Hurricane SCR Battery Chargers Series 

 

 

 

Operating Manual 

 

 

 
 

 

 
 
 

 

 

 

 

Attention: Carefully read the operating manual before using the battery charger.

 

 

 
 

Edition: Oct. 15, 2004

12 volt – 12 amp 
(for battery sweeper) 

Code: 19473  

 
24 volt – 12 amp 

(for Hurricane 500 XTT 
and Hurricane 600 XTT) 

Code: 19465 

24 volt – 25 amp  
(for Hurricane 700 XTT 

and Hurricane 850 XTT 

Code: 19509 

 

36 volt – 22 amp  
(for Hurricane 900 XTT 
and Hurricane 250 XT) 

Code: 19468 

Summary of Contents for Hurricane SCR Battery Chargers Series

Page 1: ...ting Manual Attention Carefully read the operating manual before using the battery charger Edition Oct 15 2004 12 volt 12 amp for battery sweeper Code 19473 24 volt 12 amp for Hurricane 500 XTT and Hurricane 600 XTT Code 19465 24 volt 25 amp for Hurricane 700 XTT and Hurricane 850 XTT Code 19509 36 volt 22 amp for Hurricane 900 XTT and Hurricane 250 XT Code 19468 ...

Page 2: ...indicates power into unit and that fuse is OK 3 Fast Acting Fuse blows in the event of a failure 4 Amp Meter indicates charging current 5 Red Control Indicator when lit it indicates start of charge cycle 6 Yellow Control Indicator flashes to indicate 80 charge level is reached 7 Green Control Indicator when lit it indicates that the charge cycle is completed 1 1 2 2 3 3 4 4 7 6 5 7 6 5 CBN1 CBN2 ...

Page 3: ...he affected parts with fresh water and consult a doctor if necessary Check fluid level before charging to make sure plates are covered Top up the water level only after charging Refill with distilled water only Do not use tap water Keep terminals and battery casing clean OPERATION Put the main switch 1 in the OFF position and connect the AC cord to the power supply Connect the battery charger to t...

Page 4: ... date of manufacture D mains voltage E input current F fuse rating G output voltage H output current I charging curve L range of battery sizes possible OTHER TECHNICAL DATA Storage Temperature Range 40 to 50 degrees Celcius Relative Humidity Range 0 80 Operating Temperature Range 10 to 50 degrees Celcius REPAIRS Repairs must only be carried out by qualified personel Use only original equipment man...

Page 5: ...20 X X 19426 Fuse 15a F 6 3 x 32 19427 Fuse 8a F 6 3 x 32 X X 19428 Fuse 6 3a F 5 x 20 X 19429 Card CBNPO15A assembled 12V 12A Wa X 19430 Card CBNPO15A assembled 24V 12A Wa X 19431 Card 15XX 3N 12 24V Wa X 19432 Card 15XX 3N 36V Wa X 19433 Card CBNTLA 12V Wa X X 19434 Card CBNTLA 24V Wa X 19435 Card CBNTLA 36V Wa X X 19436 AC power cord with plug 3 x 18 awg X X 19437 AC power cord with plug 3 x 14...