Instruction Leaflet IL040016EN

PowerXL DG1 Series VFD

EATON

www.eaton.com

1

Effective March 2014
New Information

Instruction Leaflet

ɂɧɫɬɪɭɤɰɢɹ

 

ɩɨ

 

ɦɨɧɬɚɠɭ

Asennusohje

Instrukcja monta

Ī

u

Montageanweisung

Montagehandleiding

Návod k montáži

Navodila za montažo

Notice d’installation

Montagevejledning

Paigaldusjuhend

Návod na montáž

Instrucciones de montaje

ȅįȘȖȓİȢ

 

İȖțĮIJȐıIJĮıȘȢ

Szerelési utasítás

Ɇɨɧɬɚɠɧɢ

 

ɢɧɫɬɪɭɤɰɢɢ

Istruzioni per il montaggio

Instruções de montagem

Mont

Ɨ

žas instrukcija

Instruc

Ġ

iuni de montaj

ᆹ㻵䈤᰾

Monteringsanvisning

Montavimo instrukcija

Electric Current! Danger to Life!

Only skilled or instructed persons may carry out the following operations. 

Lebensgefahr durch elektrischen Strom!

Nur Elektrofachkräfte und elektrotechnisch unterwiesene Personen 
dürfen die im Folgenden beschriebenen Arbeiten ausführen.

Tension électrique dangereuse !

Seules les personnes qualifiées et averties doivent exécuter les 
travaux ci-après.

¡Corriente eléctrica! ¡Peligro de muerte!

El trabajo a continuación descrito debe ser realizado por personas 
cualificadas y advertidas.

Tensione elettrica: Pericolo di morte!

Solo persone abilitate e qualificate possono eseguire le operazioni di 
seguito riportate.

 

䀖⭥ড䲙ʽ

ਚݱ䇨уъӪઈ઼ਇ䗷уъ䇝㓳ⲴӪઈ䘋㹼

 

лࡇᐕ֌DŽ

ɗɥɟɤɬɪɢɱɟɫɤɢɣ

 

ɬɨɤ

Ɉɩɚɫɧɨ

 

ɞɥɹ

 

ɠɢɡɧɢ

!

Ɍɨɥɶɤɨ

 

ɫɩɟɰɢɚɥɢɫɬɵ

 

ɢɥɢ

 

ɩɪɨɢɧɫɬɪɭɤɬɢɪɨɜɚɧɧɵɟ

 

ɥɢɰɚ

 

ɦɨɝɭɬ

 

ɜɵɩɨɥɧɹɬɶ

 

ɫɥɟɞɭɸɳɢɟ

 

ɨɩɟɪɚɰɢɢ

.

Levensgevaar door elektrische stroom! 

Uitsluitelijk deskundigen in elektriciteit en elektrotechnisch 
geinstrueerde personen is het toegestaan, de navolgend 
beschrevene werkzaamheden uit te voeren.

Livsfare på grund af elektrisk strøm!

Kun uddannede el-installatører og personer der e instruerede i 
elektrotekniske arbejdsopgaver, må udføre de nedenfor anførte 
arbejder.

ȆȡȠıȠȤȒ

țȓȞįȣȞȠȢ

 

ȘȜİțIJȡȠʌȜȘȟȓĮȢ

!

ȅȚ

 

İȡȖĮıȓİȢ

 

ʌȠȣ

 

ĮȞĮijȑȡȠȞIJĮȚ

 

ıIJȘ

 

ıȣȞȑȤİȚĮ

 

șĮ

 

ʌȡȑʌİȚ

 

ȞĮ

 

İțIJİȜȠȪȞIJĮȚ

 

ȝȩȞȠ

 

Įʌȩ

 

ȘȜİțIJȡȠȜȩȖȠȣȢ

 

țĮȚ

 

ȘȜİțIJȡȠIJİȤȞȓIJİȢ

.

Perigo de vida devido a corrente eléctrica!

Apenas electricistas e pessoas com formação electrotécnica podem 
executar os trabalhos que a seguir se descrevem.

Livsfara genom elektrisk ström!

Endast utbildade elektriker och personer som undervisats i 
elektroteknik får utföra de arbeten som beskrivs nedan.

Hengenvaarallinen jännite! 

Vain pätevät sähköasentajat ja opastusta saaneet henkilöt saavat 
suorittaa seuraavat työt.

en

de

fr

es

it

zh

ru

nl

da

el

pt

sv

fi

Summary of Contents for PowerXL DG1 Series VFD

Page 1: ...nte el ctrica Peligro de muerte El trabajo a continuaci n descrito debe ser realizado por personas cualificadas y advertidas Tensione elettrica Pericolo di morte Solo persone abilitate e qualificate p...

Page 2: ...rsonas Pavojus gyvybei d l elektros srov s Tik elektrikai ir elektrotechnikos specialistai gali atlikti emiau apra ytus darbus Pora enie pr dem elektrycznym stanowi zagro enie dla ycia Opisane poni ej...

Page 3: ...1 hp 3D3 3 3A 1 1 kW 1 5 hp 4D3 4 3A 1 5 kW 2 hp 5D6 5 6A 2 2 kW 3 hp 7D6 7 6A 3 kW 5 hp 9D0 9A 4 kW 7 5 hp VT 012 12A 5 5 kW 7 5 hp 016 16A 7 5 kW 10 hp 023 23A 11 kW 15 hp 031 31A 15 kW 20 hp 038 3...

Page 4: ...2 3 7 6 575 Vac 1 2 5 1 5 3 7 3 3 7 5 FR2 230 Vac 5 7 5 3 5 5 12 5 25 9 63 244 7 16 50 419 1 15 98 405 9 14 96 380 0 6 61 167 8 5 28 134 1 3 54 90 0 3 54 90 0 0 28 7 0 23 37 10 6 480 Vac 7 5 15 5 5 11...

Page 5: ...equired CFM m3 h FR1 230 Vac 0 75 3 0 55 2 2 3 7 11 0 79 20 0 79 20 3 94 100 1 97 50 22 38 480 Vac 1 5 0 75 3 7 2 2 7 6 575 Vac 3 2 5 1 5 3 7 3 3 7 5 FR2 230 Vac 4 7 5 3 5 5 12 5 25 1 18 30 1 18 30 6...

Page 6: ...rch 2014 6 EATON www eaton com PowerXL DG1 Series VFD FR1 Mounting Instructions Step 1 Step 2 FR2 Mounting Instructions Step 1 Step 2 Screw Four M5x15 or 3 16 inch Nut Four M5 or 3 16 inch Screw Four...

Page 7: ...March 2014 PowerXL DG1 Series VFD EATON www eaton com 7 FR3 Mounting Instructions Step 1 Step 2 FR4 Mounting Instructions Step 1 Step 2 Screw Four M6x15 or 1 4 inch Nut Four M6 or 1 4 inch Screw Four...

Page 8: ...struction Leaflet IL040016EN Effective March 2014 8 EATON www eaton com PowerXL DG1 Series VFD FR5 Mounting Instructions Step 1 Step 2 Step 3 Step 4 Screw Four M8x20 or 3 8 inch Nut Four M8 or 3 8 inc...

Page 9: ...roitus Kytke vain j nnitteett m ss tilassa Varov n P ipojujte jen p i zcela odpojen m nap jen Hoiatus hendada ainult pingevabas olekus Figyelmeztet s Csak fesz lts gmentes llapotban csatlakoztassa Br...

Page 10: ...IL040016EN Effective March 2014 10 EATON www eaton com PowerXL DG1 Series VFD Rubber Grommet Installation Instructions Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 D1 Cable D2 Grommet D1 D2 D1 2 mm Self...

Page 11: ...480 Vac 7 5 15 5 5 11 12 23 575 Vac 1 7 5 15 5 5 11 10 18 FR3 230 Vac 10 15 7 5 11 31 48 0 59 15 1 57 40 0 59 15 1 97 50 0 59 15 1 57 40 0 59 15 1 97 50 480 Vac 20 30 15 22 31 46 575 Vac 1 20 30 15 22...

Page 12: ...VT IL at 40 C Fuse Rating Class T NEC Wire Size AWG Terminal Connection Size AWG Line and Motor Ground Line and Motor Ground FR1 3D7 3 2 4 4 4 2 4 6 3 7 4 8 10 14 14 24 10 18 10 4D8 4 4 6 1 6 0 6 6 4...

Page 13: ...IH 208V Input Current VT IL Current CT IH at 50 C Current VT IL at 40 C Fuse Rating gG gL Mains and Motor Cable Cu mm2 Terminal Cable Size Main Terminal Cu mm2 Earth Terminal Cu mm2 FR1 3D7 3 2 4 4 3...

Page 14: ...Class T NEC Wire Size AWG Terminal Connection Size AWG Line and Motor Ground Line and Motor Ground FR1 2D2 2 0 3 1 3 0 2 1 3 0 10 14 14 30 10 18 10 3D3 3 1 4 3 4 3 0 3 4 10 14 14 30 10 18 10 4D3 4 0...

Page 15: ...Input Current CT IH 400V Input Current VT IL Current CT IH at 50 C Current VT IL at 40 C Fuse Rating gG gL Mains and Motor Cable Cu mm2 Terminal Cable Size Main Terminal Cu mm2 Earth Terminal Cu mm2...

Page 16: ...Instruction Leaflet IL040016EN Effective March 2014 16 EATON www eaton com PowerXL DG1 Series VFD...

Page 17: ...Board Battery Standard RJ45 EtherNet IP BACnet IP Modbus TCP Optional Card A Optional Card B RS 485 Terminating Resistor Removable MOV Screw Motor Ground Clamp Location Grounding Strap Location Groun...

Page 18: ...Control voltage output 100 mA max 16 GND I O Signal Ground I O Ground for Reference and Control 17 AO1 Analog Output 1 Output Frequency Shows Output frequency to motor 0 60 Hz 4 mA to 20 mA 18 AO2 Ana...

Page 19: ...2 2 2 0 10V 4 20mA B0 B1 10 Vdc 4 20mA 0 10V 2 I O 1 2 VFD VFD I O 100mA 100mA I O 0 60Hz 4 20mA 0 FLA 4 20mA Modbus BACnet Modbus BACnet 3 VFD 1 VFD 3 VFD 2 VFD 1 10V 2 AI1 3 AI1 4 AI2 5 AI2 6 GND 7...

Page 20: ...Instruction Leaflet IL040016EN Effective March 2014 20 EATON www eaton com PowerXL DG1 Series VFD...

Page 21: ...kun tages i anvendelse hvis det konstateres at maskinen opfylder beskyttelseskravene i maskindirektivet 89 392 E F EMC korrekt installation Tr k styre og netledninger rumligt adskilt fra motorledning...

Page 22: ...krmiljenih naprav in njihovega pribora dovoljen le tedaj ko je bilo ugotovljeno da stroj ustreza varnostnim zagtevam Direktive o strojih 89 392 EGS Monta a v skladu z EMZ Krmilne in omre ne vodnike na...

Page 23: ...ring connections must be made by a UL listed and CSA certified ring lug terminal connector sized for the wire gauge being used The connector must be fixed using the crimping tool specified by the conn...

Page 24: ...Series VFD Eaton is a registered trademark All other trademarks are property of their respective owners Eaton 1000 Eaton Boulevard Cleveland OH 44122 United States Eaton com 2014 Eaton All Rights Rese...

Reviews: