background image

200 A 35 kV class “LE” series elbow installation instructions

COOPER POWER

SERIES

Loadbreak Apparatus 

Connectors 

MN650010EN

Effective May 2015
Supersedes S500-41-1 March 2011

Summary of Contents for 200 A 25 kV class

Page 1: ...200 A 35 kV class LE series elbow installation instructions COOPER POWER SERIES Loadbreak Apparatus Connectors MN650010EN Effective May 2015 Supersedes S500 41 1 March 2011...

Page 2: ...NY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no...

Page 3: ...dling and Storage 1 Quality Standards 1 INSTALLATION INSTRUCTIONS Installation Instructions 2 Preparation of Concentric Neutral Cable 3 Elbow and Loadbreak Probe Installation 4 OPERATING PROCEDURES Lo...

Page 4: ...afety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all locally approved safety procedures when working around high and low volt...

Page 5: ...IONAL LOCKING RING THREE PHASE PROBE INSULATED CUFF ARC FOLLOWER PULLING EYE TEST POINT CAP DRAIN WIRE TAB LOADBREAK BAND PEROXIDE CURED SEMI CONDUCTING SHIELD INSULATION ENCAPSULATED CONDUCTIVE INSER...

Page 6: ...Cable Cutters Clampstick Personal Protection Equipment For detailed instructions please see pages 3 4 Table 1 Crimp Chart Connector Size AWG or kcmil Catalog Number Nominal Barrel Diameter Burndy Kear...

Page 7: ...the compression connector prior to crimping to ensure proper thread engagement Place the coppertop bimetal connector on the conductor Make sure the threaded hole in connector faces the apparatus bush...

Page 8: ...elbow Step 7 By hand thread loadbreak probe into threaded eye of coppertop connector When tight use the provided installation tool to properly torque the loadbreak probe Proper torque is applied when...

Page 9: ...vices to system ground per appropriate Installation Instructions All associated apparatus must also be grounded Secure elbow eye firmly onto clampstick and lock Twist clampstick clockwise until the el...

Page 10: ...This page intentionally left blank 6 200 A 35 KV CLASS LE SERIES ELBOW INSTALLATION INSTRUCTIONS MN650010EN May 2015...

Page 11: ...This page intentionally left blank 7 200 A 35 KV CLASS LE SERIES ELBOW INSTALLATION INSTRUCTIONS MN650010EN May 2015...

Page 12: ...wer and Kearney are valuable trademarks of Eaton in the U S and other countries You are not permitted to use the trademarks without the prior written consent of Eaton Burndy is a registered trademark...