Find this document and further product information on our website at www.epluse.com/ee210.

The EE210 sensor which is available for wall or duct mounting, with remote probe as well as an outdoor version, is designed for 

highly accurate measurement of humidity and temperature in demanding climate control applications. The EE210 incorporates a 

state of the art E+E humidity and temperature sensing element.

For use in special applications do not hesitate to contact E+E Elektronik or a local distributor.

GENERAL

• 

For accurate measurement it is essential that the temperature of the probe and mainly of the sensing head is same as the 

temperature of the air to measure. Avoid mounting the sensor in a way which creates temperature gradients along the probe. 

• 

The sensor and mainly the sensing head shall not be exposed to extreme mechanical stress. 

 

• 

The sensor must be operated with the filter cap on at all times. Do not touch the sensing element inside the sensing head. 

• 

While replacing the filter cap (because of pollution for instance) against an original spare one please take very good care to 

not touch the sensors. 

CAUTION

USB configuration adapter  

HA011066

Product configuration software  

EE-PCS 

(free download: www.epluse.com/ee210)

Radiation shield for EE210 Outdoor (Type T13) 

HA010501

Power supply adapter  

V03 

(see data sheet Accessories)

Protection cap for 12 mm probe 

HA010783

SCOPE OF SUPPLY

Model

EE210  

Wall mount / Outdoor 

(Type  T1 / T13)

EE210  

Duct mount  

(Type T2)

EE210  

with remote 

probe (Type T3)*

PE210  

Remote probe* for 

Type T3

Additionally for 

all EE210 with 

RS485 interface

EE210 according ordering guide

Cable gland

(2 pcs.)

Mounting materials

Mounting flange
Inspection certificate according 

to DIN EN 10204-3.1

Quick Guide -  

EE210 RS485 Setup

PE210 is not included in the Scope of Supply of the EE210 Type T3

ACCESSORIES

Summary of Contents for EE210

Page 1: ...or and mainly the sensing head shall not be exposed to extreme mechanical stress The sensor must be operated with the filter cap on at all times Do not touch the sensing element inside the sensing hea...

Page 2: ...10501 for Type T13 needs to be ordered separately Type T13 5 20 20 1 5 122 44 105 174 44 94 4 1 6 9 1 7 3 7 4 8 0 2 0 8 0 1 0 8 1 7 80 37 2 80 55 32 12 1 5 3 5 3 5 2 2 1 3 0 5 EE210 with cable gland U...

Page 3: ...t The replacement probe shall be installed as described above Important Make sure that the cable glands are closed tightly for both PE210 probe cable and for the power supply and outputs cable This is...

Page 4: ...y setup current output 0 20 mA corresponds to 10 50 C After switching from I to U voltage output 0 10 V corresponds to 10 50 C A change of the voltage output range for instance to 0 5 V can be made su...

Page 5: ...0 0x27 specific enthalpy kJ kg BTU lb 30042 0x29 frost point temperature C F INTEGER 16 bit read register Function code Register number1 Dec Register address2 Hex Parameter name Unit3 Scale4 30301 0x1...

Page 6: ...2 Register 2 Lo Byte 3 Register 1 Hi Byte 4 Register 1 Lo 41 C2 29 00 24 270019 TECHNICAL DATA Modification rights reserved Measured Values Relative Humidity RH Working range 0 100 RH RH accuracy1 inc...

Page 7: ...y max 40 mA with display max 40 mA 3 wire DC supply typ 33 mA with display max 44 mA AC supply typ 65 mArms with display max 84 mArms Digital interface DC supply typ 5 mA with display max 20 mA AC sup...

Page 8: ...nik Calibration and or adjustment can be performed in the E E Elektronik calibration laboratory For information on the E E capabilities in ISO or accredited calibration please see www eplusecal com Ca...

Page 9: ...to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates...

Reviews: