background image

INS #

Installation Instructions

Model # CKT16
Model # CKT32
Model # CKT48

Serial Enclosure (CKT)

Boîtier série (CKT)

Alojamiento Serial (CKT)

General Information 

The Serial Enclosure is packaged separately from the 

ControlKeeper TouchScreen Logic Board to protect 

components during shipping. This installation instruction 

pertains to the installation of the enclosure for this unit. 

Please refer to the ControlKeeper T installation instruction 

included in the box with the ControlKeeper Logic Board 

for information specific to the logic board installation.
The ControlKeeper T enclosure is available in three 

different sizes: 16 size, 32 size and 48 size. It can be 

configured with different relay types as needed to achieve 

your lighting needs.

Getting Started

1.  Do not discard these installation instructions. Please 

keep for future reference and operation information.

2.  The relays and center rail are protected by shrink-

wrap. Leave shrink-wrap in place until all drilling and 

metal work is complete to protect against metal 

shards getting into component circuitry. 

3.  Always disconnect all power before wiring.
4.  Use only as intended and at the listed voltage.
5.  All installation service must be performed by qualified 

personnel or service technicians.

6.  Install in accordance with National Electrical Code 

and any other codes that may apply.

7.  High voltage is present inside the lighting enclosure. 

Use extreme caution when performing maintenance 

on this equipment. Failure to follow this warning and 

proper safety procedures could result in severe injury 

or death and/or damage to the equipment.

8.  Document all wiring that is terminated to the relays 

so that the lighting control equipment can be properly 

configured and programmed for operation.

Mounting the Enclosure

1.  If the enclosure is a 32 or 48 size, remove the upper 

backplate from the enclosure by using the 1/4 turn 

screws provided. The proper operation of these 

screws is to push in gently and turn 1/4 turn left until 

the screw head is horizontal to release the catch 

mechanism. Turning these screws more than 1/4 turn 

may cause them to break.

2.  Choose a dry location convenient to the circuit 

breaker panel.

3.  Mount the panel on a firm surface using pre-drilled 

holes.

4.  Connect the enclosure to the circuit breaker panel 

using conduit. The conduit punch hole can not exceed 

3 inches from the back of the enclosure. If this 

measurement is exceeded, the logic board will not fit 

properly inside the enclosure.

5.  Remove all cuttings and dirt before removing shrink-

wrap from the relays and center rails.

Note:

N

Make certain that high voltage and low voltage 

wiring enters the enclosure separately. High 

voltage wiring should not be brought into the 

enclosure through the bottom or bottom left corner 

of the enclosure. 

Low voltage wiring can be brought into the enclosure 

from the bottom or bottom left of the enclosure. If low 

voltage wire must be brought into the cabinet from the 

top section, there is a knockout reserved on the left side 

which will allow conduit to be run from the top of the 

enclosure into the low voltage wiring area. Failure to 

separate high voltage from low voltage wiring may cause 

interference with logic board function.

Summary of Contents for CKT16

Page 1: ...safety procedures could result in severe injury or death and or damage to the equipment 8 Document all wiring that is terminated to the relays so that the lighting control equipment can be properly co...

Page 2: ...Two Pole Relay Card and the Serial Latching Relay Card Please refer to the specific section for your relay card type that you are wiring For all relay types 1 Verify that all wire cuttings are remove...

Page 3: ...down relay terminal screws Manufacturer s recommended torque rating is 18 lb in 1 475 foot lbs 2 0 Nm 4 Document relay to circuit information for future reference To Lighting Load From Branch Circuit...

Page 4: ...ay result in it breaking Manually Controlling Relays The relays in the ControlKeeper T enclosure may be controlled before the logic board is in place using the Relay Stack Controller or the individual...

Page 5: ...ge wiring must enter the cabinet from the lower left side of the enclosure or be piped through the high voltage section in conduit using the special knockouts reserved for this section 3 All low volta...

Page 6: ...gateway called the GDS I GDS stations are wired using the Eaton s Cooper LCCP or LCCNP cable or Belden 1502P or 1502R equivallents See the ControlKeeper T logic board installation instructions for fur...

Page 7: ...de des vis 1 4 incluses Pour obtenir le fonctionnement correct des vis vous devez les pousser d licatement et effectuer de tour vers la gauche jusqu ce que la t te de la vis soit dans la position hori...

Page 8: ...r usage avec une charge un seul p le Le branchement des deux circuits charges bipolaires la carte de relais standard annulera la garantie de l quipement et peut entra ner des blessures s rieuses ou la...

Page 9: ...informations concernant le branchement du relais au circuit pour une r f rence ult rieure C blage des relais C ble 6 AWG max Classification du relais 20A 208 240 480V Vers la charge d clairage 1 Vers...

Page 10: ...ur neutralise le relais qui attend alors la prochaine commande en provenance du ControlKeeper L interrupteur basculant trois positions du RSC permet de neutraliser l interrupteur prioritaire de relais...

Page 11: ...le c blage basse tension doit tre achemin dans un tuyau s par du c blage de tension de ligne 4 Utilisez un c ble 18 AWG torsad sans isolant pour tout c blage de dispositif de fermeture basse tension...

Page 12: ...Keeper T pour en savoir plus au sujet de cette mise terre Mise terre de la carte logique Conformit UL 924 Avec l ajout de l accessoire du module de relais interface le syst me de contr le d clairage a...

Page 13: ...nfigurar correctamente el equipo de control de iluminaci n y poder programarlo para su funcionamiento Montaje del alojamiento 1 Si se est utilizando un alojamiento de tama o 32 o 48 extraiga la placa...

Page 14: ...te la pel cula protectora termorretr ctil de las tarjetas de rel luego de haber quitado los fragmentos de cables del alojamiento 3 Pruebe los circuitos de rama para corroborar que no se produzcan cort...

Page 15: ...as caracter sticas nominales del rel de dos polos son de 208 240 y 480 voltios y 20 amperios como m ximo 2 Los bloques de terminales del rel tienen un l mite m ximo de cable de 6 AWG 3 Los rel s de do...

Page 16: ...cada rel Controlador del bloque del rel El Controlador del bloque del rel RSC se encuentra en la parte inferior del alojamiento Funciona como un dispositivo de anulaci n maestro en el sistema El RSC...

Page 17: ...lmente reservados para esa secci n 3 Todos los cables de bajo voltaje deben pasarse por el conducto separado de los cables de voltaje de l nea 4 Pruebe todos los cables de la red para verificar que no...

Page 18: ...T a trav s de una puerta de enlace llamada GDS I Las estaciones GDS se cablean por medio del cable Eaton s Cooper LCCP o LCCNP o de sus equivalentes Belden 1502P o 1502R Consulte las instrucciones de...

Page 19: ......

Page 20: ...b www coopercontrol com para conocer nuestros t rminos y condiciones 2018 Eaton All Rights Reserved Printed in USA Publication No IL503028EN March 1 2018 Eaton 1121 Highway 74 South Peachtree City GA...

Reviews: