Summary of Contents for Pro-X CSADX3200

Page 1: ...OWNERS MANUAL MODELS DX3200 CSADX3200 225 South Cardova Avenue Le Center Minnesota 56057 ...

Page 2: ...s B1 Unit Capabilities B1 Where is Everything Located B2 PREPARING THE UNIT C1 Unpacking the unit C1 Oil Requirements C1 Fuel Requirements C1 Battery Installation C1 BASIC OPERATION D l Initial Start Up D l Starting and Stopping Dl Connecting the Loads D2 OPERATOR MAINTENANCE El Engine Care El Generator Care E l Unit Cleaning E l Things to Check before you call for Service E2 Wiring Diagram E3 PRO...

Page 3: ...ated ABC by NFPA are appropriate E Store fuel only in an approved container and on ly in a well ventilated area 3 DEADLY EXHAUST GAS Exhaust fumes from any gasoline engine contain carbon monoxide an odor less and deadly gas that must be mixed with fresh air A Operate only in well ventilated areas B Never operate indoors C Never operate the unit in such a way as to allow exhaust gases to seep back ...

Page 4: ... 1 1 1 5HP 5HP FA210 FA210 See Engine For Type 3 4 GAL 3 4 GAL 0 75 glhr 0 75 glhr Recoil Switch on Engine Shroud Standard Standard Muffler with Spark Arrestor 99 LBS 99 LBS 24x15 14 24x15x14 Unleaded Gasoline SAE30 SC Class See engine manual for additional info 64 US qt 64 US qt the engine and the generator Small compartments will also develop hot spots where there is very little air flow and may...

Page 5: ...4 5 22 TO 32 9 TO 18 7 TO 12 113 5 2 26 TO 35 10 TO 21 8 TO 17 112 7 2 NOT MADE 14 TO 29 11 TO 18 1 13 0 NOTMADE26TO52 20TO33 WHERE IS EV L The figures given above are for average loadssuch as a blower or fan If the electric motor is connected to a hard starting load such as an air compressor it will require more starting current If it is connected to a light load or no load such as a power saw it...

Page 6: ...d 1 Lubrication Before starting the engine fill the crank case to the proper level with a good quality oil The recommendedgrade of oil and quantity of oil required is listed in both the engine operators manual and in the specifications section page B1 of this manual The importance of using the correct oil and keep ing the crankcase full cannot be overemphasized Engine failures resulting from inade...

Page 7: ... to gasoline in a storage container 1 Remove the remaining fuel from the fuel tank 2 Start the engine and allow it to run until all the fuel in the carburetor and the fuel lines has been used up and the engine stops 3 While the engine is warm drain oil and refill with fresh oil 4 Remove the spark plug pour approximately 112 ounce 15 cc of engine oil into the cylinder and crank slowly to distribute...

Page 8: ...r rod into the ground close to the engine generator set The pipe must penetrate moist earth Connect an approved ground clamp to the pipe Run a no 10Awg wire from clamp to the generator ground lug or the bat tery negative terminal Do not connect to a water pipe or to a ground used by a radio system 3 Connecting the Battery Enclosed with your new generator set you will find a 12V DC connector lead w...

Page 9: ...vent Poor spark will occur if ter minal does not fit firmly on spark plug If this hap pens re form the terminal to fit firmly on spark plug tip GENERATOR CARE Proper care and maintenance of the generator is necessary to insure a long trouble free life 1 Exercising The Generator The generator should be operated every three to four weeks It should be op erated for a period of time sufficient to warm...

Page 10: ... battery Defective start switch Voltage too low Check for proper engine speed Generator overloaded Defective rectifier Defective Armature Defective Field Coil Voltage too high Engine speed is too high Problem Possible Causes Generator Overloaded overheating Insufficient ventilation No output voltage Short in load disconnect No residual magnetisim in generator Defective armature Defective field coi...

Page 11: ...ION ClRCUlT CAYS I I I RECTIFIER SHUNT FIELD COILS POWER CIRCUIT d tluutiI c i l n FULL POWER WINDING SLIP RINGS YRUSHES BATTERY CHARGE BAnERY CHARGE ECTIFIER CIRCUIT BOOST 7 OUTPUT mnn AC BATTERY CHARGING AUTO RESET WINDING CIRCUIT BREAKER 120 VOLT 4 25 AMP 120 VOLT CIRCUIT BREAKER 9 9 CIRCUIT BREAKER A A I NEUTRAL N i NOT USED ...