background image

HV6002 / 6003

OPERATING INSTRUCTION MANUAL

Thank you for purchasing the SprayPort® from Earlex Professional 6000 Series.

This highly versatile HVLP System (high volume of air, low pressure painting) can be 

used for a wide variety of applications.

BEFORE USE – PLEASE READ THE MANUAL AND SAFETY INSTRUCTIONS.

Please retain for future reference.

To register your product visit www.sprayport.com

®

Summary of Contents for SprayPort HV6002

Page 1: ...x Professional 6000 Series This highly versatile HVLP System high volume of air low pressure painting can be used for a wide variety of applications BEFORE USE PLEASE READ THE MANUAL AND SAFETY INSTRU...

Page 2: ...ray area as the air hose will allow especially when using solvent based coatings EQUIPMENT MISUSE HAZARD WARNING The use of any accessory or attachment other than those recommended in this instruction...

Page 3: ...lters for a continuous and clean air flow Air is fed to the gun through the lightweight HyperFlex hose The HV6000 series sprays a wide range of paint with or without dilution To achieve the desired re...

Page 4: ...on Part No 1 Air Filter 0PACC62 2 Cordset US 0PACC130 IND 0N0322 3 Circuit Breaker US 15 AMP 0N0080 IND 8 AMP 0N0078 4 Power Inlet Connector n a 5 Power Switch 0L1843 6 Air Outlet Hose Attachment n a...

Page 5: ...for operation refer to Spray Gun Instruction Manual supplied separately Plug cordset into turbine unit Attach the nut at the end of the air hose to the air outlet on the turbine ensuring it is screwe...

Page 6: ...urbine unit filters and the gun are clean and dry before operating NEVER leave the turbine unsupervised while plugged in SHUTTING DOWN If leaving your sprayer for less than 1 hour Turn the power off O...

Page 7: ...ubmerge into or flush through with water or any chemical Regularly check for cracks leaks and holes Replace if necessary Cleaning the unit Keep the outer surface clean by wiping with a damp cloth Do n...

Page 8: ...d air hose for blockages Turbine has no power No power at supply Check the power supply Cable fuse has blown Where applicable check fuse and replace if necessary Circuit Breaker has tripped Reset the...

Page 9: ...en the grounding instructions are not completely understood or when in doubt as to whether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the prope...

Page 10: ...10 Notes...

Page 11: ...11 Notes...

Page 12: ...fications to the equipment or deviations from the recommended procedures accidental damage or any related action that impairs or abuses intended use and care of Earlex equipment will also void warrant...

Reviews: