résistance d isolement compris entre les 2 seuils réglés alarme et déf...

Page 7: ... test 0 72H default 0 R3 function of 3 relais A F si A ou F déclenchent D il va déclencher s il y a une alarme de diagnostic T il va déclencher seulement pour l alarme de temperature U il va déclencher seulement pour l alarme de tension DIS Il va déclencher seulement pour l alarme de déconnexion du transformateur default A F DELAY Délai en secondes pour le déclechement de FAULT 0 9999Sec default 0...

Page 8: ...ICA TECHNICAL APPENDIX ANNEXE TECHNIQUE IT Tempo di risposta in relazione alla capacità parassita EN Response times in relation to system leakage capacitances FR Temps de réponse par rapport à la capacité parasitaire ...