background image

i-on Series 

Security System 

Administration and User Manual 

for i-on Compact, i-on30R+, i-on40H+, i-onG2SM and i-onG3MM

 

 

Issue 3 

Control unit software version 6.00.xx 

Summary of Contents for i-on Series

Page 1: ...i on Series Security System Administration and User Manual for i on Compact i on30R i on40H i onG2SM and i onG3MM Issue 3 Control unit software version 6 00 xx...

Page 2: ...ential damage or loss whatsoever including but not limited to damage or loss of use of equipment plant or power system cost of capital loss of power additional expenses in the use of existing power fa...

Page 3: ...he set unset status from a two way remote control 14 Starting a Hold Up Alarm HUA from a two way remote control 14 Using a one way remote control 14 Setting from a one way remote control 15 Unsetting...

Page 4: ...nd sounders 37 Testing a wired keypad 38 Testing the on board keypad 39 Performing a walk test 39 Testing outputs 41 Testing remote controls 42 Testing user HUAs 42 Testing proximity tags 43 Testing A...

Page 5: ...ther publications If you are new to i on alarm systems you should read one of the following guides first i on Compact User Guide i on Series User Guide for i on30R i on40H i onG2SM and i onG3MM These...

Page 6: ...configured as a partitioned not part setting system Please refer to page 5 for a description of part setting and partitioned modes The available user types are as follows Master user This user is able...

Page 7: ...ntrol unit can for example notify the Alarm Receiving Centre ARC A duress code has no access to the user menu and cannot have a remote control or proximity reader tag Note The Installer must program y...

Page 8: ...A remote password is automatically generated and displayed when you create this user which the third party system requires Level 4 This type of user can be created only by the installer and is able to...

Page 9: ...tely e g using the web interface Depending on how your installer has programmed the system you may receive a phone call from the installer to request access About part setting and partitioned modes De...

Page 10: ...arate alarm systems A zone is armed only when ALL of the partitions that it belongs to are set If you unset any of the partitions that a zone belongs to the control unit will unset that zone This allo...

Page 11: ...oke detectors flood sensors Hold Up Alarm buttons or emergency exits Monitors for machinery for example freezers or other type of technical alarm Using a keypad to set or unset the system This section...

Page 12: ...Partitions partitioned system only To choose the partition s to set and whether to full set or part set those partitions Note Please refer to page 5 for details of partitions 4 If you selected Partit...

Page 13: ...you have the final exit door open or you trigger one of the detectors on your entry exit route the keypad gives an interrupted setting tone this is normal The system sets when one of the following occ...

Page 14: ...n strobe unit when the system sets If the system does not set If the system does not set check the display to see if any zone is active Normally the system can set only when zones other than those in...

Page 15: ...s you used to leave the premises Do not stray from this route you may cause an alarm 2 Depending on how the system is configured you may hear an entry tone If you hear the tone go directly to the keyp...

Page 16: ...te a User Defined output Each remote control has a unique electronic identity and is assigned page 31 to a specific user The remote control is designed to provide feedback about the current status of...

Page 17: ...ult for example a zone is active all four LEDs glow red for three seconds 3 You will hear a continuous exit tone unless the system is configured for silent or instant setting The system sets as descri...

Page 18: ...two way remote control 1 Press and hold any two diagonally opposite buttons at the same time All four LEDs flash red three times 2 The control unit starts a hold up alarm and if applicable sends the a...

Page 19: ...ion for key A is to full set all of the user s partitions Keys can be configured to part set specified partitions if required 3 You will hear a continuous exit tone unless the system is configured for...

Page 20: ...play and can only transmit to the control unit it cannot receive information back from the control unit Figure 4 One way radio keypad The keypad cannot show the status of the system The left hand Tran...

Page 21: ...ll have limited time to unset the system before it generates an alarm 3 Enter your access code or present your proximity tag to the keypad 4 Press Using a two way KEY RAS keypad Note Please refer to t...

Page 22: ...configured you may hear an entry tone If you hear the tone go directly to the keypad since you will have limited time to unset the system before it generates an alarm 2 Within the allocated time key...

Page 23: ...failure of a communications link from the control unit When an alarm occurs the control unit normally activates internal sounders and depending on severity external siren strobe units Table 1 shows t...

Page 24: ...t beeping once per second from internal sounders A system fault detected by the control unit such as a mains failure or communications line fault This is known as an alert see page 24 Other alarm acti...

Page 25: ...ble are as shown in Table 2 Table 2 Speech message acknowledgement Function Key End this call and let the control unit contact the other nominated persons for this alarm 5 Play message again 3 Clear d...

Page 26: ...arm For example OR for example The bottom line alternates once a second to show the name of the zone or device that generated the alarm For example 4 Press to indicate that you have acknowledged the a...

Page 27: ...ed you will see a message similar to the following while acknowledging an alarm 1 Note down the 4 digit number 4321 in this example 2 Press to clear the message The display returns to normal 3 Call th...

Page 28: ...t 1 Press before entering your access code 2 Enter your access code or present your proximity tag to the keypad The bottom line displays the most recent alert For example OR for example The bottom lin...

Page 29: ...rmal Partition Guard Set Only BMS Duress Easy Set Shunt Level 4 Omit Zones Shunt Group not i on Compact Users Add User Edit User Name Type not U001 Partitions partitioned system Code Prox Tag Remote H...

Page 30: ...ot i on Compact Add Event Edit Event Event name Event time Event day Ward Partitions Warning time Warning tone Delete event Add Exception Edit Exception Exception Name Exception Start Time Exception S...

Page 31: ...veral times Entering text You can use the numeric 1 9 and keys see Figure 6 to enter numbers and text Press a key one or more times to obtain the letter you require For example to enter a B press the...

Page 32: ...omitted you have to omit the zone again before you next set the system Alternatively use shunt groups see the next section Note You can omit only those zones that the installer has given the Omittable...

Page 33: ...rd that information A zone can be in more than one shunt group Once the shunt groups are defined there are three ways of shunting them a Master and admin users can use the Shunt Groups option to shunt...

Page 34: ...ew there is only one user the default master user who has full access to perform any action that a user is able to do and access all user options The master user can add new users and while doing so s...

Page 35: ...ly a proximity tag duress and BMS users can have none of these devices If you do not wish to assign these devices most user types can assign the devices to themselves at a later date using the Users o...

Page 36: ...nd BMS users Present an unallocated tag to the keypad until you see Prox Tag added or if you do not want to assign one Note If you have a proximity tag that is already allocated you can find out who i...

Page 37: ...o select the shunt group to assign to the user The indicates the currently selected shunt group 10 The control unit confirms that the user has been added Editing users Editing another user s details T...

Page 38: ...e 25 shows the user types that have access to Users menu and the options available You can depending on your user type Change your own access code Add or delete your own proximity tag remote control o...

Page 39: ...ld Up Alarm To add or delete your own HUA transmitter Remote Password To set the remote password for a BMS or level 4 user App access To enable or disable use of the SecureConnect mobile app 3 Follow...

Page 40: ...in the above example as described in the next section 2 If applicable press to see a more detailed description of the event such as the user name rather than user number associated with the event If y...

Page 41: ...ystem A master or admin user can use the Test option to test various components of the system and to check the current owner of a proximity tag remote control or HUA transmitter Testing sirens and sou...

Page 42: ...are currently using you cannot test a keypad remotely To carry out the test 1 Select Test Wired Keypad The bottom line of the display shows the keypad name and bus address For example All four ABCD L...

Page 43: ...ny other key to test it The display should confirm the key you pressed 5 Press to finish the test Performing a walk test Master and admin users can use Test Walk Test to test detectors without startin...

Page 44: ...ts you select one or more individual zones and test only those zones Press or to scroll up and down the list of zones Press to display Yes at the end of the bottom line to mark the zone as one you wan...

Page 45: ...in a list of any user defined outputs allocated for your use For example The top line shows the address and type of the output In the above example the address is PAN 01 and the type is W wired The o...

Page 46: ...is allocated to The bottom line shows the function of the button and the strength of the signal If the signal strength is less than 4 contact your installer 3 Repeat step 2 for the other buttons Note...

Page 47: ...o end the test Testing proximity tags Master and admin users can use Test Prox Tags to test proximity reader tags To carry out the test 1 Select Test Prox Tags The following is displayed 2 Hold the pr...

Page 48: ...nstaller has configured communications the second line may be used if the first fails to connect 3 Press to start the test The keypad shows the progress of the call Check with the ARC that the test ca...

Page 49: ...firmware and language files at the control unit automatically or using the web interface b Log into the user menu or web interface and change the level 4 user name and code The level 4 user cannot per...

Page 50: ...ion first and another event to set the system partition to a different part set level For example if event 01 part sets the system or a partition do not program event 02 to full set the system Instead...

Page 51: ...you want the event to occur Press or to scroll through each day of the week Press or to specify Yes or No Event Actions In a partitioned system press or to scroll through each partition and or to sel...

Page 52: ...parts of an event Delete Event Use System Config Calendar Set Delete Event to delete an event Add Exception Use System Config Calendar Set Add Exception to create an exception During the time specifi...

Page 53: ...allocated to a single partition that partition may start setting immediately If a user defers a setting event the control unit halts the warning timer and defers setting 30 minutes from the start of t...

Page 54: ...by to select the recipient you want to edit 3 Press or followed by to select one of the following options Name Select this to edit the name of the recipient See page 27 for details of how to enter tex...

Page 55: ...by On Time see below When set to Yes the output changes state every time a user operates the output or according to a schedule if you specify On Time Off Time and Days see below On Time Off Time Days...

Page 56: ...or all remote controls to unset the system HUA Function Enables or disables the ability for remote controls to generate Hold Up Alarms HUAs These options are described next Editing the programming of...

Page 57: ...ig Remotes Edit The following is displayed 2 EITHER a Press the button on the remote control you want to re program Hold down the button until you see the transmit LED flash OR if you do not have the...

Page 58: ...system Unsets selected partitions that the user belongs to After selecting this option use or to scroll through the partitions and use or to choose whether the partition should be unset by the button...

Page 59: ...n it to another user The System Config Remotes menu provides two options for deleting remote controls Delete This allows you to delete a specific remote control see below Delete All This deletes all r...

Page 60: ...nable this feature by configuring Basic confirmation mode Doing so means that the system does not comply with BS8243 or DD243 After selecting HUA Function use or to select Enabled or Disabled followed...

Page 61: ...Whether the control unit is in partitioned or part setting mode if applicable Cloud This gives information about the connection to the SecureConnect Expanders Not available for i on Compact For each...

Page 62: ...code for the SecureConnect app The app allows you to monitor and control your alarm system over the internet from your mobile phone or tablet The pairing code uniquely pairs your app with your panel...

Page 63: ...ect is a trademark of Eaton www touchpoint online com Product Support UK Tel 44 0 1594 541978 Available between 08 30 to 17 00 Monday to Friday email securitytechsupport eaton com Part Number 13392068...