OK
Compliant with: EN 50379-1, EN 50379-2
Features
Combustion, Flue gas & Emissions analysis
Calculating of stack heat loss and efficiency
CO environment measurement
Measuring differential pressure
Draft measurement
Pressure measurement in the gas supply pipe
Store Smoke values, calculating mean value
Date: 7/08/14
Time: 10.10
Fuel: Natural gas
Altitude: 0 m
R.H. air: 50 %
O2 4.2
٪
CO2 9.3
٪
Ex. Air 20
٪
T flue 374.2 °F
T air 60.4 °F
ΔT 313.8 °F
Loss tot 8.6
٪
Eff. Tot 91.4
٪
CO 148 ppm
CO amb 0 ppm
Draft: 0.05 inH
2
O
Smoke: 3 1 2
Aver n. : 2
——————————————————————
——————————————————————
——————————————————————
——————————————————————
——————————————————————
7/08/14
10:00
Eff. tot
%
91.4
Loss tot
%
8.6
ΔT
°F
74.7
T air
°F
15.4
T flue
°F
190.1
Ex. Air
1.25
CO
2
%
9.3
O
2
%
4.2
Memory
Average analysis
7/08/14
10:00
Print
Report
Model
partial
Analysis
average
OK
Memory
1
7/08/14
10:00
Print
Report
Model
partial
Analysis
In average
F1
Memory
1
In case the automatic print mode is set then the average analysis printing start automatically.
Conversely, after the sampling of the third analysis, the average analysis is shown, so that it can be sent to the
printer as explained in the following.
OK
Memory
Save
7/08/14
10:00
OK
Memory
1
Mode
data logger
Samples
10
Interval
s
60
Automatically
saves the first
sample when the
set interval
expires, and so on
until the third
sample.
7/08/14
10:00
Eff. tot
%
91.4
Loss tot
%
8.6
ΔT
°F
74.7
T air
°F
15.4
T flue
°F
190.1
Ex. Air
1.25
CO
2
%
9.3
O
2
%
4.2
Combustion analysis
7/08/14
10:00
Eff. tot
%
91.4
Loss tot
%
8.6
ΔT
°F
74.7
T air
°F
15.4
T flue
°F
190.1
Ex. Air
1.25
CO
2
%
9.3
O
2
%
4.2
Combustion analysis
1
120
KEYBOARD FUNCTIONS
KEYS
FUNCTION
Activate the context keys shown on
the display
Enters the Memory menu
Enters the Print menu
Enters the Configuration menu
Previes the combustion analysis
Enters the measurements menu
Turns the instrument on/off
Quits the current screen
Selects and/or modifies
Confirms data
CONTEXT KEYS
CONTEXT KEY FUNCTION
ZERO the pressure sensor
Updates the measure
Saves the current measurement or
analysis in the memory location selected
from the ‘Select Memory’ menu
Starts the report ticket
Enters the Print menu
Stops the flue gas analysis
Enters the modify mode for the selected
parameter
Confirms the settings
Cancels the change/operation and
returns to the previous screen
Zooms the screen
Shows the details for the selected
parameter
‘Find’ function; starts a quick search for
the analysis to recall
OK
O
Esc
OK
Configuration
Fuel
7/08/14
10:00
Biogas
Propane-Air
Fuel oil
Diesel oil
Butane
L.P.G.
Propane
Natural gas
OK
7/08/14
10:00
Analysis
Operator
Information
Language
Instrument
Alarms
Diagnostic
Configuration
Restore
7/08/14
10:00
Fuel
O
2
reference
Autozero
Condensation
Measure units
Measures list
Configuration
Analysis
WARNING
F1: stop
Printing.
Please wait...
E Instruments respects the nature and the environment, therefore provides this quick user guide to
avoid any unwanted waste of paper.
However the complete manual for use and maintenance of the instrument is already available in
the USB stick (included),.
Respect your environment: think before printing the full manual on paper.
The magnets in the back of the instrument can damage credit
cards, hard drives, mechanical watches, pacemakers,
defibrillators and other devices proven sensitive to magnetic
fields.
It is recommended to keep the instrument at a distance of at
least 10” away from any of these devices.
402 Middletown Blvd, Suite 216, Langhorne, PA 19047 USA
Tel: (215) 750-1212; Fax: (215) 750-1399
info@E-Inst.com - www.E-Inst.com
To view different test measurements, use ' ' key to scroll through the various test measurement screens.
WARNING! - Before proceeding with the combustion analysis remember to set the proper fuel.
Xair
= Excess Air
Δ
T
= Differential Temperature (NET Temperature)
Tg
= Flue Gas Stack Temperature
Eff. tot
= Total Combustion Efficiency
Ta
= Ambient or Incoming Air Temperature
Loss tot
= Stack Losses
K000000000EJ 027995 010217
1500
COMPLETE MANUAL
ON USB FLASH DRIVE