background image

INSTRUCTION MANUAL 

GNExB1X05  
Flameproof Xenon Beacons  
For use in Flammable Gas and Dust Atmospheres

 

 

_______________________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           www.e2s.com              Tel: +44 (0)208 743 8880 

Document No.D155-00-201-IS 

Issue 3        28-11-22                         Sheet 1 of 5

 

                                                           

GNExB1X05
 

 

1)  Product Table 

 

 

Ensure the system power supply is capable of providing  the maximum current required for all  beacons. Review associated cable 
size, length and quantity of beacons on each circuit. 

 

2)  Warnings 

 

 

 

POTENTIAL ELECTROSTATIC CHARGING HAZARD 

 

DO NOT OPEN WHEN AN EXPLOSIVE                    
ATMOSPHERE IS PRESENT 

 

ALL ENTRIES M20 X 1.5 

 

IF TEMPERATURE EXCEEDS 70ºC AT ENTRY OR 80ºC 
AT BRANCHING POINT USE SUITABLE RATED CABLE 
AND CABLE GLANDS 

 

3)  Marking & Rating Information 

 
All  units  have  a  rating  label,  which  carries  the  following 
important information:- 
 

 

Unit Model. 

 

Voltage Range 

 

Nominal Voltage 

 

Max. Current 

 

See Table 1 for electrical ratings of each Unit Model 
 

3.1)  ATEX / IECEx / UKEX Ratings 

 

Standards 

EN IEC 60079-0:2018 / IEC60079-0:2017 (Ed 7): 

Explosive Atmospheres - Equipment. General Requirements 

EN60079-1:2014 / IEC60079-1:2014 (Ed 7): 

Explosive Atmospheres - Equipment Protection by Flameproof 
Enclosures "d" 

EN 60079-31:2014 / IEC 60079-31:2013 (Ed 2): 

Explosive Atmospheres - Equipment Dust Ignition Protection by 
Enclosure "t" 
 

Ratings 

GNExB2: 
X05DC012 
X05DC024 
X05DC048 
X05AC115 
X05AC230

Ex db IIC Gb T6 Ta -50°C to +40°C 
Ex db IIC Gb T5 Ta -50°C to +55°C 
Ex db IIC Gb T4 Ta -50°C to +70°C 
Ex tb IIIC Db T110°C Ta -50°C to +70°C 

 

 

Standard 

Model 

Nom. 

Voltage 

Voltage Range 

Nom. 

Operating 

Current*

 

Max 

Current 

ATEX / 

IECEx / 

UKEX 

GNExB1X05DC012 

12Vdc

10-14Vdc

437mA 

587mA

GNExB1X05DC024 

24Vdc

20-28Vdc

254mA 

266mA

GNExB1X05DC048 

48Vdc

42-54Vdc

158mA 

175mA

GNExB1X05AC115 

115Vac

110-125Vac 50/60Hz 

95mA 

121mA

GNExB1X05AC230 

230Vac

220-240Vac 50/60Hz 

54mA 

88mA

*Rate at 1Hz 
 
The table shows the input current taken by the various beacons. 
A supply voltage variation of +/-10% outside the voltage range is permissible. 
Nominal current at nominal voltage and 1Hz flash rate. 
Max. rated current at worst case supply voltage and flash rate.

Table 1: Electrical Ratings. 

Summary of Contents for GNExB1X05

Page 1: ...1 for electrical ratings of each Unit Model 3 1 ATEX IECEx UKEX Ratings Standards EN IEC 60079 0 2018 IEC60079 0 2017 Ed 7 Explosive Atmospheres Equipment General Requirements EN60079 1 2014 IEC60079...

Page 2: ...only Group IIIA Combustible Flyings Group IIIB Non conductive Dust Group IIIC Conductive Dust Maximum Surface Temperature for Dust Applications ATEX IECEx UKEX only GNExB2X05 110 C Equipment Category...

Page 3: ...al codes that may apply and should only be carried out by a competent electrical engineer who has the necessary training 7 2 Cable Selection and Connections When selecting the cable size consideration...

Page 4: ...It is important to note that stopping plugs cannot be fitted onto adapters only directly onto the M20 entries Any other adapters used must be suitably rated as per the applicable standards If the ins...

Page 5: ...ints route 2H 2 As an unvoted item i e hardware fault tolerance of 0 at SIL 2 The product was assessed against failure modes Failure respond to an input by lighting a beacon Spurious light output desp...

Page 6: ...TOLERANCES TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNAT...

Page 7: ...F ISSUE SHOWN ABOVE DRAWING TO BS8888 2000 GEOMETRIC TOLERANCES TO ISO1101 1983 LINEAR DIMENSIONAL TOLS ANGULAR DIMENSIONAL TOLS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE D...

Page 8: ...B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db IIC T4 T6 Gb II 2D Ex tb IIIC T80 C T138 C D...

Page 9: ...Date and Place of Issue London 03 12 2021 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on t...

Page 10: ...e Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 2G Ex db IIC T4 T6 Gb II 2D Ex tb IIIC T80 C T138 C Db IP6X Dust P...

Page 11: ...r Date and Place of Issue London 24 02 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed o...

Page 12: ...Page left Intentionally blank...

Reviews: