5P 750VA -1.5 KVA EU_EN 

Installation and 
user manual 

5P750RC 

5P1000RC 

5P1500RC 

Summary of Contents for 5P1000RC

Page 1: ...Page 1 ENGISH Copyright 2015 EATON All rights reserved 5P 750VA 1 5 KVA EU_EN Installation and user manual 5P750RC 5P1000RC 5P1500RC ...

Page 2: ...level CISPR 22 EN 55022 Harmonics emission IEC 61000 3 2 Flickers emission IEC 61000 3 3 FCC 47 CFR Part 15 Subpart B Unintentional Radiators Class B Special symbols The following are examples of symbols used on the UPS or accessories to alert you to important information RISK OF ELECTRIC SHOCK Observe the warning associated with the risk of electric shock symbol Important instructions that must a...

Page 3: ...tream and be easily accessible The system can be disconnected from the AC power source by unplugging the input cable Check that the indications on the rating plate correspond to your AC powered system and to the actual electrical consumption of all the equipment to be connected to the system For PLUGGABLE EQUIPMENT the socket outlet shall be installed near the equipment and shall be easily accessi...

Page 4: ... Battery module connection 13 3 3 Rack installation 14 3 4 Wall mounting of rack model 15 3 5 Communication ports 16 4 Operation 17 4 1 Start up and Normal operation 17 4 2 Starting the UPS on Battery 17 4 3 UPS Shutdown 17 4 4 Operation on Battery Power 17 4 5 Return of AC Input Power 18 4 6 UPS remote control functions 18 5 Maintenance 19 5 1 Troubleshooting 19 5 2 Battery module replacement 20 ...

Page 5: ...mprises over 50 of recycled cardboard Sacks and bags are made of polyethylene Packing materials are recyclable and bear the appropriate identification symbol 01 PET Materials Abbreviations Number in 01 the symbols PET Polyethylene terephthalate PET 01 High density polyethylene HDPE 02 Polyvinyl chloride PVC 03 Low density polyethylene LDPE 04 Polypropylene PP 05 Polystyrene PS 06 Follow all local ...

Page 6: ...ation 2 1 Standard installations Rack model Description Weights kg lb Dimensions mm inch D xW x H 5P750RC 14 1 31 1 370 440 86 2 14 6 17 3 3 4 5P1000RC 15 0 33 1 370 440 86 2 14 6 17 3 3 4 5P1500RC 18 4 45 5 370 440 86 2 14 6 17 3 3 4 D W H ...

Page 7: ...ot for optional communication card 3 Primary group Outlets for connection of critical equipment 4 Group 1 programmable outlets for connection of equipment 5 Group 2 programmable outlets for connection of equipment 6 RS232 communication port 7 USB communication port 8 Connector for ROO remote ON OFF or RPO Remote Power Off control ...

Page 8: ... itself load status events measurements and settings 100 19min 1EBM The following table shows the indicator status and description Indicator Status Description Green On The UPS is operating normally Orange On The UPS is on Battery mode Red On The UPS has an active alarm or fault See trouble shooting in section 5 1 for additional information ...

Page 9: ...mally The UPS is powering and protecting the equipment In AVR mode 1 beep every 10 seconds The UPS is operating normally but the utility voltage is outside normal mode thresholds The UPS is powering the equipment through a Automatic Voltage Regulation device The equipment is still normally protected On Battery Battery LED is on 1 beep every 10 seconds A utility failure has occurred and the UPS is ...

Page 10: ... that can be changed by the user Submenu Available settings Default settings Local settings Language English Français Deutsch Español Русский Português Italiano Simplified Chinese Japanese Menus status notices and alarms UPS fault Event Log data and settings are in all supported languages English User selectable when UPS is powered for the first time LCD settings Modify LCD screen brightness and c...

Page 11: ...cation stays ON 1h30 min after UPS is OFF Disable Remote command Disable Enable If enabled shutdown or restart commands from software are authorised Enable RPO delay 0 s 1s 2 s 180 s Delays remote power off command 0 s Battery settings Automatic battery test No test Every day Every week Every month Available only if battery charge mode is set to constant charge Every week in constant charge otherw...

Page 12: ... mounting kits 11 Quick start safety instructions and environmental document 12 RS232 communication cable 13 USB communication cable Packing materials must be disposed of in compliance with all local regulations concerning waste Recycling symbols are printed on the packing materials to facilitate sorting ...

Page 13: ...S please connect the internal battery A Remove the center panel B Remove the left hand side of the front panel C Connect the battery module never pull on the wires D Attach the left hand side of the front panel by sliding it then by locking the push button E Attach the center panel A B C E D ...

Page 14: ...EN 3 3 Rack installation Follow steps 14 to 16 for model mounting on the rails Use provided screws on step 15 of installation Using a longer screw could present a safety risk The rails and necessary hardware are supplied by EATON ...

Page 15: ...Page 15 5P 750VA 1 5 KVA US_EN 3 4 Wall mounting of rack model Use provided screws on step 17 of installation Using a longer screw could present a safety risk ...

Page 16: ...max Power 1 It is not necessary to shut down the UPS before installing a communication card 1 Remove the slot cover 2 secured by screws 2 Insert the communication card in the slot 3 Secure the card cover with the 2 screws 1 Connect the RS232 12 or USB 13 communication cable to the serial or USB port on the computer equipment 2 Connect the other end of the communication cable 13 or 12 to the USB 7 ...

Page 17: ... See the Cold start setting in ON OFF Settings in section 2 6 To start the UPS on battery 1 Press the button on the UPS front panel until the UPS front panel display illuminates and shows a status of UPS starting The UPS cycles through Standby mode to Battery mode The indicator illuminates solid The UPS supplies power to your equipment 2 Check the UPS front panel display for active alarms or notic...

Page 18: ... These functions are obtained by opening a contact connected between the appropriate pins of connector 8 on the rear panel of the UPS see figures below Remote control connection and test 1 Check that the UPS is OFF and disconnected from the AC input source 2 Remove connector 8 after unscrewing the screws 3 Connect a normally closed volt free contact 60 V DC 30 V AC max 20 mA max 0 75 mm2 cable cro...

Page 19: ... Remove some of the equipment from the UPS The UPS continues to operate but may shutdown if the load increases The alarm resets when the condition becomes inactive End of battery life The end of the battery life is reached Contact your service representative for battery replacement Event An UPS event occurs Example Remote Power OFF the RPO contact has been activated to shutdown the UPS and now pre...

Page 20: ...ols with an insulated handle Mounting the new battery module Carry out the above instructions in reverse order To ensure safety and high performance use only batteries supplied by EATON Take care to firmly press together the two parts of the connector during remounting A Remove the center panel B Remove the left hand side of the front panel C Disconnect the battery module by separating the two con...

Page 21: ...ystem 56 5 to 70 Hz 60 Hz system 2 Output on battery power Voltage 120 V 10 6 3 Frequency 50 60 Hz 0 1 Hz Battery sealed lead acid maintenance free 2 x 12 V 7 2 Ah 2 x 12 V 9 Ah 3 x 12 V 9 Ah Environment Operating temperature range 0 to 40 C Storage temperature range 15 to 50 C Relative humidity 20 to 90 without condensation Noise level 45dB 1 The high and low thresholds can be adjusted using UPS ...

Page 22: ...s low and that the user warning must take action in light of the imminent break in the supply of power to the load Normal AC The AC power line supplying the UPS under normal conditions input Percent load Ratio of the power effectively drawn by the load to the maximum output of the UPS Personalisation It is possible to modify certain UPS parameters set in the factory Certain UPS functions can also ...

Page 23: ...Page 23 5P 750VA 1 5 KVA US_EN www eaton com Powerquality Eaton 5P ...