background image

ZL106476 

A                         COMPANY

www.neptune1.com

PUMP SOLUTIONS GROUP

DOVER

A                            COMPANY

NEPTUNE

MEMBER OF

TM

 

 

 

 
 

 

SERIES E & H DRUM MIXERS 

 

ATTENTION: TO INSURE SAFE AND EASY USE OF YOUR NEPTUNE MIXER, 

READ THESE INSTRUCTIONS BEFORE USING. 

 

Description 

 

Series E & H Mixers are designed for economical mixing of 
closed head steel drums. The mixer mounts by screwing 
into the 2” bung opening. The folding propeller collapses to 
allow entry through the 2” bung and opens when operating 
to provide thorough mixing. The unit can be conveniently 
moved from one container to another. 
 

 
 
 

 

 

 

Unpacking 

 

When unpacking the mixer, check carefully for 
damage that may have occurred during transit. Check 
for missing parts.

 

General Safety Information 

 

Warning: These mixers are intended for specific 

functions. Please follow all instructions to 
insure safe and proper use. 

 

(1)  Be certain that all mounting hardware and the coupling 

and propeller set screws are properly tightened prior to 
operation. 

 
(2)  Screw adapter into 2” bung opening in drum head. Be 

certain propeller is not touching side or bottom of drum. 

 
(3)  Series E & H Mixers are intended for use on steel drums. 

 
(4)  Perform electrical connections and wiring in accordance 

with the electrical area requirements and local electrical 
codes. 

 
(5)  Do not attempt to adjust mixer when mixer is operating, 

this could result in personal injury or damage to the tank 
and mixer. 

 
(6)  Always wear required safety equipment including eye 

protection when observing mixer performance or when 
adding materials to a tank while the mixer is operating. 

 
 

Assembly Instructions 

Models E & H Mixers 

 

(1)

 

Bolt motor to bung adapter using enclosed hardware. 

 
(2)  Attach coupling to motor shaft using setscrews. Note, the 

end of the coupling with the two setscrews spaced closely 
together attach to the motor. 

 
(3)  Attach propeller to round end of mixer shaft. 

 
(4)  Insert end of shaft with flat into coupling and tighten 

setscrews. 

 
(5)  Recheck all hardware for proper tightening. 

 
(6)  Attach to tank by threading into 2” bung opening. 
 

295 DeKalb Pike 
North Wales, PA 19454 
Tel: 215-699-8700 
Fax: 215-699-0370 
Toll Free Fax: 1-800-255-4017 

MODEL SERIES“E” 

MODEL SERIES“H” 

Reviews: