ECCO STOVE MODEL 730EC2 Manual
SAVE THESE INSTRUCTIONS
TESTED TO: EN13240
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS - SEE NAME PLATE AND INSTRUCTIONS
THIS STOVE MUST BE INSTALLED IN CONJUNCTION WITH THE REQUIREMENTS OF BSEN 15287-1:2007
–
DESIGN INSTALLATION AND COMMISSIONING OF CHIMNEYS.
WARNING NOTE:
Properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional
fumes from de-ashing and re-fuelling may occur. However, persistent fume emission is potentially
dangerous and must not be tolerated. If fume emission does persist, then the following immediate
action should be taken:-
a)
Open doors and windows to ventilate the room and then leave the premises.
b)
Let the fire go out.
c)
Check for flue or chimney blockage and clean if required.
d)
Do not attempt to relight the fire until the cause of the fume emission has been identified and
corrected. If necessary seek expert advice.
The most common cause of fumes emission is flueway or chimney blockage. For your own safety these
must be kept clean at all times.
A CO detector must be fitted in the same room as this appliance to conform to UK requirements of
installation.
The Clean Air Act 1993 and Smoke Control Areas
“Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a
smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed
boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use
within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls which
generally apply in the smoke control area). The Secretary of State for Environment, Food and Rural Affairs has
powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England.
In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries. Separate
legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern Ireland. Therefore it is a requirement
that fuels burnt or obtained for use in smoke control areas have been "authorised" in Regulations and that
appliances used to burn solid fuel in those areas (other than "authorised" fuels) have been exempted by an Order
made and signed by the Secretary of State or Minister in the devolved administrations. Further information on the
requirements of the Clean Air Act can be found here :
http://smokecontrol.defra.gov.uk/
Your local authority is
responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas
and you can contact them for details of Clean Air Act requirements “
The Ecco Stoves 730EC2 has been
recommended as suitable for use in smoke control areas when burning wood logs with a maximum moisture
content of 20% seasoned wood logs only.