background image

©2008 Easy Heat  

www.easyheat.com

 

14055-001 Rev. 3

SA-1

Automatic Snow/Ice Melting Controller

Installation & Operation Instructions

GENERAL

The  SA-1heating  cable  controller  has  been  designed 

and manufactured for the sole intended use of controlling 
heating cables in residential and commercial snow melting 
applications  such  as:  sidewalks,  driveways,  parking 
garage  entrances  and  drive-through.  The  SA-1  uses 
microcontroller technology to reduce energy consumption 
by  energizing  the  heating  cable  only  when  the  right 
conditions of temperature and snowfall occur. 

The main components of the SA-1are shown in Fig.1. 

The  snow  and  temperature  sensors  detect  snow  or  ice  
conditions and activate, through a power relay, a heating 
cable. 

Another feature of SA-1 is the LED indicator light. This 

light turns red if the snow sensor is dirty and needs to be 
cleaned. The red light will switch off automatically when 
the snow sensor is cleaned. The LED turns green every 
time the power relay is activated and will switch off if the 
power relay is off.

Improper  installation,  use  and/or  maintenance  of  the 

SA-1  can  cause  fire,  electrical  shock  and/or  result  in 
snow build-up.  

WARNINGS

1.  This  is  not  a  “do-it-your-self”  product.  A  qualified 

electrician must install the SA-1.

2.  If  after  carefully  reading  these  instructions  you  still 

have  questions  regarding  installation,  operation  or 
maintenance of this product, call the numbers listed 
for assistance.

3.  Prior to installation, check the SA-1 body enclosure or 

wires for possible shipping damages. Do not install a 
damaged SA-1 controller.

4.  All heating cables, controls & associated systems must 

be installed in compliance with the latest editions of 
all applicable electrical codes and ordinances.

5.  These instructions must be saved and made available 

to owners or users of this product and/or transferred 
to future owners.

6.  Any heating cable that is to be connected to the SA-1 

must  be  installed  according  to  the  manufacturer’s 
instructions.

7.  Do  not  connect  more  than  16  Amp  load  to  the 

SA-1 (See Fig. 2 & 3). Risk of fire, electric shock or 
accumulation of snow can result from a larger cable 
or from multiple cables being connected.

8.  Secure the SA-1 in an area free of obstructions such 

as trees, shrubs, etc.  to prevent any damages to the 
snow sensor.

9.  Avoid excessive shock or vibration.
10.  Do not touch the surface of the moisture sensor, it is 

a hot surface.

Moisture Sensor

LED Indicator

Mounting Connector 

.5" (12.70mm) NPT

SA-1 

Enclosure

Figure 1

Temperature Sensor

US  T. (800) 537-4732 / F. (888) 324-2440