background image

Dust Networks

SmartMesh

®

 IA-510

D2511 Manager Guide

Industrial

Summary of Contents for SmartMesh IA-510 D2511

Page 1: ...Dust Networks SmartMesh IA 510 D2511 Manager Guide Industrial...

Page 2: ...ical component in any life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectivene...

Page 3: ...es 2 SmartMesh Manager s Role 2 Manager Packing List 2 Manager Overview 3 10 100Base T Ethernet Interface 3 Serial 1 Interface 4 Serial 2 Interface 6 2 Specifications Detailed Radio Specifications 7 A...

Page 4: ...uter 14 Installing the Manager on the LAN 15 A Configuring Serial 1 Operation Configuring the Serial 1 Interface 17 Using Admin Toolset to Configure Serial 1 17 Using Linux Commands to Configure Seria...

Page 5: ...and instructions on configuring the serial port application function SmartMesh Manager XML API Guide provides information about manager s hierarchical tag based XML API SmartMesh CLI Commands Guide de...

Page 6: ...ABOUT THIS GUIDE iv SMARTMESH IA 510 D2511 MANAGER GUIDE Revision History Revision Date Description 040 0075 rev 1 8 5 2009 Final product release 040 0075 rev 2 11 18 2009 040 0075 rev 3 8 10 2010...

Page 7: ...orks that can be used for a wide variety of condition monitoring applications such as vibration monitoring HVAC monitoring at large commercial sites wind monitoring solar tracker monitoring and enviro...

Page 8: ...eliable They provide redundant self healing routing that approaches the reliability of a wired network Benefit You have the reliability of a wired network with the flexibility of wireless Manageable T...

Page 9: ...e the following information Power Green The Power LED is on when the 12 V power supply provided with the D2511 is connected and functioning properly Subscription Yellow Indicates that a client program...

Page 10: ...Channel is used to stream data and network events to the client program The API is fully documented in the SmartMesh IA 510 Manager XML API Guide Admin Toolset The D2511 manager provides a Web based...

Page 11: ...D SUB RS232 port See Appendix B for information on assembling an RJ45 to 9 pin D SUB adapter PPP The manager allows IP connection through the Serial 1 port using Point to Point Protocol PPP This conne...

Page 12: ...ion of the Serial 1 interface and for troubleshooting with the assistance of Dust Networks support Appendix A provides instructions on using the CLI to set the Serial 1 configuration Figure 5 9 pin D...

Page 13: ...itivity 92 5 dBm At 50 PER 25 C 90 dBm At 1 PER 25 C inferred from 50 PER measurement Output power EIRP PA enabled PA disabled 10 0 dBm dBm See Antenna Specifications Range PA enabled 25 C 50 RH 2 dBi...

Page 14: ...1 1 Amps DC and it is connected to positive and ground terminals of the connector However any DC supply with an output of 9 30 V at 0 5 Amps can be connected A 24 VAC supply can be connected to the tw...

Page 15: ...Mechanical Drawings CHAPTER 2 SPECIFICATIONS SMARTMESH IA 510 D2511 MANAGER GUIDE 9 Mechanical Drawings Figure 7 Dimensions of D2511 Manager...

Page 16: ...ntentional Radiators CE Compliance Declaration of Conformity We Dust Networks of 30695 Huntwood Ave Hayward CA 94544 USA declare under our sole responsibility that our products SmartMesh IA 510 D2511...

Page 17: ...Conditions CHAPTER 2 SPECIFICATIONS SMARTMESH IA 510 D2511 MANAGER GUIDE 11 Normal Operating Conditions Table 9 D2511 Normal Operating Conditions Parameter Min Typ Max Units Comments Operating tempera...

Page 18: ...CHAPTER 2 SPECIFICATIONS Normal Operating Conditions 12 SMARTMESH IA 510 D2511 MANAGER GUIDE...

Page 19: ...510 Evaluation Kit Guide Ports Used by the D2511 Manager The transmission control protocol TCP ports listed in Table 10 must be open to allow the Admin Toolset utilities to connect to the D2511 manag...

Page 20: ...talled To connect the manager directly to a computer A Use the Ethernet cross over cable to connect the manager to your computer B Connect the power cord to the manager and an AC outlet The Power ligh...

Page 21: ...he manager on the LAN you need to change the manager s default static IP address to a LAN IP address You can either configure the manager to use DHCP to obtain a LAN assigned IP address or assign a st...

Page 22: ...atic LAN IP address provided by your LAN administrator enter sudo ifswitch to static New Static IP Address H Verify that the manager s IP address has been changed by entering ifconfig Then manager s n...

Page 23: ...e is intended for local serial connections only Because no authentication is performed use it only in a trusted environment Using Admin Toolset to Configure Serial 1 To configure Serial 1 for PPP A Co...

Page 24: ...terfaces link F In the Interfaces Serial Port Settings area change the serial port settings if necessary If you are setting up a PPP connection enter the local and remote PPP IP addresses dNote By def...

Page 25: ...ol The command options are as follows device ttyS1 speed 4800 9600 19200 38400 57600 115200 or 230400 parity none even or odd stopbits 1 or 2 flow control on or off The following are sample commands s...

Page 26: ...APPENDIX A CONFIGURING SERIAL 1 OPERATION Configuring the Serial 1 Interface 20 SMARTMESH IA 510 D2511 MANAGER GUIDE...

Page 27: ...female RJ45 to female 9 pin D SUB The arrows indicate how to match up the RJ45 and 9 pin D SUB connector pins described in Table 11 Table 11 Matching Up RJ45 and 9 pin D SUB Connector Pins Manager PC...

Page 28: ...22 SMARTMESH IA 510 D2511 MANAGER GUIDE APPENDIX B ASSEMBLING A 9 PIN D SUB ADAPTER FOR SERIAL 1...

Page 29: ...common join key Access control list cleared Log files cleared Mote list cleared To restore the manager s factory default settings A Insert a jumbo paper clip into the Mode hole and gently press and h...

Page 30: ...ter the default manager IP address 192 168 99 100 https 192 168 99 100 c If navigation to the site is blocked due to a certificate error click to continue on to the Web site the Web site is safe d In...

Reviews: