System Description

The WaterCopPRO System is designed to detect leaks in 

your plumbing system at predetermined locations, and 

automatically shut off the water supply to help effectively 

reduce the chances of major water damage associated 

with a leak.

System Components

Brass Valve:

 Full port, ANSI NSF 372 approved, lead-free, 

brass, 125 psi cold water, designed for placement on 

incoming water main.

WaterCopPRO Actuator:

 Polycarbonate housing containing 

motor to drive valve, AC/DC power converter with 20’ cord, 

liquid crystal display with back light for sensor/trouble 

status, ambient temperature 35°F to 105°F, manual override, 

local open/close water control.

Flood Sensor:

 Wireless sensors are addressable and 

supervised for conditions such as water detection, actuator 

power loss, sensor short/open and low battery. Ten foot 

sensor cord allows optimal sensor placement. Flood sensors 

can support one or two sensor probes. Each WaterCopPRO 

actuator can support up to 45 wireless sensors.

Range Enhancing Repeater:

 Enhances transmission range 

of wireless sensors. Plugs into any standard wall outlet. 

Receives and re-transmits sensor signals from outlying 

sensors to the WaterCopPRO actuator.

Monitoring Station – Standard:

 LCD display with back light 

provides instant feedback of sensor alarm and trouble 

conditions as well as open/close status of water supply. On/

Off push button for local control of water supply. Audible 

alarm sounds when any sensor detects flooding. Internal 

mounting bracket mounts to standard wall boxes for 

aesthetics and cord management. AC/DC power converter 

with 20’ cord included.

Monitoring Station – Hardwired: 

Accommodates up to 8 

zones for WPSC hardwired flood sensors (sold separately).
The flood sensors are a battery powered device enabling 

it to be located  anywhere a leak is likely to occur, or 

where water might cause damage. The WaterCop requires 

household electrical power  (common 115   VAC, grounded 

outlet) and will not  operate during a power outage.

Summary of Contents for WaterCopPRO

Page 1: ...05 F manual override local open close water control Flood Sensor Wireless sensors are addressable and supervised for conditions such as water detection actuator power loss sensor short open and low battery Ten foot sensor cord allows optimal sensor placement Flood sensors can support one or two sensor probes Each WaterCopPRO actuator can support up to 45 wireless sensors Range Enhancing Repeater E...

Page 2: ...ardwired Sensors Ten foot white cord with single sensor PRO sensors are easily secured to floor using mounting holes Sensors provide the same feedback to monitoring station as the wireless WaterCopPRO sensors Use hardwired sensors for convenience or if conditions prevent wireless communication Sensors sold individually and can be wired with up to 200 of 22 24 AWG 2 conductor cord not included Gene...

Page 3: ... on the face of the unit WaterCopPRO Specifications Max working pressure 125 PSIG Ambient temperature 35 to 105 F Enclosure Polycarbonate NEMA 4 Voltage 12 VDC includes 120 VAC adaptor Current 1 3 Amps Valve Full Port ANSI NSF 372 approved Lead Free Brass NPT Valve seals RTFE Reinforced Teflon FCC Information This equipment has been tested and found to comply with the limits for a class B digital ...

Page 4: ...E TO ADD DEVICES SENSORS Press MODE twice DEVICE ADD on WaterCopPRO Actuator Press CLOSE DEVICE 1 ID Short probe on Sensor SENSOR 1 SHT Remove Short SENSOR 1 OK Press MODE Press CLOSE SENSOR 2 ID Repeat for all Sensors When finished Press MODE 2X to return to NORMAL MONITORING STATION Press MODE twice DEVICE ADD on WaterCopPRO Actuator Press CLOSE DEVICE 1 ID next device number ID on WaterCop Actu...

Page 5: ...uip Controls to inquire about additional sensors Once each sensor is powered and numbered you are ready to begin addressing the sensors to the WaterCopPRO actuator Programming Wireless Sensors Plug the WaterCopPRO actuator power supply into a nearby 115 VAC outlet As with all sensitive electric equipment the use of surge protection is highly recommended Depending upon the position of the valve the...

Page 6: ...e back of the sensor and install batteries in accordance with the and placement guide Reinstall back plate Follow suggestions found in the section titled Placement of Flood Sensors for recommendations where sensors should be placed Locate a wall near the area you choose to monitor Avoid high traffic areas where cord or sensor could be stepped on or kicked Mount transmitter at a convenient location...

Page 7: ...n nuts and sleeves to each tube end 9 Shift tube ends to install WaterCopPRO valve in line Verify that the transmitter and wire are clear of doors drawers sharp edges or other hazards that may cause damage Unplug the WaterCopPRO after the testing is complete The WaterCopPRO can now be installed into the plumbing system Prior to installation read all warnings and precautions carefully Installation ...

Page 8: ...rload the circuit supplying power As with all sensitive electric equipment the use of surge protection is highly recommended DynaQuip Controls 10 Harris Ind Pk St Clair MO 63077 800 545 3636 www watercop com 8 192261 rev C Warnings and Precautions WARNING The motorized drive unit case is not capable of supporting any loads Do not attempt to use the unit as a step This will cause damage to the unit...

Reviews: