background image

Part Number

  

 
 
 

Operating Instructions 

 

Item no. LS-105.

 

Revision 003

 

Release 30/06/2017

 

Page 1 of 12

 

 
 
ebm-papst A&NZ Pty Ltd

 

10 Oxford Road · Laverton North VIC 3026 · Phone +61 (03) 9360 6400 · Fax +61 (03) 9360 6464 

ABN 33 115 927 556 

NSW Phone +61 (02) 9827 6400 · NSW Fax +61 (02) 9827 6464 · NZ Phone +64 (09) 525 0245 · NZ Fax +64 (09) 525 0246 

 

sales@ebmpapst.com.au · www.ebmpapst.com.au 

 

W3G500GN3307-LA1 

ebm-papst A&NZ Pty Ltd 

10 Oxford Road 
Laverton North VIC 3026 
Australia 
Phone: +61 3 9360 6400 
Fax: +61 3 9360 6464 

sales@ebmpapst.com.au

 

www.ebmpapst.com.au 

 

CONTENTS 

1.

 

SAFETY REGULATIONS AND INFORMATION ............. 1

 

1.1

 

Hazard levels for warnings ............................................... 1

 

1.2

 

Staff qualification .............................................................. 1

 

1.3

 

Basic safety rules ............................................................. 1

 

1.4

 

Voltage ............................................................................. 1

 

1.5

 

Safety and protective features .......................................... 2

 

1.6

 

Electromagnetic radiation ................................................. 2

 

1.7

 

Mechanical movement ...................................................... 2

 

1.8

 

Emission ........................................................................... 2

 

1.9

 

Hot surface ....................................................................... 2

 

1.10

 

Transport .......................................................................... 2

 

1.11

 

Storage ............................................................................. 3

 

2.

 

INTENDED USE ............................................................... 3

 

3.

 

TECHNICAL DATA .......................................................... 4

 

3.1

 

Product drawing ................................................................ 4

 

3.2

 

Nominal data .................................................................... 5

 

3.3

 

Technical features ............................................................ 5

 

3.4

 

Mounting data ................................................................... 5

 

3.5

 

Transport and storage conditions ..................................... 5

 

3.6

 

Electromagnetic compatibility ........................................... 5

 

4.

 

CONNECTION AND START-UP ..................................... 6

 

4.1

 

Mechanical system connection ........................................ 6

 

4.2

 

Electrical connection ......................................................... 6

 

4.2.1

 

Requirements ..................................................... 6

 

4.2.2

 

Supply connection and fuses protection ............. 6

 

4.2.3

 

Reactive currents ................................................ 7

 

4.2.4

 

Residual current circuit breaks (RCCB) .............. 7

 

4.2.5

 

Leakage current .................................................. 7

 

4.2.6

 

Locked rotor protection ....................................... 7

 

4.3

 

Connection in terminal box ............................................... 7

 

4.3.1

 

Preparing cables for the connection ................... 7

 

4.3.2

 

Connecting wires with terminals ......................... 8

 

4.3.3

 

Cable routing ...................................................... 8

 

4.4

 

Factory settings ................................................................ 8

 

4.5

 

Connection Screen ........................................................... 9

 

4.6

 

Checking connections .................................................... 10

 

4.7

 

Switch on the device ....................................................... 10

 

4.8

 

Switching off the device .................................................. 10

 

5.

 

INTEGRATED PROTECTIVE FUNCTIONS .................. 10

 

6.

 

MAINTENANCE, MALFUNCTIONS, POSSIBLE 

CAUSES AND REMEDIES ...................................................... 11

 

6.1

 

Cleaning ......................................................................... 11

 

6.2

 

Safety inspection ............................................................ 12

 

6.3

 

Disposal .......................................................................... 12

 

6.3.1

 

Country-specific legal requirements ................. 12

 

6.3.2

 

Disassembly ..................................................... 12

 

6.3.3

 

Component disposal ......................................... 12

 

 

1.

 

SAFETY REGULATIONS AND INFORMATION 

Read these operating instructions carefully before starting work 
on the device. Observe the following warnings to prevent 
malfunctions or danger to persons. 
These operating instructions are to be regarded as part of the 
device. The device is only to be sold or passed on together with 
the operating instructions. 
These operating instructions may be duplicated and distributed 
to inform about potential dangers and their prevention. 

1.1

 

Hazard levels for warnings

 

These operating instructions use the following hazard levels to 
indicate potentially hazardous situations and important safety 
regulations: 

DANGER 

Indicates an imminently hazardous situation which 
will result in death or serious injury if the specified 
actions are not taken. Compliance with the 
instructions is imperative. 

WARNING 

Indicates a potentially hazardous situation which can 
result in death or serious injury if the specified actions 
are not taken. Exercise extreme caution while 
working. 

CAUTION 

Indicates a potentially hazardous situation which can 
result in minor or moderate injury or damage to 
property if the specified actions are not taken. 

NOTE 

A potentially harmful situation can occur and, if not 
avoided, can lead to property damage. 

1.2

 

Staff qualification

 

The device may only be transported, unpacked, installed, 
operated, maintained and otherwise used by suitably qualified, 
trained and authorised staff. 
Only authorised specialists are permitted to install the device, to 
carry out a test run and to perform work on the electrical 
installation. 

1.3

 

Basic safety rules 

The safety hazards associated with the device must be 
assessed again following installation in the final product. 

Note the following when working on the device: 

 

Do not perform any modifications, additions or conversions 
on the device without the approval of ebm-papst A&NZ. 

1.4

 

Voltage 

 

Check the electrical equipment of the device at regular 
intervals, see chapter 6.2 Safety inspection. 

 

Replace loose connections and defective cables 
immediately. 

 

 

Summary of Contents for W3G500GN3307-LA1

Page 1: ...disposal 12 1 SAFETY REGULATIONS AND INFORMATION Read these operating instructions carefully before starting work on the device Observe the following warnings to prevent malfunctions or danger to pers...

Page 2: ...device immediately if you notice a missing or ineffective protective feature 1 6 Electromagnetic radiation Interference from electromagnetic radiation is possible e g in conjunction with open and clos...

Page 3: ...resses that can occur Intended use also includes Use the device in power systems with earthed neutral TN TT power systems only Using the device only in stationary systems Performing all maintenance wo...

Page 4: ...6400 NSW Fax 61 02 9827 6464 NZ Phone 64 09 525 0245 NZ Fax 64 09 525 0246 sales ebmpapst com au www ebmpapst com au W3G500GN3307 LA1 3 TECHNICAL DATA 3 1 Product drawing AIRFLOW DIRECTION All dimensi...

Page 5: ...from the mains Over temperature protected electronics motor Line under voltage phase failure detection Touch current acc IEC 60990 measuring network Fig 4 TN system 3 5 mA Electrical leads Via termina...

Page 6: ...is a built in component and has no electrically isolating switch Only connect the fan to circuits that can be switched off with an all pole separating switch When working on the fan you must switch o...

Page 7: ...D protective devices cannot provide personal safety while operating the device When switching on the power supply of the device pulsed charge currents from the capacitors in the integrated EMC filter...

Page 8: ...s not included in the scope of delivery into the terminal box First connect the PE protective earth Connect the lines to the corresponding terminals Use a screwdriver to do so When connecting ensure...

Page 9: ...A max 250 VAC min 10 mA AC1 KL2 3 NO Floating status contact make for failure KL3 1 OUT Analogue output 0 10 VDC max 3 mA SELV Output of the current motor level 1 V corresponds to 10 level 10 V corres...

Page 10: ...flammable materials are located close to the fan Before switching on check the device for visible external damage and make sure the devices are functional Check the air flow paths of the fan for forei...

Page 11: ...cleaning Motor not turning Mechanical blockage Switch off isolate from supply and remove mechanical blockage Voltage faulty Check mains supply voltage restore power supply Important The error message...

Page 12: ...from the development stage ecological design technical safety and health protection are fixed criteria The following section contains recommendations for ecological disposal of the product and its com...