eG9887 revised 11/18
eagle Foodservice equipment, eagle Mhc, specFAB, and retail Display are divisions of eagle Group. ©2018 by the eagle Group
• 100 Industrial Boulevard, Clayton, Delaware 19938-8903 U.S.A. • www.eaglegrp.com
• Phone: 302/653-3000 • (Foodservice) 800/441-8440 • (MHC/Retail) 800/637-5100
• Fax: 302/653-2065
1)
Cut holes as required in counter top and front panel. See chart for cut out sizes.
See figure 1 for cutout positioning.
2)
Remove screws holding control panel to box and remove control panel to expose field-
wiring terminals.
3)
Apply a bead of NSF listed silicone adhesive to underside of top flange. Pass control box
through top opening and work through cutout in front panel. Seat unit to counter top.
4)
From underneath insert a long, flat head screwdriver into the slots in the locking angles.
Twist clockwise 120˚ to lock unit securely to top.
5)
Install control box securely in front panel cutout with #8 sheet metal screws in top and
bottom flanges.
6)
Make electrical connections at terminal block as required. Connect unit to dedicated
electrical circuit with properly sized circuit breaker that meets the requirements of
NEC Article 422 and any local electrical codes. See unit model/serial for electrical
ratings. Replace control panel and attach knobs.
Note: All units are shipped from the factory wired for single-phase operation; all but the
single-well units are field-convertible for three-phase operation, see wiring diagram
for details.
7)
A drain manifold with ball valve is provided on all units with drains. Location of the valve
is left to the discretion of the installer*. Install provided pipe plug on end opposite ball
valve. Use of a suitable pipe-sealing compound is recommended. When tightening
connections, back up manifold fittings with a wrench to prevent damage to the manifold.
*on units with AutoFill
®
Water system, the ball valve will be located on the left end.
CAUTION
insPect contents iMMeDiAteLY AnD FiLe cLAiM With DeLiVerinG cArrier
For AnY DAMAGe. SAVe YOUr BOX AND ALL pACKINg MATerIALS.
You Are resPonsiBLe For DAMAGe to Your unit iF returneD iMProPerLY PAcKeD.
Installation must meet local electrical and plumbing codes. Installation
must allow access for service. Unit shall be accessible for servicing
from the bottom.
Please retain
this manual for
future reference.
replacement parts List
334567 . . . . . . . . . . . element 1600W @ 240V
334567 . . . . . . . . . . . element 1200W @ 208V
334571 . . . . . . . . . . . element 1200W @ 240V
334568 . . . . . . . . . . . element 1200W @ 120V
302353 . . . . . . . . . . . Light indicator
309750 . . . . . . . . . . . thermostatic control
301986 . . . . . . . . . . . control Knob
Parts are the same for all model numbers, quantities will vary.
part #
description
replacement parts List— AutoFill
®
Water System
337968 . . . . . . . . . . . AutoFill
®
controller @ 120V
349784 . . . . . . . . . . . AutoFill
®
controller @ 208/240V
338518 . . . . . . . . . . . solenoid Valve @ 120V
349785 . . . . . . . . . . . solenoid Valve @ 208/240V
338390 . . . . . . . . . . . AutoFill
®
switch
338473 . . . . . . . . . . . AutoFill
®
reservoir
INSTALLATION/OperATINg INSTrUCTIONS
SGDI Drop-Ins
(continued on Page 2)
model
top
control
umbilical
number
cutout
cutout
length
sGDi-1 . . . . . 23 3/8˝ x 16 3/8˝ . . . . . 5˝ x 8˝ . . . . . . . . . 36˝
sGDi-2 . . . . . 23 3/8˝ x 30 3/8˝ . . . . . 5˝ x 17˝ . . . . . . . . 24˝
sGDi-3 . . . . . 23 3/8˝ x 44 3/8˝ . . . . . 5˝ x 17˝ . . . . . . . . 24˝
sGDi-4 . . . . . 23 3/8˝ x 57 3/8˝ . . . . . 5˝ x 33 7/8˝ . . . . . 24˝
sGDi-5 . . . . . 23 3/8˝ x 71 3/8˝ . . . . . 5˝ x 33 7/8˝ . . . . . 24˝
sGDi-6 . . . . . 23 3/8˝ x 85 3/8˝ . . . . . 5˝ x 33 7/8˝ . . . . . 24˝
** Denotes minimum installation spacing from
cutouts to vertical cabinet walls per uL listing.
figure 1
instruction sheet
#334591