background image

U s e r   M a n u a l

Summary of Contents for clinic

Page 1: ...U s e r M a n u a l ...

Page 2: ...ARKINGS ERROR MESSAGES STANDARDS SHOWROOM WARRANTY CONDITIONS CHANGING THE CARTRIDGE RETURNING USED CARTRIDGES SOFTWARE OPTIONS HAIR REMOVAL WITH THE PACKAGE CONTENTS PRECAUTIONS FOR USE GLOSSARY INFORMATION PROVIDED BY TOUCH SCREEN 4 8 12 14 18 44 46 32 40 38 48 50 52 53 54 55 ...

Page 3: ...essional quality pulsed light in the comfort of your home I have personally ensured that the utmost attention be paid to the implementation of each you will see that is an exceptional product I hope that you will be completely satisfied with your and that you will share your experience on our company s offi cial website at www e swin com Yours Sincerely Yves Vincent Brottier Creator of ...

Page 4: ...be used for professional purposes 1 Base and applicator See details on pages 12 13 1 with filter included consumable cartridge and its optical filter included in the applicator of your 1 pencil of work and sharpener See details on page 42 1 working gel See details on page 42 1 safety glasses See details on page 42 ...

Page 5: ...at an abnormally high rate An device that has lost its warranty will not be able to recover it REMINDER Only E Swin is authorised to sell and its acces sories etc on its own website www e swin com CAUTION YOU MUST KEEP ALL THE ELEMENTS OF THE ORIGINAL PACKAGING BOXES PACKAGING ETC The manufacturer s 2 year warranty will cover parts and labour only if the device is returned with all its elements in...

Page 6: ...7 ...

Page 7: ...er use with wet hands must never be used in the shower bath or in any place where water can splash the device applicator or base Never immerse the base of its applicator or the cartridge in water Never use if damaged never use in case of a functional anomaly appearing on the touch screen or following a fall non visible damage can be detrimental to your safety This device can be repaired only with ...

Page 8: ...lothes or any other object so as to prevent all risk of injury blockage or impairment The applicator tip must not touch the at the time of the flash Never use near an aerosol a heat source or any other electronic devices Do not stack on top of other electrical devices Your is provided with a power cord 2 meters long and an applicator cable 2 meters long Do not use any extension cables or any cable...

Page 9: ...kin On skin that has been sunburnt and whose recovery time is less than one month On skin lesions of unusual aspect you must first have a medical consultation with your doctor On high risk areas blemishes birthmarks warts unhealed wounds On moles if they are located on the zone to be treated they must first be protected specifically by covering them with the self adhesive provided with your On tat...

Page 10: ...take care about when using and also using artificial UV radiation Regarding high pressure UV dispensed by high powered machines it is advisable to wait a few days before or after such a session before starting treatment with Natural UV when exposed to sunlight after a treatment session with the it is imperative to use a sunscreen of very high protection on the treated areas for 2 weeks following t...

Page 11: ...GLOS 12 THE BASE Applicator Colour touch screen Applicator support area ...

Page 12: ...SARY 13 THE APPLICATOR Tip of optical guide Lower casing Air vents Mobile head Mobile head locking tab Start button Flash availability Upper casing ...

Page 13: ... woman and man 7 Thickness of the hair This area allows you to select the thickness of the hair from the thinnest bottom to the thick est top 8 Skin colour This area allows you to select the colour of the skin from the lightest bottom to the darkest top 9 Level of intensity The gauge represents the 6 levels of intensity of the issued flash The arrows adjacent to this gauge enable you to increase o...

Page 14: ...n is active it corresponds to an error message see page 52 18 Detection of the activation card this icon is only visible in case of RC and RC Multi 19 Temperature of the applicator This icon is not active dur ing normal functioning of the device If it blinks please refer to the corresponding error message page 52 20 Cartridge tube When it blinks it means that you can issue a flash Clicking on this...

Page 15: ......

Page 16: ... unplugged before you start disassembling the mobile head Before each use and before plugging in the you must check the integrity of the internal optical parts tube filter flat red piece of glass and optical guide The filter must be cleaned systematically before each hair removal session with the It must be clean and free of dust To proceed to the verification code Press simultaneously on the 2 lo...

Page 17: ... the accessible side of the filter with this cloth 8 Repeat the same procedure for the accessible part of optical glass 9 NOTE The filter must never be separated from its cartridge When cleaning is complete take the cartridge and align it with the applicator with the help of the red dots 10 Push it into the slide way of the applicator by pressing on it 11 so as to ensure that it is properly in pos...

Page 18: ... 2 PREPARE YOUR SKIN Your skin should be clean dry and free of any cosmetic product Do not apply any cream moisturiser oil or any other substance on your skin Shave the area to be flashed on the same day of the ses sion with It is imperative that the areas of the skin to be flashed are completely free of all hair by shaving and not by waxing depilation cream electric epilator or by any other hair ...

Page 19: ... B These icons are explained on pages 14 and 15 The menus are displayed temporarily Only the safety icons keep blinking Unlock the safety features screen C It is mandatory to validate each safety feature by pressing one by one on each safety icon the order of validation does not matter Once all the safety icons are validated all the other settings icons for the flash will be available If an icon h...

Page 20: ...ne of them has not been selected the icon will continue to blink IDENTIFY YOUR SILHOUETTE screen D Select man woman silhouette by clicking alternately on the frame 6 The selected silhouette stays on the screen the other silhouette disappears IDENTIFY THE THICKNESS OF THE HAIRS TO BE REMOVED screen E Choose the thickness of the hair 7 among the 4 thic knesses of hair proposed from the thinnest bott...

Page 21: ...esired intensity Issue a flash then wait 5 minutes after this flash to appreciate the skin reaction In the absence of skin reaction you can continue to flash the entire desired area or move the intensity up again by 1 notch and observe the reaction once again and so on IMPORTANT The darker the skin whether by photo type or tanning the more important it is to stay close to the minimum default power...

Page 22: ... gauge level 1 If flashing is on the beard the feeling can be significant We rec ommend that you place the gel in the fridge for 3 hours before flashing this area I am a woman I have dark skin I wish to remove the hair on my arms My selections will be as follows Woman The darkest skin 5th colour Hair 2nd thickness Intensity level gauge level 1 CASE STUDIES H I HAIR REMOVAL WITH ...

Page 23: ... has been ordered Use the activation card of your cartridge Insert the card on the upper support clip located in the base of the applicator Leave the card in this slot throughout the entire hair removal session At the end of the session remove the activation card take care not to damage it and store it in its case Follow the procedure to switch off the device THE ______ ...

Page 24: ...to be flashed move the applicator along the marked out area refer to the next page to know how to issue a flash The applicator s positioning leaves a foot print on the skin which enables you to see the area that has just been treated Thus from one flash to another it is very easy to distinguish between an area that has already been flashed and another area that has not yet been An overlap of about...

Page 25: ...e safety glasses protecting your eyes eyebrows eyelashes If you are planning to flash a large area do not apply the gel over the entire area from the beginning as it will dry out and lose its effectiveness in terms of optical transmission Therefore apply the gel as you progress onto the area concerned Once the gel has been used on the skin and has been flashed it should under no circumstance be co...

Page 26: ...rned green you will not be able to issue the flash Make sure that you stretch the skin where it is the thinnest so that the glass tip optical guide of the appli cator is in contact with the skin and that you have properly removed all hairs from the area to be flashed 14 15 16 17 18 19 NOTE For each flash the treated area corresponds to the range covered by the tip of the optical guide i e 3 x 2 6 ...

Page 27: ... parts to cool down properly The fans located in the base for their part only stop when the device is unplugged In case of sensitive skin and after a hair removal session with the do not use any hair removing cream for a whole week on the areas that have been flashed NOTES After the hair removal session small red spots may appear this is a normal reaction and will disappear quickly Once the hair r...

Page 28: ...31 ...

Page 29: ...chnical department is authorised to ask you to change the cartridge refer to page 40 of this instruction manual STEP 1 The cartridge must be changed when the number of flashes displayed is equal to 0 When this happens the lamp icon 20 appears but does not blink screen J You can monitor your usage on the touch screen at any time J __CHANGING THE STEP 2 Before turning off and unplugging your device ...

Page 30: ...taneously on the 2 loc king tabs of the mobile head 23 and remove it Once the mobile head is removed the cartridge with filter presents itself in the applicator 24 Remove the cartridge from the applicator strongly pinch the filter support 25 and pull 26 The optic cartridge with filter now appears 27 it is imperative to only hold the plastic parts 23 24 S 25 26 27 The explanation of the different p...

Page 31: ...tilation grid which is also marked by a red dot You must therefore align the 2 red dots Push it into the slide way of the applicator by pressing on both sides 29 so as to ensure that it is properly maintained 30 Re attach the mobile part of the applicator by pressing simultaneously on the locking tabs of the mobile head 31 making sure to align the internal red dot on the head with the red dot on t...

Page 32: ...f you accidentally touch the tube or its reflector we urge you to send us back your cartridge to proceed to an exchange STEP 6 Before repositioning the mobile head of the applicator you must always clean the filter located directly on the cartridge with the spray but use it only on its accessible surface It is strictly forbidden to spray directly on the filter It must be sprayed before hand on a c...

Page 33: ...hange the cartridge Plug in your device The screen is black Touch anywhere on the screen When changing the cartridge once the new cartridge is inserted you must press on the icon representing the lamp 20 Figures 1 and 2 21 correspond to the 2 successive activation codes that need to be entered to activate the new cartridge The number 1 appears screen K With the help of the navigation icons 12 ente...

Page 34: ...correct the current menu will be displayed again as well as the number of flash credit If the codes are wrong an error message will be displayed error message no 11 or 12 depending on the scenario please refer to page 52 for their meanings and the warning icon 17 will blink In each case you must pro ceed to entering the full code You must click on the valida tion icon 14 to proceed again to enteri...

Page 35: ...its case To do this once you open the plastic case image 37 you must place each of your thumbs on the 2 clips and exert lateral pressure towards the outside of the case image 38 in order to break the clips You can now remove the new cartridge from its case 37 38 S S STEP 2 KEEPING THE ELEMENTS AT THE TIME YOU RECEIVE YOUR NEW CARTRIDGE When you receive the new cartridge you must keep the following...

Page 36: ...addings of the cartridge case and place them on either side of the plastic case by completely propping them between these 2 foam paddings Place the case in the box image 42 Then place the cardboard box inside the brown strengthened cardboard box image 43 STEP 4 PREPARING FOR DISPATCH Close the brown box making sure to firmly scotch tape either side of the flaps image 44 Stick the self adhesive Col...

Page 37: ...number 2 located next to icon 20 will blink you must enter the second code Enter your code a second time confirmation entry and revalidate validation icon 14 When the input is completed you will automatically go back to the previous menu However if the second code entered is different from the first code the warning icon 17 will blink and the error message no 14 will be displayed You must therefor...

Page 38: ... same steps as those described previously If you have mistakenly selected the lock icon 16 and that you do not wish to enter a personalised PIN code click on the go back icon 13 IMPORTANT If you cannot remember the PIN code you have entered you must send us back your so that our technical depart ment can unlock your device This service is not included in the warranty you will therefore be billed f...

Page 39: ...43 ...

Page 40: ... an irreversible way Do not to block the venti lation grid located on the upper part by covering the base of the with a cloth Do not place the base of the on a soft surface such as a bed as it will lead to a possible obstruction of the lower ventilation grid Do not cover or block the ventilation grid located on the applicator with your hands or in any manner whatsoever ...

Page 41: ...ely not the metal parts the lamp the electrodes the tube or the reflector Do not attempt to open your device all interventions must be carried out by people duly authorised by the manufacturer NOTE Unlike the fans located inside the applicator the other ones located inside the base of will only stop once the device is unplugged ...

Page 42: ...he skin and flashed the should under no circumstance be collected and reused on another area A gel that has been flashed is likely to lead to an alteration of its optical characteristics At the end of the session it must be removed from the surface of the skin with a wet towel or by taking a shower It should be from the optical parts and from the mobile part of the applicator with the help of a sl...

Page 43: ...screen Never spray direct ly on the touchscreen Take a dry cotton cloth and spray on the cloth and then wipe the screen with this dampened cloth Finish cleaning with a dry part of the cloth Made in France These self adhesive are used to cover the small areas that must not be flashed e g moles They must be placed after shaving and before applying the gel It is then possible to flash any area withou...

Page 44: ...hscreen The screen must be cleaned with a clean cloth that has been dampened with never spray directly on the touch screen Power cord Check its perfect condition must not be pinched or crushed no bare wires Clean with a cloth that has been dampened with water without any additives APPLICATOR Mobile Head Cleaning the optical parts internal and external of the mobile head with the spray before and a...

Page 45: ...no elements likely to clog them STORAGE Store your and its accessories in its box Place your in a room where the room temperature does not exceed 25 C for immediate use away from excessive moisture e g bathroom and in a place where it cannot be subjected to vibrations e g placed on a washing machine If the device suffers from an impact it will be necessary to check the optical parts in their entir...

Page 46: ...o the patient Part to be applied Type BF Class II Medical device Device must be used indoors Keep the device dry Keep away from light and heat It is compulsory to refer to the instructions in the user manual Operating conditions supply voltage alternating Current frequency of the mains voltage power Warning dangerous voltage device Global safety mark for electronical devices Respect upper and lowe...

Page 47: ...n be recycled and reused E Swin SAS is affiliated to an eco organisation that is responsible for collecting and pro cessing of end of life products Do not dispose of your old product in your ordinary trash bag for domestic waste Please keep informed about local structures in place for the selec tive collection of electrical and electronic appliances marked by this symbol Please choose one of the f...

Page 48: ... the new cartridge by carefully following the handling and access instructions cartridge code Unplug your device and plug it back follow instruc tions on page 29 If the problem persists contact our technical depart ment by visiting your customer page at www e swin com and clicking on Contact Us and After Sales Service Wait for the procedure that cools down the optical parts of the applicator to fi...

Page 49: ...en disposing of packaging and consumables Wherever possible try to promote recycling STANDARDS CERTIFICATIONS E SWIN SAS the company that is the exclusive manufacturer of the device has been awarded an ISO 9001 and ISO 13485 certification COMPLIANCE E Swin SAS declares that the complies with the essential requirements of Directive 93 42 EEC Annex II Article 3 and has the CE mark under the responsi...

Page 50: ...54 SHOWROOM PARIS FRANCE 34 rue Brunel 75017 Paris FRANCE 33 1 45 74 22 22 devices and their accessories are also available in our showroom ...

Page 51: ...onsible for any accident that may occur due to improper use or non compliance with the prescriptions of the present manual or the various information provided through the labelling or the touchs creen of the The manufacturer s two year warranty will cover parts and labour only if the device is returned with all its elements in its original packaging You must keep the whole original packaging in wh...

Page 52: ...0499 2 0 1 3 www e swin com 5 rue de la Noue 78113 Adainville FRANCE version 1 2 EN 09 2014 PLCM 1407 035_00 ...

Reviews: