background image

TABLE OF CONTENTS

Page 12

4.5      TECHNICAL SPECIFICATIONS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page11

4.4      USER NOTES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 10

4.3      CLOCKING / APPLICATION DIAGRAM

. . . . . . . . . . . . . . . . . . . . . . . .

Page 9

4.2      FACTORY DEFAULT CHART

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 8

4.1      EIA INTERFACE CHART

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 8

4.0 - APPENDIX

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 7

3.5      MODEM (DCE) AND TERMINAL (DTE) CONNECTION

. . . . . . . . . . .

Page 7

3.4      DEFAULT CONFIGURATION SWITCH SETTINGS

. . . . . . . . . . . . . . . .

Page 6

3.3      POWER / GROUND CONNECTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6

3.2      VOLTAGE FUSES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6

3.1      INPUT VOLTAGE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 6

CHAPTER 3 - INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5

2.13      DCE / DTE SWITCHES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5

2.12      NORMAL OR FORCED CLEAR TO SEND (CTS) (PORTS 1-4)

. . . . .

Page 5

2.11      ENABLE CONTROL (PORTS 1 - 4)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4

2.10      CASCADING OR CONCATENATION

. . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4

2.9      UNEXPLAINED STREAMING TERMINALS

. . . . . . . . . . . . . . . . . . . . . .

Page 4

2.8      MANUAL DTE/DCE REMOVAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3

2.7      SYNC AND ASYNC SELECTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3

2.6      ANTI-STREAMING

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3

2.5      SUBCHANNEL SERVICE MODES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3

2.4      RS-232 ELECTRICAL INTERFACE

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

2.3      CLOCKING, INTERNAL AND EXTERNAL

. . . . . . . . . . . . . . . . . . . . . . .

Page 2

2.2      REAR PANEL CONNECTORS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

2.1      FRONT PANEL INDICATORS AND SWITCHES

. . . . . . . . . . . . . . . . . .

Page 2

CHAPTER 2 - BASIC OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

1.2      THEORY OF OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 1

1.1      FUNCTIONAL DESCRIPTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 1

CHAPTER 1 - INTRODUCTION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for DMM-4DC

Page 1: ...5 2 13 DCE DTE SWITCHES Page 5 2 12 NORMAL OR FORCED CLEAR TO SEND CTS PORTS 1 4 Page 5 2 11 ENABLE CONTROL PORTS 1 4 Page 4 2 10 CASCADING OR CONCATENATION Page 4 2 9 UNEXPLAINED STREAMING TERMINALS...

Page 2: ...MIXING MODULE 48VDC POWER SUPPLY January 22 2002 Manufactured By East Coast Datacom Inc FOR TECHNICAL SUPPORT CALL East Coast Datacom Inc 245 Gus Hipp Blvd STE 3 Rockledge FL 32955 TEL 800 240 7948 or...

Page 3: ...nt is free from any defects in materials and workmanship The warranty period shall be three 3 years from the date of shipment E C D s sole obligation under its warranty is limited to the repair or rep...

Page 4: ...er is provided In applications where the master port and the selected port provide their own clocks data is clocked into the buffer at the receive clock rate of the active port and clocked out using t...

Page 5: ...g switches are provided for each DTE port for isolating or removing a streaming terminal Each DTE port has its own switch and operates independently To disable a subchannel simply push the switch A ch...

Page 6: ...TS TO CTS DELAY RTS to CTS delays of 0 5 10 and 20ms are user selectable 2 6 ANTI STREAMING 2 6 1 AUTOMATIC DTE REMOVAL The DMM 4DC incorporates circuitry that will when enabled automatically remove a...

Page 7: ...ll other DTE s will now continue to be serviced by the DMM 4DC However you still need to fix the offending DTE or DCE device that has RTS or DCD continually raised 2 9 UNEXPLAINED STREAMING TERMINALS...

Page 8: ...and DTE Slide BOTH switches to the same position to configure each of the RS 232 ports as a DTE or a DCE interface When set to DCE the RS 232 port MUST connect to a DTE device When set to a DTE the R...

Page 9: ...pect the fuses Spare fuses may be obtained by calling East Coast Datacom Replacement fuse Part 714003 or by calling Little Fuse at 312 824 3024 Part 218 315 Shurter Inc at 707 778 6311 Part 034 3112 P...

Page 10: ...more of the default settings to be changed it will be necessary to remove the top cover of the DMM 4DC Remove the DC Power source or Disconnect the DC Power before servicing the unit Removal of the t...

Page 11: ...iming DD 115 17 X Send Timing DB 114 15 Voltage 9v 10 Voltage 9v 9 X Receive Line Detector CF 109 Signal Ground AB 102 7 X DCE Ready CC 107 6 X Clear To Send CB 106 5 X Request To Send CA 105 4 X Rece...

Page 12: ...F OFF OFF OFF OFF OFF OFF 3 4 BAUD RATE SELECT SW11 57600 28800 14400 7200 3600 1800 900 450 5 ON OFF ON OFF ON OFF ON OFF 6 ON ON OFF OFF ON ON OFF OFF 7 ON ON ON ON OFF OFF OFF OFF 8 ON ON ON ON ON...

Page 13: ...1 MODEM 2 MODEM 3 MODEM 4 SET TO EXTERNAL TRANSMIT CLOCK TERMINAL TIMING MODEM SLAVE SET TO RECEIVE CLOCK SLAVE CLOCK DMM 4 CLOCKING AND SIGNAL ROUTING DIAGRAM CSU DSU TERMINAL TERMINAL DIGITAL MIXIN...

Page 14: ...4 4 USER NOTES DMM 4DC OPERATIONS MANUAL Page 11...

Page 15: ...ows normal RTS CTS handshaking or has option for Forced CTS on Ports 1 4 JP1 JP4 RTS To CTS Delay Selectable RTS to CTS delays of 0 5 10 and 20ms Front Panel Indicators Power Transmit Data Receive Dat...