This manual is subject to modification without advice
MADE IN ITALY
THE INSTALLER HAS TO FOLLOW REGULATIONS. INTERVENTIONS MADE BY NOT AUTHORIZED STAFF CAN DAMAGE THE DEVICE.
THE PRODUCER IS NOT RESPONSIBLE IN CASE OF IMPROPER USE OR WRONG INSTALLATION.
DO NOT INSTALL THE RECEIVER IN DUMP PLACES OR EXPOSED AT HIGH/LOW TEMPERATURES OR INCLEMENCY OF THE WEATHER.
FOR MORE SAFETY, INSTALL THE RECEIVER IN A PLACE PROTECTED BY AN ALARM DETECTOR.
RX2AP
is a receiver that can store up to 10 radio codes (auto-learning) combined to 2 independent outputs (5 radio codes each): the outputs are dry-contact relay type.
It is possible to learn the radio codes of sensors, remote controls or special transmitters (TSR) for control panels.
This device allow a simple interface between wired control panels and wireless sensors or remote controls.
INDEX
1.
RESET
The following procedure bring back the receiver to factory settings. It is necessary to run the reset before start programming and use the device.
1.
Remove power to the receiver (wait about 1 minute the circuit discharges)
2.
Hold down the
P
button while powering the receiver
3.
After about 5 seconds the receiver emits three quick “beep” followed by one long one
4.
Release the
P
button. The reset is complete.
RX2AP
TWO OUTPUTS RADIO RECEIVER
[AN]
Installation and use manual
15.10-M:4.1-H:x.x-F:F9D0
Radio Zone A-1
RELAY A
Radio Zone A-2
Radio Zone A-3
Radio Zone A-4
Radio Zone A-5
Radio Zone B-1
RELAY B
Radio Zone B-2
Radio Zone B-3
Radio Zone B-4
Radio Zone B-5
Matching scheme of Radio
Zones with Relay Outputs: