Questions?/Des questions?/¿Preguntas? 1-800-334-6871 ConsumerProducts@eaton.com
1
PACKAGING CONTENTS/CONTENU DE L’EMBALLAGE/CONTENIDO DEL PAQUETE
Instruction Manual/Manuel d’instructions/Instrucciones
Lumark
FOR BEST RESULTS
• Install light 10-15 feet above the ground.
• Do not mount fixture close to reflective surfaces
such as windows, white walls, white surfaces
and water.
• When installing two fixtures on one switch,
make sure the switch is rated for at least a
1 A inductive load.
• When mounting coverplate, make sure the photo
sensor orientation is at the bottom.
• When mounting to a wall, make sure the fixture is
7 in. on center away from eave and 13 inches on
center away from inside corner of the exterior
wall (Fig. 1).
MOUNTING AND WIRING YOUR FIXTURE
WARNING: Risk of electric shock. Disconnect
power at fuse or circuit breaker before installing
or servicing.
NOTE:
Fixture can be wall or eave mounted (Fig. 2)
to recessed mounted standard junction boxes (Fig. 3)
without the use of the Adaptor Kit (H). Junction box must
be at least 1-1/2 inch in depth for proper installation for
recessed mount application.
NOTE:
For installation using surface mount junction
boxes and conduit, see Adaptor Kit installation
instructions.
1.
Line up the holes on the mounting bracket (B) with
the holes on your junction box. Using either (2) #6
screws or (2) #8 screws (D) (depending on size of
the holes in your junction box), attach the mounting
bracket (B) to your junction box (Fig. 4).
ITEMS REQUIRED
(Purchase separately)
• Phillips screwdriver
• Weatherproof silicone caulk
IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:
• Heed all warnings, including below warnings AND those included on product.
• Save these instructions and warnings.
• For outdoor use only.
• cULus LISTED for wet location.
• Disassembling your fixture will void the warranty.
• Your fixture is prewired and preassembled for easy installation.
• Read and follow these instructions.
• Risk of fire/electric shock. If not qualified, consult an electrician.
• Disconnect power at fuse or circuit breaker before installing or servicing.
CAUTION
• Connect fixture to a 120V, 60 Hz power source. Any other connection voids
the warranty.
• Fixture should be installed by persons with experience in household wiring or by a
qualified electrician. The electrical system, and the method of electrically connecting
the fixture to it, must be in accordance with the National Electrical Code and local
building codes.
• This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause
undesired operation.
WARNING: FCC Regulations state that any unauthorized changes or
modifications to this equipment not expressly approved by the manufacturer
could void the user’s authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.
LFS1L30WPCI
(White/Blanco)
A.
Light fixture
Accesorio
ENGLISH
D.
(2) #6-32 x 3/4 in. and (2) #8-32 x 3/4 in. junction box screws
(use the size that fits your junction box)
(2) Tornillos #6-32 x 3/4 pulg. y (2) tornillos #8-32 x 3/4 pulg.
para montaje de la caja de conexión
(utilice el tamaño que mejor se adecue a su caja de conexión)
C.
Gasket
Junta
G.
(2) Decorative screw cover caps
(2) Cubiertas tapatornillos decorativas
F.
(2) #8-32 x 1-1/4 in. cover
mounting screws (pre-attached)
(2) Tornillos #8-32 x 1-1/4 pulg.
de montaje de la cubierta
(préfixé)
WARNING
B.
Mounting bracket
Soporte de montaje
Round
1-1/2 in.
Octagonal
1-1/2 in.
3
2
Wall mount
Eave mount
4
D
B
D
Junction box
7 in.
13 in.
1
13 in.
E.
Support hook
Crochet
LFS1L30BPCI
(Bronze/Bronce)
H.
(1) Adapter Kit
(1) kit d’adaptateur