background image

Part Number

  

 

 

 

Operating Instructions 

 

Item no. LS-128.

 

Revision 002

 

Release 17/02/2016

 

Page 1 of 8

 

 

 
ebm-papst A&NZ Pty Ltd

 

10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464 

ABN 33 115 927 556 

NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246 

 

sales@ebmpapst.com.au · www.ebmpapst.com.au 

 

EBM ALPHA 

ebm-papst A&NZ Pty Ltd 

10 Oxford Road 

Laverton North VIC 3026 

Australia 

Phone: +61 3 9360 6400 

Fax: +61 3 9360 6464 

sales@ebmpapst.com.au

 

www.ebmpapst.com.au

 

 

CONTENTS 

1.

 

SAFETY REGULATIONS AND NOTES ......................... 1

 

1.1

 

Levels of hazard warnings .............................................. 1

 

1.2

 

Staff qualification ........................................................... 1

 

1.3

 

Basic safety rules........................................................... 1

 

1.4

 

Electrical voltage............................................................ 1

 

1.5

 

Mechanical movement ................................................... 2

 

1.6

 

Hot surface .................................................................... 2

 

1.7

 

Transport ....................................................................... 2

 

1.8

 

Storage ......................................................................... 2

 

1.9

 

Disposal ........................................................................ 2

 

2.

 

PROPER USE ............................................................... 3

 

3.

 

TECHNICAL DATA ....................................................... 4

 

3.1

 

Product drawing ............................................................. 4

 

3.2

 

Nominal data ................................................................. 5

 

3.3

 

Technical features ......................................................... 5

 

3.4

 

Mounting data ................................................................ 5

 

3.5

 

Transport and storage conditions ................................... 5

 

4.

 

CONNECTION AND START-UP .................................... 6

 

4.1

 

Connecting the mechanical system ................................ 6

 

4.2

 

Connecting the electrical system .................................... 6

 

4.2.1

 

Prerequisites .................................................... 6

 

4.2.2

 

Voltage control ................................................. 6

 

4.2.3

 

Frequency converter ......................................... 6

 

4.3

 

Connection of the terminal ............................................. 6

 

4.4

 

Connection Screen ........................................................ 7

 

4.5

 

Checking the connections .............................................. 7

 

4.6

 

Switch on device ............................................................ 7

 

4.7

 

Switching off the device ................................................. 7

 

5.

 

MAINTENANCE, MALFUNCTIONS, POSSIBLE 
CAUSES AND REMEDIES ............................................ 7

 

5.1

 

Cleaning ........................................................................ 8

 

5.2

 

Safety test ..................................................................... 8

 

 

1.

 

SAFETY REGULATIONS AND NOTES 

Please read these operating instructions carefully before starting 

to work with the device. Observe the following warnings to 

prevent malfunctions or physical damage to both property and 

people. 

These operating instructions are to be regarded as part of this 
device. If the device is sold or transferred, the operating 

instructions must accompany it. 

These operating instructions may be duplicated and forwarded 

for information about potential dangers and their prevention. 

1.1

 

Levels of hazard warnings

 

These operating instructions use the following hazard levels to 

indicate potentially hazardous situations and important safety 

regulations: 

DANGER 

Indicates an imminently hazardous situation which, if 

not avoided, will result in death or serious injury. 
Compliance with the measures is mandatory. 

WARNING 

Indicates a potentially hazardous situation which, if 

not avoided, could result in death or serious injury. 

Exercise extreme caution while working. 

CAUTION 

Indicates a potentially hazardous situation which, if 

not avoided,may result in minor or moderate injury or 

damage of property. 

NOTE 

A potentially harmful situation can occur and, if not 

avoided, can lead to property damage. 

1.2

 

Staff qualification

 

The device may only be transported, unpacked, installed, 

operated, maintained and otherwise used by qualified, trained 

and authorised technical staff. 

Only authorised specialists are permitted to install the device, to 

carry out a test run and to perform work on the electrical 

installation. 

1.3

 

Basic safety rules 

Any safety hazards stemming from the device must be re-

evaluated once it is installed in the end device. 

Observe the following when working on the unit: 

 

Do not make any modifications, additions or conversions to 

the device without the approval of ebm-papst A&NZ. 

1.4

 

Electrical voltage 

 

Check the electrical equipment of the device at regular 

intervals, refer to chapter 5.2 Safety test. 

 

Replace loose connections and defective cables 

immediately. 

 

DANGER 

 

Electrical load on the device 

Risk of electric shock 

 

Stand on a rubber mat if you are working on an 
electrically charged device. 

 

Summary of Contents for ALPHA

Page 1: ...device If the device is sold or transferred the operating instructions must accompany it These operating instructions may be duplicated and forwarded for information about potential dangers and their...

Page 2: ...Rotating device Body parts that come into contact with the rotor can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a s...

Page 3: ...this product is installed Proper use also includes Using the device in accordance with the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter 3 2 Nominal data...

Page 4: ...3 9360 6464 ABN 33 115 927 556 NSW Phone 61 02 9827 6400 NSW Fax 61 02 9827 6464 NZ Phone 64 09 525 0245 NZ Fax 64 09 525 0246 sales ebmpapst com au www ebmpapst com au EBM ALPHA 3 TECHNICAL DATA 3 1...

Page 5: ...type of protection IP 44 depending on installation and position Junction box type of protection Must be stored in a dry environment Insulation class B Humidity class F1 2 Mounting position Any Conden...

Page 6: ...agree with the connection data and the data of the operating capacitor Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed...

Page 7: ...h for the supply line When disconnecting be sure to disconnect the earth wire connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return t...

Page 8: ...r high pressure washer Do not use any cleaners containing acids bases or solvents Do not use any pointed or sharp edged objects to clean 5 2 Safety test What has to be tested How to test Frequency Whi...