 is a receiver that can store up to 10 radio codes (auto-learning) combined to 2 independent outputs (5 radio codes each): the outputs are dry-contact relay type. 

It is possible to learn the radio codes of sensors, remote controls or special transmitters (TSR) for control panels. 
 
 
 
 
 
 
 
 
 
This device allow a simple interface between wired control panels and wireless sensors or remote controls. 
 
 
 

INDEX 

1.

 

RESET ................................................................................................................................................................................................................................................ 1

 

2.

 

TECHNICAL ........................................................................................................................................................................................................................................ 2

 

3.

 

LEARNING ......................................................................................................................................................................................................................................... 2

 

4.

 

“S REMOTE CONTROLS” MODE DIP1 = OFF | DIP3 = OFF | DIP4 = OFF.............................................................................................................................. 3

 

5.

 

“REMOTE CONTROLS” MODE DIP1 = OFF | DIP3 = OFF | DIP4 = ON ................................................................................................................................................. 3

 

6.

 

“LIGHT TIMER” MODE DIP1 = OFF | DIP3 = ON | DIP4 = OFF ............................................................................................................................................................ 4

 

7.

 

USE OF THE TSR TRANSMITTER DIP1 = OFF | DIP3 = OFF | DIP4 = OFF .............................................................................................................................................. 4 

 
 
 

1.

 

RESET 

The following procedure bring back the receiver to factory settings. It is necessary to run the reset before start programming and use the device. 

1.

 

Remove power to the receiver (wait about 1 minute the circuit discharges) 

2.

 

Hold down the 

P

 button while powering the receiver 

3.

 

After about 5 seconds the receiver emits three quick “beep” followed by one long one 

4.

 

Release the 

P

 button. The reset is complete. 

 
 
 

RX2AP 

 

TWO OUTPUTS RADIO RECEIVER 

 

[AN] 

Installation and use manual 

15.10-M:4.1-H:x.x-F:F9D0 

Radio Zone A-1 

RELAY A 

Radio Zone A-2

 

Radio Zone A-3

 

Radio Zone A-4

 

Radio Zone A-5

 

Radio Zone B-1

 

RELAY B 

Radio Zone B-2

 

Radio Zone B-3

 

Radio Zone B-4

 

Radio Zone B-5

 

Matching scheme of Radio 
Zones with Relay Outputs: 

Summary of Contents for RX2AP

Page 1: ...sors or remote controls INDEX 1 RESET 1 2 TECHNICAL 2 3 LEARNING 2 4 SENSORS REMOTE CONTROLS MODE DIP1 OFF DIP3 OFF DIP4 OFF 3 5 REMOTE CONTROLS MODE DIP1 OFF DIP3 OFF DIP4 ON 3 6 LIGHT TIMER MODE DIP1 OFF DIP3 ON DIP4 OFF 4 7 USE OF THE TSR TRANSMITTER DIP1 OFF DIP3 OFF DIP4 OFF 4 1 RESET The following procedure bring back the receiver to factory settings It is necessary to run the reset before s...

Page 2: ...ible to overwrite lights on OR 3 To go to the next Radio Zone press P As confirm the receiver emits as many beep as the Radio Zone number Radio Zone A 2 2 beep Radio Zone A 3 3 beep 1x BEEP 5x BEEP DIP1 OFF Normal working ON LEARNING pairing of radio devices DIP2 OFF Relay A Monostable ON Relay A Bistable DIP3 OFF Normal working ON LIGHT TIMER mode DIP4 OFF Sensors Remote controls mode or use with...

Page 3: ...learn the DSF smoke sensor hold down the TEST button for some seconds Read the manuals of each product for further information 4 SENSORS REMOTE CONTROLS MODE DIP1 OFF DIP3 OFF DIP4 OFF In this mode both sensors and remote controls work the remote controls must be stored only in Relay A zones Radio Zones A 1 A 5 Set the working mode of the Relay A for remote controls with DIP2 DIP2 ON RELAY A BI ST...

Page 4: ...e receiver can be paired with TSR transmitter for sirens to visualize from remote the alarm system status The TSR transmitters must be stored only in Relay A zones Radio Zones A 1 A 5 The remote controls must be stored only in Relay A zones Radio Zones A 1 A 5 The receiver works differently depending on DIP2 setting DIP2 ON BI STABLE The Relay A is activated when it is received the ARM code of a T...

Reviews: