background image

AGSVX9000 Drives

Quick Setup Guide

Effective May 2013
New Information

CONTENT

STEP 1 — Keypad Operation Overview
STEP 2 — Standard Wiring Diagrams and Connections
STEP 3 — Start-Up Wizard
STEP 4 — Operating and Programming Menu 

Navigation

STEP 5 — Faults and Warning Indication
STEP 6 — Monitoring Menu 

Summary of Contents for AGSVX9000

Page 1: ...May 2013 New Information CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and Connections STEP 3 Start Up Wizard STEP 4 Operating and Programming Menu Navigation STEP 5 Faults...

Page 2: ...Alarm Indicates that there is one or more active drive alarm s Fault Indicates that there is one or more active drive fault s I O Terminal Indicates that the I O terminals have been chosen for control...

Page 3: ...the keypad which is always active unless disabled by the StopButtonActive parameter used to reset the active faults Reset Resets the active faults Local Remote Switches between LOCAL and REMOTE contro...

Page 4: ...running Stop the drive to edit these parameters See the AGSVX9000 Application Manual for identi cation of these parameters speci c to your chosen application Main Menu The data on the control keypad...

Page 5: ...TEP 2 Continued AGSVX9000 Power and Motor Wiring for Large Horsepower Drives 20 250 hp B M 3 L1 L2 L3 L1 L2 L3 B R External RFI Filter Optional BR Optional External Filter Optional BR Power Board 230V...

Page 6: ...MB Lout 15 14 DIN5 DIN4 12 11 CMA 24Vout 9 8 10 DIN1 DIN2 DIN3 I O GROUND DIN4 DIN6 COMMON EXTERNAL FAULT RUN ENABLE OUTPUT FREQUENCY DIN1 DIN3 COMMON START PULSE STOP PULSE FAULT RESET Vin 2 5 6 7 24...

Page 7: ...utton for 5 secs to enable it Accel Time 1 30 s Decel Time 1 30 s Current Limit Nameplate Volt 460 V 60 00 Hz Power Factor Loc Ctrl Place Keypad Input Phase Supv 0 No Response Repeat Setup No Yes Rem...

Page 8: ...z V7 2 Frequency Reference 0 00 Hz G1 x G6 1 Slot A Board G6 5 Slot E Board O1 Output Frequency 0 0 Hz O2 Freq Reference 0 0 Hz Ox M7 1x Multimonitor Menu Navigation Up Arrow The up arrow advances to...

Page 9: ...menus depress the ENTER button for 2 seconds While in the other menus if there is no keypad activity the display will return to the Operate Menu after 30 seconds Code Signal Name Unit Description O 1...

Page 10: ...rd has been completed the following parameters need to be verified or adjusted as necessary to properly set up the software for the application Parameter Number Parameter Name Desired Setting P1 1 1 M...

Page 11: ...c 0 6 0 300 DIN1 DIN2 0 1 2 3 4 5 6 Start fwd Start Stop Start Stop Start pulse Fwd 2 Start 2 Stop Start 2 Stop Start rvs Rvs Fwd Run enable Stop pulse Rvs 2 Rvs Fwd Run enable P1 2 2 1 DIN3 function...

Page 12: ...44 Device change different type 7 Saturation trip 26 Startup prevented 45 Device added different type 8 System fault 29 Thermistor fault 50 Analog input Iin 4 mA for the signal range 4 to 20 mA 9 Unde...

Page 13: ...e new item Press the ENTER key to accept the change Code Signal Name Unit Description V7 1 Output Frequency Hz Output frequency V7 2 Frequency reference Hz Frequency reference setting V7 3 Motor speed...

Page 14: ...the right solution for the application But decision makers demand more than just innovative products They turn to Eaton for an unwavering commitment to personal support that makes customer success a t...

Reviews: