background image

Installation guide

ENGLISH 

DucoBox Energy Premium

Step by step 

instructions

duco.tv

L1315004-installatiehandleiding-DucoBox-Energy-Premium-(en)-DRUK

installation-guide-DucoBox-Energy-Premium-(en)

L1315004 (Revision H | 10.02.2020)

Summary of Contents for DucoBox Energy 325 Series

Page 1: ...Installation guide ENGLISH DucoBox Energy Premium Step by step instructions duco tv L1315004 Revision H 10 02 2020 ...

Page 2: ...rical system 17 08 A Pairing components 17 08 B Removing replacing components 18 08 C Tips 18 09 Air side calibration 19 09 A Pre setting vents 19 09 B Calibrating flow rates 20 09 C Verification 21 10 Display menu 22 10 A Display overview and operation 22 10 B Settings for the occupant 23 10 C Advanced settings 24 10 D Menu structure 26 11 Passive House 27 12 Maintenance service 27 13 Warranty 27...

Page 3: ...coBox Energy Premium 325 1ZS 325 460 under the 70 rule applicable in the Netherlands no imbalance no 0000 4358 0000 4359 DucoBox Energy Premium 325 1ZH imbalance heater yes 0000 4360 0000 4361 DucoBox Energy Premium 325 460 2ZS yes imbalance no 0000 4362 0000 4363 DucoBox Energy Premium 325 460 2ZH imbalance heater yes 0000 4364 0000 4365 DucoBox Energy Premium 400 1ZS 400 no imbalance no 0000 436...

Page 4: ...t at very low outdoor temperatures and enable it to operate cor rectly 1 Frost protection without a preheating element The supply flow rate is slowed down gradually such that more warm air passes across the heat exchanger This prevents the heat exchanger from freezing up If the imbalance is insufficient to prevent it from freezing up then the unit will be temporarily switched off 2 Frost protectio...

Page 5: ...t be copied neither shown to third party externally without written permission Drawing Number Volume Coat Surf Weight Outline A1003315 Format A2 Production Number Mat Draftsman MVR Tol Scale 0 100 DucoBox Energy Left Unit Date 31 Oct 17 148 112 40 957 274 740 305 122 584 152 275 190 160 Iteration Rev Date Name Description 31 Oct 17 Status Date Status A1003315 mm dm m kg m mm Handelsstraat 19 8630 ...

Page 6: ...y consumption AEC in kW for temperate climate 6 7 6 1 4 9 3 1 Annual heating savings AHS in kWh of primary energy a for temperate climate 45 4 45 6 46 0 46 7 DucoBox Energy Premium 400 DucoBox Energy Premium 400 DucoBox Energy Premium 400 DucoBox Energy Premium 400 Specific energy consumption SEC in kWh m a for a temperate climate 37 4 38 3 40 0 43 0 SEC class A A A A Type description VE Bidirecti...

Page 7: ...nect and commission the DucoBox Energy Premi um as set out in this manual Keep the manual close to your unit Maintenance instructions must be followed closely in order to avoid damage and or wear It is recommended that a maintenance contract be taken out to ensure the unit is regularly inspected and cleaned The device must be fitted in a touch sa fe manner This means among other things that under ...

Page 8: ...tatus 1 2 3 4 5 11 9 10 8 6 7 Iteration Rev Date Name Description 02 Nov 17 Status Date Status A1003315 mm dm m kg m mm Handelsstraat 19 8630 VEURNE tel 0032 58 330033 fax 0032 58 330044 email info duco eu www duco eu This drawing is property of Vero Duco NV and can not be copied neither shown to third party externally without written permission Drawing Number Volume Coat Surf Weight Outline A1003...

Page 9: ...ou have the op tion of allowing the Duco ventilation systems to commu nicate via ModBus and or ethernet ModBus integration enables them to be linked to a building management system Linking the Duco Ventilation App A Wi Fi router can be connected to the ethernet port on the Communication Print in order to link the Duco Venti lation App to the DucoBox Energy Premium The app can then be paired with t...

Page 10: ...nnections on the optional Communi cation Print see page 9 05 A Cabling diagram Use a screwdriver to press the lips in at the position shown and slide the cover forwards by around 1 cm 1 16 Jan 18 Status Date Status Lift the cover off the unit 2 Cut one or more or the specified pieces away from the housing to connect cables 3 05 B Connecting cables to the PCB RF 24 VDC 24 VDC A B GND B A GND POWER ...

Page 11: ... m free field less through obstacles Maximum number of components Up to 25 wireless components in a single system 05 D Wired cabled communication Wired components can be daisy chained recommended This means that a separate cable will not be required for each component A single central power supply can be used The cable required is a 0 75 mm data cable We strongly advise using a shielded cable This...

Page 12: ... seal off unused connection openings Take care to ensure that the air inlet is accessible for any cleaning that may be required A smaller cross sectional area bore can actually have a major detrimental impact on system performance Duco advises you to fit a minimum of 40 cm length of straight ducting before diverting the air flow on the intake side of the supply EHA SUP1 SUP2 ETA ODA 64 mm 0000 437...

Page 13: ...is hanging level when doing so Ensure at the same time that the screws and plugs are suitable for the substrate and the weight of the unit 47 kg screws and plugs not included in the supply 3 Iteration Rev Date Name Description 22 Nov 17 Status Date Status MONTAGE_MUUR mm dm m kg m mm Handelsstraat 19 8630 VEURNE tel 0032 58 330033 fax 0032 58 330044 email info duco eu www duco eu This drawing is p...

Page 14: ...TAGE_MUUR Format A0 Production Number Mat Draftsman Tol Scale 0 300 Date 23 Aug 17 Slide the cardboard packaging off the unit 1 Fit the optional mounting plinth in accordance with the manual supplied with it and ensure that it is positioned on a solid flat surface 2 Iteration Rev Date Name Description 22 Nov 17 Status Date Status MONTAGE_MUUR mm dm m kg m mm Handelsstraat 19 8630 VEURNE tel 0032 5...

Page 15: ... when fitting vents Take care to ensure that the supply and exhaust vents are a minimum of 1 5 m van apart so they cannot come into contact It is preferable not to fit a vent right next to a wall in order to prevent soiling In order to cut down resistance we recommend using 125 mm dia vents only Maximum exhaust flow rate per vent 75 m h Maximum supply flow rate per vent 50 m h Air ducts to HOUSE A...

Page 16: ...ox Energy Premium Electrical system see page 17 DucoBox Energy Premium air side calibration see page 19 A timer program will need to be set if there are no CO2 and or humidity sensors fitted in the system see page 23 Optional changing settings The factory settings will suffice in most cases However it is possible to configure settings such as the Bypass and comfort temperature to suit the occupant...

Page 17: ...remium without a 2 zone system 1Z types all components DucoBox Energy Premium with a 2 zone system 2Z types components in wet rooms only bathroom toilet kitchen laundry etc Short tap on a random key on all components to be paired The LED on the com ponent will start flashing green once it has been paired correctly The number of paired components will be shown on the display menu Confirm by pressin...

Page 18: ... will take on all settings connections in the network 1x NEW 3 Deactivate Installer mode by pressing the 4 buttons on a paired control simultaneously or using the palm of your hand on a control featuring touch buttons The LED will turn white 08 C Tips The network can be wiped or a full reset of the DucoBox Energy Premium can be carried out in the event of any problems To do this refer to the follo...

Page 19: ...mended for supply vents in order to prevent excessive noise from being genera ted For this reason it is recommended that the flow be split between different vents for higher flow rates SITUATION 1 One vent per zone SITUATION 2 Multiple vents per zone with equal flow rates SITUATION 3 Multiple vents per zone with different flow rates Set all vents to the fully open position regardless of the desire...

Page 20: ...each zone if asked to do so 3 In the Adjust the supply vents step select the duct with the highest flow rate and resistance and using a pressure compensated air flow meter measure the flow rate at this vent If the flow rate is too high or too low you can adjust it using the arrow keys on the DucoBox Energy Premium Depending on the user controller version this can also be done by pressing the lower...

Page 21: ...ification The calibrated flow rates can be checked at the various vents once adjustment and calibration have been completed Do this by going into advanced mode see page 24 and select CALIBRATION VERIFY HIGH LEVEL The DucoBox Energy Premium ventilate for 30 min at its calibrated ventilation setting ...

Page 22: ...n has been completed The following main screen will be visible after that Operation The display on the DucoBox Energy Premium has 3 buttons up down and enter The arrow keys can be used to scroll through the menu If the display has not been used in the normal operating mode it will be deactivated after 1 minute Press any button at random on the display in order to reactivate it Press any button at ...

Page 23: ... following method 10 B Settings for the occupant The following settings can be adjusted by the occupant Adjusting the timer program 1 Go to SETTINGS PROGRAM 2 Select the desired zone if it is a 2 zone system 3 Select the Mon Fri Sat Sun or Mon Sun mode Mon Fri Sat Sun is standard 4 Select the desired period in the week 5 Select ADD to insert a new time point up to 8 into the program 6 Set the desi...

Page 24: ...oor air This relatively cooler outdoor air entering the house will be used to reduce the temperature in the house as far as possible down to the desired temperature The standard setting for automatic bypass operation is activa ted but it can also be set manually Automatic operation recommended The bypass will gradually open if the temperature in the house rises too high and the outdoor temperature...

Page 25: ... advises against changing the standard settings Frost protection settings SETTINGS FROST PROTECTION STATUS for informa tion NORMAL frost protection on standby ACTIVE frost protection in operation HEATER Only if the unit is fitted with a heating element ALLOW use heater to heat air REFUSE do not use heater PASSIVE HOUSE For DucoBox Energy Premium 325 with heating element only ON deactivate imbalanc...

Page 26: ...ed values for Humidity Boxsensor SOFTWARE VERSION for information In any communication with Duco you may be asked to state the software version of your DucoBox Energy Premium Please keep this number to hand for any communication SERVICE CODE This code will enable the Duco service team to read out the composition of your ventilation system and its paired components SETTINGS COMFORT TEMPERATURE The ...

Page 27: ...Energy Premium to a separate fuse NB ensure there is sufficient natural ventilation e g open win dows whenever the unit is switched off Take account of local legislation as well in all cases 12 Maintenance service Please refer to the maintenance instructions at www duco eu and view the videos on duco tv for more information For service problems as a user Please contact your installer Keep the seri...

Page 28: ...Installed by L1315004 Document last modified on 10 02 2020 revision H ...