background image

Copyright © 2015 Draper Inc.  Form Revelation220V_Inst15  Printed in U.S.A.

Continued on page 2

Formula to find m 

(mounting point is back edge of rough cut 

farthest away from projection screen).

y = 15" + CL 

z = TD – y 

m = z + 8"

 

where: 

CL = centerline of lens to bottom feet

 

 

TD = throw distance

 

 

Accuracy: ± 6"

= CL

m

y

z

Installation/Operating Instructions

220 V Revelation Video Projector Mount by Draper

These Installation/Operating Instructions are available in the official language 
of the country where you purchase the product. Please contact your 
distributor to request a copy.
Vous pourriez demander les instructions d’installation et d’opération traduises 
dans la langue officielle du pays ou vous achetez le produit. Veuillez 
demander à votre distributeur.
Die Gebrauchsanweisung für Installation und Konstruktion sind in der 
offiziellen Sprache des Landes, indem Sie das Produkt gekauft haben, 
vorhanden. Fragen Sie die jeweilige Verkaufs-Abteilung.

As Soon As Revelation Arrives

1

 Open carton and inspect for damage.

2

 Locate the following parts:

  A. The unit itself
  B. Controls

Planning

1

 Based on screen location and projector specifications, determine proper  

  position for projector installation. 

(First see "Choose a projector based  

  on its light path" on page 3. Then read "Where to install the 
  Revelation" below.)

2

 Confirm that there is at least 458mm available above the ceiling for Model  

  B or 347mm for Model A, if Environmental Airspace Housing is used. If no  
  Environmental Airspace Housing, the minimum clearance is 331mm for  
  both models.

3

 Arrange to provide service access to electrical control box and  

  Environmental Airspace Housing.

4

 If connecting duct work to the Environmental Airspace Housing, plan for  

  position and length of duct work. 

(See guidelines under "Installing the  

  Environmental Airspace Housing Kit" on page 6.)

Caution

1

 Read instructions completely before proceeding.

2

 Follow instructions carefully. Installation contrary to instructions  

  invalidates warranty.

3

 Take great care when handling both first surface mirrors. They will  

  usually come covered with a protective film. Remove this film after  

  installation and prior to projecting images. If cleaning is necessary, do  

  so very lightly with glass cleaner and a soft, lint free cloth.

4

 Do not obstruct operation of door with fingers or any object. Serious  

  injury or damage could result.

5

 The Revelation is not designed to act as a structural support of ceiling  

  framing. However, the trim frame is designed to support ceiling T-grid,  

  tiles and drywall. 

Equipment should not be allowed to rest on door  

  at any time.

6

 Entire bottom of unit must be unobstructed to permit proper operation.  

  Sufficient clearance (432mm minimum) must be allowed below door.

7

 A minimum clearance of 458mm is required above ceiling level for  

  model B or 347mm for Model A, if Environmental Airspace Housing is  

  used. If no Environmental Airspace Housing, the minimum clearance is  

  331mm for both models.

8

 Unit must be installed level (use a carpenter’s level).

9

 Unit operates on 220 V a.c. 60 hz. current.

10 

Please Note: The Revelation is not compatible with lenses that have a  

  throw distance of less than 1.5:1.

Note:

 

Unit has been thoroughly inspected and tested at factory and found 

to be operating properly prior to shipment.

Metric Conversion
1 inch = 25.4 mm
1 inch = 2.54 cm

 

 

 

 

Where to install the Revelation

To determine where to mount the Revelation, you need to know the following:

1

 The projector manufacturer’s recommended throw distance (TD). Typically, 

  a minimum and maximum range is provided per screen size. Select a 
  throw distance that is 6" greater than the minimum and 6" less than the  
  maximum stated. We recommend the average of the two numbers. For  
  example, if the range given is 228" max. and 142½" min., then use a  
  number between 222" and 148½". We recommend using the average of  
  185¼" as the TD.

2

 The distance from the center line of the lens to the bottom of the projector’s  

  feet (CL). To find the mounting point (m = back edge of the rough cut) use  
  the following formula:
  y = 15" + CL 

z = TD – y 

m = z + 8"

Remember:

CL = 

Distance from center line of lens to bottom of projectors feet.

TD = 

Manufacturer’s horizontal throw distance for the selected screen size.

m = 

Calculated mounting point (mounting point is back edge of rough cut as 

measured from screen surface.)

As an example, if you are using a projector with recommended throw distance 
(TD) of 185¼" for a 100" diagonal image, and its CL dimension is 4", calculate 
the mounting point as follows:
  y = 15" + CL 

z = TD – y 

m = z + 8"

  y = 15" + 4" 

z = 185¼" – 19" 

m = 166¼" + 8"

  y = 19" 

z = 166¼" 

m = 174¼"

In the example above, the distance from the screen to the back edge of the 
rough cut would be 174¼". (Formula has a ± 6" accuracy).

Hanging Unit

The Revelation may be installed in a variety of ways. Typically, it is recessed 
above the ceiling and supported by six (6) 

3

/

8

" threaded mounting rods. The 

bottom of the main pan should be recessed approximately 76mm above 
the finished ceiling. The threaded rods should pass through mounting holes 
supplied in each corner and secured by nuts above and below. The unit 
should then be guy wired or blocked to prevent swinging.
All installations should observe the following guidelines:

1

 Installer must ensure that all fasteners and supports are of adequate  

  strength to securely support Revelation and projector.

2

 Fastening methods must be suitable for mounting surface, and securely  

  anchored so that vibration or abusive pulling on unit will not weaken  
 installation.

3

 Unit should be level, with weight shared more or less equally by all six  

  threaded mounting rods. 

Please Note: The Revelation is not compatible with lenses that have a 

throw distance of less than 1.5:1.

US Patent No. 

6,379,012

Summary of Contents for Revelation

Page 1: ...earance of 458mm is required above ceiling level for model B or 347mm for Model A if Environmental Airspace Housing is used If no Environmental Airspace Housing the minimum clearance is 331mm for both models 8 Unit must be installed level use a carpenter s level 9 Unit operates on 220 V a c 60 hz current 10 Please Note The Revelation is not compatible with lenses that have a throw distance of less...

Page 2: ...it must be unobstructed after installation 432mm minimum clearance is required below the door 5 Access should be provided to electrical control box in case service is required 6 Do not use unit to support adjacent light fixtures etc 7 Do not complete the ceiling below unit until electrical connections have been completed and unit has been operated successfully 8 We recommend that safety cables be ...

Page 3: ...ceiling By using the built in adjustment features of the Revelation you should be able to bring the top of the image below the ceiling Adjusting the ceiling closure door may introduce a keystone effect to the image If your projector has a keystone correction feature you may be able to compensate for keystoning Light Path C Single lens projectors with light path geometry C will work with the Reve l...

Page 4: ... Distance approx 432mm approx 432mm Travel Time 9 sec 9 sec Net Weight 39 kg 41 kg Shipping Weight 98 kg 100 kg Projector Space HWL To fit within parameters of inner pan 346mm is overall height of Revelation with Environmental Airspace Housing 330mm WITHOUT Environmental Airspace Housing 6 Mounting holes 9 525mm 3 8 dia Electrical hook up Lens and mirror centerline 462mm Projector 4 4 972 mm 946 m...

Page 5: ...www draperinc com 765 987 7999 YW PCB 1 220 VAC SUPPLY PROJECTOR OUTLET Dashed wiring by Electrician GND N 50 60 HZ L1 14 AWG 14 AWG RD BE YW GN 14 AWG YW GN RD BE F3 CB1B 8 RD 10 9 RD RD RD BK 6 7 4 5 3 2 1 F1 F2 YW YW C2 BK RD BE YW D1 RD DOWN ALL WIRES 18 AWG UNLESS OTHERWISE SPECIFIED BE BK 10 9 8 7 6 5 4 3 2 1 CB1A RD BE BE BE C1 BK RD BE BE BE WH DOWN LIMIT SW UP LIMIT SW RD RD BE BE BE WH B...

Page 6: ...ssive heat buildup inside the unit Keep duct work length as short as possible Recommended maximum total duct length is 914 cm input plus exhaust Keep the input to exhaust length ratio balanced and as small as possible to prevent air from being pushed into or drawn out of the room FIGURE 1 DIAGRAM 1 FIGURE 2 ENVIRONMENTAL AIRSPACE HOUSING INSTALLATION PART LIST ITEM DESCRIPTION QTY 1 INNER ENVIRONM...

Page 7: ...r of the unit Service and maintenance is made simpler due to the accessibility provided by this unique Environmental Airspace Housing design Each Environmental Airspace Housing also features a ventilation system designed to maintain a suitable operating environment for your projector An integrated current sensor in the Revelation circuitry turns on the fans anytime the projector is operating and c...

Page 8: ...ER by rotating it into the limit switch until the limit switch clicks and secure the lever onto the shaft using the 10 32 screw 4 and lock washer 5 supplied with the lever Be sure that the screw on the lever is tightened so that the lever does not twist on the shaft 8 After the VIC 12 7 is installed with the screen run the wiring to the Revelation using the cord strain relief 6 and connect to TB1 ...