07-01568B 05-29 Copyright 2007 Dri-Eaz Products, Inc. 1
Owner’s Manual –
Dri-Eaz Jet CXV TurboDryer
®
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA USA 98233
Fax: (360) 757-7950
Phone US: (360) 757-7776
www.dri-eaz.com
The Jet CXV is a high-powered airmover for the speed-drying of building structures and
contents. It is designed for maximum airflow with minimal amp draw, as well as versatility, durability and ease of use.
Read And Save These Instructions
Read and understand manual before operating.
ELECTRIC SHOCK HAZARD
WARNING! Unit must be grounded.
•
Use indoors only.
•
Do not operate in standing water.
•
If motor or wiring gets wet, allow to dry completely
before using.
•
Clean with compressed air or vacuum or wipe with a
damp cloth. Do not use hose or pressure washer.
•
To reduce the risk of fire or electric shock, do not use
this airmover with any solid-state speed control
device.
•
Insert 3-prong plug on power cord only into outlet with
Ground Fault Circuit Interrupting device.
•
Do not use adaptor.
•
Never cut off third prong.
•
Do not use an extension cord.
FIRE HAZARD
•
Keep air intakes and grills clear of obstructions and
dirt. Reduced airflow can cause motor to overheat.
Keep away from draperies or other material that could
block air intakes.
•
Keep away from open flames and heat sources.
•
Do not use or store where flammable vapors such as
from gasoline, solvents or thinners may be present.
SAFETY INSTRUCTIONS
WARNING! Unplug unit before opening housing for
cleaning or servicing
.
•
Always operate the unit on a stable, level surface.
•
Turn off unit. Unplug unit before lifting or moving. The
powerful airflow can make the unit difficult to control.
•
Inspect the power cord before use. If cord is
damaged, do not use. Replace with a cord of the
same type and amperage rating. Protect cord from
damage by turning off unit before unplugging. Always
grasp the plug (not pulling on the cord) to unplug.
•
The unit is designed to operate on a 115V/60 Hz
electrical connection. Make sure that the electrical
outlet is grounded.
•
Handle the unit carefully. Do not drop, throw, or place
on unstable surface where it could fall. Rough
treatment can damage the unit, and may create a
hazardous condition or void the warranty.
•
Keep children away from unit. Be sure unit is
inaccessible to children when it is not attended.
INTRODUCTION
The Jet CXV TurboDryer is a high-powered airmover for speed
drying of building structures and contents. It is designed for
use in commercial carpet or hard surface floor cleaning or
water damage restoration, offering maximum airflow with
minimal amp draw.
THE JET CXV TURBODRYER FEATURES:
•
Two protective grills; front grill with focused vanes for
channeling high-velocity air
•
.25 HP motor
•
Three-speed switch – 1.5, 2.0 and 3.0 amps
•
GFCI outlet for connecting up to 3 units (9 amps max.)
•
Stackable for storage and transportation
•
Designed for use with the Unimover hand truck to transport
multiple units