background image

PUMP

General User/Safety Guide

HARVEST 2 PUMP

www.easycaresystems.co.uk

www.easycaresystems.co.uk

Summary of Contents for HARVEST 2

Page 1: ...PUMP General User Safety Guide HARVEST 2 PUMP www easycaresystems co uk...

Page 2: ...2 www easycaresystems co uk...

Page 3: ...INFORMATION FOR THE USER 3 3 SAFETY INFORMATION FOR THE USER 3 4 SYMBOLS USED 3 4 SYMBOLS USED 3 5 CLEANING DISINFECTION 3 6 SERVICING MAINTENANCE 3 7 SERVICE LIFE DISPOSAL TECHNICAL SPECIFICATION TE...

Page 4: ...py may be reduced All hoses must be free of kinks twists and must be properly connected and positioned so as not to cause any obstruction Do not position the pump in a way that prevents access to the...

Page 5: ...e for continuous use Do not modify the mattress cushion or pump unit in any way Do not connect to any other medical device or equipment Not for use in an oxygen enriched environment Not for use in an...

Page 6: ...est Healthcare supply a pump and mattress but it is the user s responsibility to ensure each system meets the guidelines set out in the pump and mattress guide shown below Failure to do this could put...

Page 7: ...rrect installation Operation by persons who have not been instructed in its use Using the system with non approved parts accessories Using the system if any of the components are damaged or faulty GEN...

Page 8: ...instruct each user in the safe operation of this system before it is put into service for the first time Advise the user of any hazards which may occur if not handled correctly Only persons who have b...

Page 9: ...is way up Keep dry Recycling symbol Refers to packaging that can be recycled cardboard Fragile handle with care This product must be disposed of in a designated refuse bin for waste electronic devices...

Page 10: ...igns of wear must be rectified without delay Only original spare parts from Harvest Healthcare may be used otherwise all guarantees or warranties will be invalidated See pages 16 17 for Routine Mainte...

Page 11: ...Dimensions Weight Air Flow Output Pressure Setting HPU2 10 minutes 130 x 140 x 270mm 1 7 kg 9 lpm Manual PUMP POWER REQUIREMENTS Power Rating Voltage Fuse Medical Classification Safety Standards 9VA A...

Page 12: ...dicator Static Mode Bed Hooks PUMP OVERVIEW A B D F E C G G Power failure The alarm will sound until the power is reinstated If the Mute button is pressed to silence the alarm you must press the on of...

Page 13: ...hen the pump is switched on for the first time it will enter Start up Mode and inflate all the cells The Alternating Mode LED will flash to indicate that the pump is in Start up Mode Once all the cell...

Page 14: ...action stops in this mode TRANSPORT MODE To turn off the system press the power button to OFF and unplug from the mains supply When the mattress is fully inflated set the pump to the service user s a...

Page 15: ...tresses should be thoroughly rinsed with clean water to remove any residues This will help prevent any long term compatibility issues associated with disinfectant residues Alternatively disinfection m...

Page 16: ...with a mild antiseptic solution All cells are replaceable and can be sourced from Harvest Healthcare POWER UNIT Disconnect the power unit from the electricity supply before carrying out maintenance re...

Page 17: ...2 months by Harvest Healthcare approved personnel using genuine Harvest Healthcare spare parts SERVICING YOUR SYSTEM Failure to follow the service schedule may invalidate future warranty claims Guaran...

Page 18: ...p is connected to is working correctly 1 2 3 4 Connect the pump to the nearest working mains outlet Replace the plug fuse with the correct 5A fuse Try a different device in the mains outlet 1 2 3 IF P...

Page 19: ...NOTE Inflation can take up to 30 minutes The hoses are routed correctly not kinked and connected to the pump correctly The CPR valve is not trapped and is in the closed position 1 2 There are no leak...

Page 20: ...equentially CHECK THAT FAULT STAGE 2 CHECK The system does not appear to be alternating Check that the static mode is not turned on Carefully mark one of the inflated cells with a pen Ensure that ther...

Page 21: ...s is uncomfortable Check the comfort setting on the pump Set the pump to the correct setting using the guide on the front of the pump case Contact Harvest Healthcare technical support Before calling P...

Page 22: ...3 PU204 PU205 Power Lead 5 Metres Inlet Power Lead Label Panel Tactile Timer and Motor Front Casing HPU2 Harvest 2 Pump only PU200 Connector PU206 Rear Casing PU207 PU208 Bed Hooks PCB UN012 Filter PU...

Page 23: ...uipment has been used for the purpose for which it was intended That the usage has been on a fair wear and tear basis This does not include user damage That Harvest Healthcare s cleaning disinfecting...